300V 450/750V Low Voltage Electric Wire Thw/Thhw/Bvr/BV Cable

Model NO.: BV/BVR-030
Material Shape: Round Wire
Range of Application: Flame Retardant
Certification: ISO9001, CE, UL, CCC, RoHS
Brand: Dayuan
Copper Material: Oxygen-Free Copper (99.9% Purity)
Color: Black, Red, Blue, Yellow, Green, White
Standards: IEC 60227, BS 6004, VDE0281, GB/T 5023, Jb/T8734
Voltage: 300/500V,450/750V
Solid or Flexible: Both Ok
Company Nature: Manufacturer and Trading Company
Conductor: Annealed Copper Wires, Solid or Stranded
Item Name: Electrical Wire PVC Insulation BV/Bvr Cable
Features: Flame Retardance, Fire Resistance
Max.Operating Temperature: 70,90,105 Degree
Trademark: Luoyang Dayuan
Transport Package: Sample Roll, Plastic Drum, Ploywood Drum, etc
Specification: 1.5mm2 2.5mm2 4mm2 6mm2 10mm2
Origin: Luoyang, China
HS Code: 85444929
Model NO.: BV/BVR-030
Material Shape: Round Wire
Range of Application: Flame Retardant
Certification: ISO9001, CE, UL, CCC, RoHS
Brand: Dayuan
Copper Material: Oxygen-Free Copper (99.9% Purity)
Color: Black, Red, Blue, Yellow, Green, White
Standards: IEC 60227, BS 6004, VDE0281, GB/T 5023, Jb/T8734
Voltage: 300/500V,450/750V
Solid or Flexible: Both Ok
Company Nature: Manufacturer and Trading Company
Conductor: Annealed Copper Wires, Solid or Stranded
Item Name: Electrical Wire PVC Insulation BV/Bvr Cable
Features: Flame Retardance, Fire Resistance
Max.Operating Temperature: 70,90,105 Degree
Trademark: Luoyang Dayuan
Transport Package: Sample Roll, Plastic Drum, Ploywood Drum, etc
Specification: 1.5mm2 2.5mm2 4mm2 6mm2 10mm2
Origin: Luoyang, China
HS Code: 85444929
Product Description
PVC Insulated BV/BVR House Wiring Electrical Cable
 
Copper core pvc insulasted electric cable is a fine and ideal cable with conductor of plain annealed copper wires,solid or stranded.These cables are used for general purpose,as building wire for power, lighting and control wire to electrical appliances,suitable for use in conduit and for fixed,protected installation. The cable can be of flame ratardance,fire resistance and other property.
 
Type H05V-U, H07V-U, H07V-R, BS6004 6491X, BV, BVR
Voltage Rate 300/500V, 450/750V
Range of Nominal cross section: 0.75 mm2 ~ 630 mm2
Application These cables are used for general purpose, as building wire for power, lighting and control wire to electrical appliances, suitable for use in conduit and for fixed, protected installation.
Standard IEC 60227, BS 6004, VDE0281, GB/T 5023, JB/T8734
Constructions Conductor: Class 1/2 Plain annealed copper wires, solid or stranded
Insulation: PVC
Core color: Red, Brown, Grey, Black, Blue, Green/Yellow or others on request
Max. Operating Temperature 70°C, can be 90°C,105°C as per requirement
Packing 100 meter/roll or as per requirement
Production Capacity 100 kilometer/ day
MOQ 10000 meters for small size, 5000 meters for middle size, 1000 meters for big size
Delivery time 10~15 working days
Remark The cable can be of flame retardance, fire resistance and other property

Technical Information:
1. U0 /U: 300/500V,450/750V
2. Standard Applied: IEC 60227,BS 6004,VDE0281,GB/T 5023,JB/T8734
3. Max.Operating Temperature: 70°C,can be 90°C,105°C as per requirent
4. Conductor:Class 1/2 Plain Annealed copper wire,solid or stranded
5. Insulation:PVC
6.Cores:single core
7.Range of Nominal cross section: 0.75~240sqmm
8. Jacket: without Jacket
9. Color: Black,Brown,Grey,Blue,Green/Yellow or orthers on request
10.Flame ratardance,fire resistance and other property can be available
11.Packing:100 meter/roll or as per requirement
12. Certification: ISO9001,ISO14001,OHSMS18001,CE,CB,CCC,SAA,etc.
13.OME can be available
14.BV cables have very good sales over the world,enjoy ing a very good reputation based on top quality,most competitive price and best service.

Parameter of bv/bvr cable
 
Model Name
BV Copper Core PVC Insulation Wire
BLV Aluminum Core PVC Insulation Wire
BVR Copper Core PVC Insulation Flexible Wire
BVV Copper Core PVC Insulation PVC Sheath Round Wire
BVVB Copper Core PVC Insulation PVC Sheath Flat Wire
BLVVB Aluminum Core PVC Insulation PVC Sheath Flat Wire
BV-90 Copper Core Heat-resistance 105 PVC Insulation

BV cable  of Common wire 
Kindly note that we can make it as your requirement

 BV Cable data 1:
Norminal Sectional area mm2 Conductor No/Dia.mm Nominal Insulated thick mm Max overall Dia.mm Conductor Resistance at 20°C Min insulated resistance at 70MΩ/KM Weight Kg/km
Cu Al Cu Al
1.5 1/1.38 0.7  3.3  12.1 - 0.011  19.2  -
1.5 7/0.52 0.7  3.5  12.1 - 0.010  20.6  -
2.5 1/1.78 0.8  3.9  7.41 11.8 0.010  30.8 15.0 
4 1/2.25 0.8  4.4  4.61 7.39 0.0085 45.5 21.0 
6 1/2.76 0.8  4.9  3.08 4.91 0.0070  65.0  29.0 
10 7/1.35 1.0  7.0  1.83 3.08 0.0065 110.0  52.0 
16 7/1.7 1.0  8.0  1.15 1.91 0.0050  170.0  70.0 
25 7/2.14 1.2  10.0  0.727 1.20  0.0050  270.0  110.0 
35 7/2.52 1.2  11.5  0.524 0.868 0.0040  364.0  150.0 
50 19/1.78 1.4  13.0  0.387 0.641 0.0045 5000.0  200.0 
70 19/2.14 1.4  15.0  0.268 0.443 0.0035 688.0  269.0 
95 19/2.52 1.6  17.5  0.193 0.320  0.0035 953.0  360.0 
120 37/2.03 1.6  19.0  0.153 0.253 0.0032 1168.0  449.0 
150 37/2.25 1.8  21.0  0.124 0.206 0.0032 1466.0  551.0 
185 37/2.52 2.0  32.5  0.099 0.164 0.0032 1808.0  668.0 

 BV/bvr Cable data 2:
Norminal Sectional area mm2 Conductor No/Dia.mm Nominal Insulated thick mm Max overall Dia.mm Conductor Resistance at 20°C Min insulated resistance at 70MΩ/KM Weight Kg/km
2.5 9/0.41 0.8  4.2 7.41 0.011 33.0 
4 19/0.52 0.8  4.8 4.61 0.009 48.0 
6 19/0.64 0.8  5.6 3.08 0.0084 68.0 
10 49/0.64 1.0  7.6 1.83 0.0072 115.0 
16 49/0.64 1.0  8.8 1.15 0.0062 176.0 
25 98/0.58 1.2  11.0  0.727 0.0058 272.0 
35 133/0.58 1.2  12.5 0.524 0.0052 384.0 
50 133/0.68 1.4  16.5 0.387 0.0051 510.0 
70 189/0.68 1.4  16.5 0.268 0.0045 714.0 
95 259/0.68 1.0  19.5 0.139 0.0035 965.0 
120 259/0.76 1.8  22.0  0.153 0.0032 1210.0 

All the goods are full meter and  working life are 25 years!
Company Information
  BV cable  factory and worshop corner 
solar cable have one big workshop about 10,000m2,  our factory is about 61,081m2 with register capital about 540 million. 700 stuff and 40 engineer.  every step is to make sure the delivery time and quality!
 
 
Packaging & Shipping
 
  BV cable  packing, we can also make it as your need for that  we have two professional wooden engineer
 
 
 
Inspection machine
 
BV cable six inspection machine
 
We inspect every product before deliverying the goods to ensure the quality!

Contact
Sarina Ma

Department sale manager
International Trade Department
Luoyang Asian Sun Industrial Group Co., Ltd
=================================
Tel: +86-379-65170063                     
Mobile: + 86-18338892373
Web: http://www.dy-cable.com
Alibaba Showroom: http://dayuancable.en.alibaba.com
================================= Product Description
PVC Insulated BV/BVR House Wiring Electrical Cable
 
Copper core pvc insulasted electric cable is a fine and ideal cable with conductor of plain annealed copper wires,solid or stranded.These cables are used for general purpose,as building wire for power, lighting and control wire to electrical appliances,suitable for use in conduit and for fixed,protected installation. The cable can be of flame ratardance,fire resistance and other property.
 
Type H05V-U, H07V-U, H07V-R, BS6004 6491X, BV, BVR
Voltage Rate 300/500V, 450/750V
Range of Nominal cross section: 0.75 mm2 ~ 630 mm2
Application These cables are used for general purpose, as building wire for power, lighting and control wire to electrical appliances, suitable for use in conduit and for fixed, protected installation.
Standard IEC 60227, BS 6004, VDE0281, GB/T 5023, JB/T8734
Constructions Conductor: Class 1/2 Plain annealed copper wires, solid or stranded
Insulation: PVC
Core color: Red, Brown, Grey, Black, Blue, Green/Yellow or others on request
Max. Operating Temperature 70°C, can be 90°C,105°C as per requirement
Packing 100 meter/roll or as per requirement
Production Capacity 100 kilometer/ day
MOQ 10000 meters for small size, 5000 meters for middle size, 1000 meters for big size
Delivery time 10~15 working days
Remark The cable can be of flame retardance, fire resistance and other property

Technical Information:
1. U0 /U: 300/500V,450/750V
2. Standard Applied: IEC 60227,BS 6004,VDE0281,GB/T 5023,JB/T8734
3. Max.Operating Temperature: 70°C,can be 90°C,105°C as per requirent
4. Conductor:Class 1/2 Plain Annealed copper wire,solid or stranded
5. Insulation:PVC
6.Cores:single core
7.Range of Nominal cross section: 0.75~240sqmm
8. Jacket: without Jacket
9. Color: Black,Brown,Grey,Blue,Green/Yellow or orthers on request
10.Flame ratardance,fire resistance and other property can be available
11.Packing:100 meter/roll or as per requirement
12. Certification: ISO9001,ISO14001,OHSMS18001,CE,CB,CCC,SAA,etc.
13.OME can be available
14.BV cables have very good sales over the world,enjoy ing a very good reputation based on top quality,most competitive price and best service.

Parameter of bv/bvr cable
 
Model Name
BV Copper Core PVC Insulation Wire
BLV Aluminum Core PVC Insulation Wire
BVR Copper Core PVC Insulation Flexible Wire
BVV Copper Core PVC Insulation PVC Sheath Round Wire
BVVB Copper Core PVC Insulation PVC Sheath Flat Wire
BLVVB Aluminum Core PVC Insulation PVC Sheath Flat Wire
BV-90 Copper Core Heat-resistance 105 PVC Insulation

