60FT 18m Galvanized Polygon Electric Steel Pole

Model NO.: FT00047
Structure: B Type
Name: 60FT 18m Galvanized Polygon Electric Steel Pole
Thickness: 2-25mm
Yield Strength: 235MPa-345MPa
Galvanