In July of this year, Huawei launched Huawei's newest router product, Huawei Router Q1, and at the same time, it also innovated the concept of “child-mother routingâ€, which was solved by a “mother†of a mother-to-child (standard 1) son-mother router. The Wi-Fi signal coverage problem that would otherwise be able to be solved was due to the need for renovation wiring and the use of multiple routers/APs.
HUAWEI HUAWEI Huawei routing Q1 routing/dual WiFi coverage/wall stabilization/smart home/network security wireless router Jingdong proprietary, Huawei's official son and daughter router, where the signal is not good to insert, son and daughter routing WiFi dual coverage, Solve the problem of large rooms and villas network coverage Reference price:Â¥599
Wherever the signal is not good, put the sub-router on where the power outlet is plugged in, then the Wi-Fi signal in the home can be covered by the whole house, and no longer worry about the Wi-Fi dead angle.
Foreword:Thanks to the popularity of mobile devices such as laptops and smart phones, most home networks now have wireless routers installed to cover 802.11ac wireless LAN signals. With a minimum cost of less than $300, wireless connections up to 867 Mbps or even 1300 Mbps can be achieved.
For a friend who has purchased a large house, it will be even more worrying in the renovation than in the two or three bedrooms below the level of 120. For example, a large 200-square-meter penthouse house will generally have multiple toilets. In multiple living rooms, we will choose to install multiple TV sets and multiple shower heads. Air conditioners are basically installed in each room.
The same signal coverage area and signal strength are the two issues most concerned about when users of large-area houses choose wireless routing. However, even if a router is covered extensively and the signal is strong, there will be a blind spot of the Wi-Fi signal. In particular, a desk, a sofa, a bathroom, a kitchen balcony and the like on the wall are basically the blind spots covered by the home signal.
According to Ah Cai's experience in using wireless devices for many years, the transmission speed of the 802.11ac wireless network is related to the placement of wireless routers, the number of penetrating walls, the transmission distance, whether it is located in a dead space, and the number of Internet-connected devices is closely related. In the same room, ideally, the actual test transmission speed limit of the 867Mbps 802.11n network was only 30-35 Mbytes/sec. from the ideal state that the wireless router was not interfered within a distance of three meters.
The premise of this internet speed is that it cannot be partitioned. According to experience, the partition will cause about half of the transmission speed to drop. What is more bizarre is that the corner of the room is still a mysterious corner of the signal. If the desk is placed in the corner of the room, you will find that the connection speed of the notebook's wireless network card will not reach 54Mbps after the partition.
In this case, no matter how strong a wireless router transmits power, it cannot achieve signal coverage in the entire house. Because China's WLAN national standard stipulates that the maximum signal transmission power of the wireless router must not exceed the national standard (40μW/cm2). Therefore, genuine wireless routers that meet national standards have no way to cover perfect wireless signals within a limited-sized transmit power to a complex multi-building house.
From the conventional renovation idea, it should be the turn of the Gigabit switch/router and twisted pair. The use of the AP mode wireless router as the WIFI signal extension is the best policy. At the same time, we should note that the existence of twisted pair is the stable transmission performance of the Gigabit exclusive bandwidth, but the construction of the domestic Mustang decoration team is uneven. Once the decoration is out of order, if the wiring fails and the Gigabit connection cannot be achieved, then Twisted-pair Ethernet is not as free and convenient as a wireless network, and there is no performance advantage in transmission speed.
The decoration of Ah Cai's new home is a living example of the failure of twisted-pair cable wiring. Dad helped the decoration team to carry out the renovation. As a result, there was no special twisted-pair tester for testing and acceptance. The twisted-pair wire 8p buried in the wall showed a broken core and only passed 7p, resulting in degraded speed reduction to 100BASE-T mode. This is ten times worse than the data transmission speed of an ideal Gigabit twisted-pair network .
Lynx Box M13
Installation Guide>>Huawei Glory Box Pro
Installation Guide>>Millet box 3
Installation Guide>>Infinik i9
Installation Guide>>KKTV
Installation Guide>>Letv TV S50 Air
Installation Guide>>