BV cable  of Common wire 
Kindly note that we can make it as your requirement

 BV Cable data 1:
Norminal Sectional area mm2 Conductor No/Dia.mm Nominal Insulated thick mm Max overall Dia.mm Conductor Resistance at 20°C Min insulated resistance at 70MΩ/KM Weight Kg/km
Cu Al Cu Al
1.5 1/1.38 0.7  3.3  12.1 - 0.011  19.2  -
1.5 7/0.52 0.7  3.5  12.1 - 0.010  20.6  -
2.5 1/1.78 0.8  3.9  7.41 11.8 0.010  30.8 15.0 
4 1/2.25 0.8  4.4  4.61 7.39 0.0085 45.5 21.0 
6 1/2.76 0.8  4.9  3.08 4.91 0.0070  65.0  29.0 
10 7/1.35 1.0  7.0  1.83 3.08 0.0065 110.0  52.0 
16 7/1.7 1.0  8.0  1.15 1.91 0.0050  170.0  70.0 
25 7/2.14 1.2  10.0  0.727 1.20  0.0050  270.0  110.0 
35 7/2.52 1.2  11.5  0.524 0.868 0.0040  364.0  150.0 
50 19/1.78 1.4  13.0  0.387 0.641 0.0045 5000.0  200.0 
70 19/2.14 1.4  15.0  0.268 0.443 0.0035 688.0  269.0 
95 19/2.52 1.6  17.5  0.193 0.320  0.0035 953.0  360.0 
120 37/2.03 1.6  19.0  0.153 0.253 0.0032 1168.0  449.0 
150 37/2.25 1.8  21.0  0.124 0.206 0.0032 1466.0  551.0 
185 37/2.52 2.0  32.5  0.099 0.164 0.0032 1808.0  668.0 

 BV/bvr Cable data 2:
Norminal Sectional area mm2 Conductor No/Dia.mm Nominal Insulated thick mm Max overall Dia.mm Conductor Resistance at 20°C Min insulated resistance at 70MΩ/KM Weight Kg/km
2.5 9/0.41 0.8  4.2 7.41 0.011 33.0 
4 19/0.52 0.8  4.8 4.61 0.009 48.0 
6 19/0.64 0.8  5.6 3.08 0.0084 68.0 
10 49/0.64 1.0  7.6 1.83 0.0072 115.0 
16 49/0.64 1.0  8.8 1.15 0.0062 176.0 
25 98/0.58 1.2  11.0  0.727 0.0058 272.0 
35 133/0.58 1.2  12.5 0.524 0.0052 384.0 
50 133/0.68 1.4  16.5 0.387 0.0051 510.0 
70 189/0.68 1.4  16.5 0.268 0.0045 714.0 
95 259/0.68 1.0  19.5 0.139 0.0035 965.0 
120 259/0.76 1.8  22.0  0.153 0.0032 1210.0 

All the goods are full meter and  working life are 25 years!
Company Information
  BV cable  factory and worshop corner 
solar cable have one big workshop about 10,000m2,  our factory is about 61,081m2 with register capital about 540 million. 700 stuff and 40 engineer.  every step is to make sure the delivery time and quality!
 
 
Packaging & Shipping
 
  BV cable  packing, we can also make it as your need for that  we have two professional wooden engineer
 
 
 
Inspection machine
 
BV cable six inspection machine
 
We inspect every product before deliverying the goods to ensure the quality!

Contact
Sarina Ma

Department sale manager
International Trade Department
Luoyang Asian Sun Industrial Group Co., Ltd
=================================
Tel: +86-379-65170063                     
Mobile: + 86-18338892373
Web: http://www.dy-cable.com
Alibaba Showroom: http://dayuancable.en.alibaba.com
=================================

Supply Various Printer Accessories Such as Stencil Cleaning Wipes, Stencil Rolls for PCB Printers, 

Stencil wiping cloth, Printer Metallic Squeegee, Squeegee Blade, MPM Metallic Squeege, DEK Priter 

parts, DEK 300MM 6 holes Squeegee Blade, GKG 450MM Squeegee, GKG 520MM Squeegee, PCB 

Supporting Holder, Printer Thimble etc, 

Pcb Printer Accessories

Pcb Printer Accessories,Metal Hand Held Squeegee,Solder Paste Knife,Samsung Camera Pcb Board

Guangdong Juguangheng Automation Equipment Co.,Ltd. , http://www.smtsupplier.net

Posted on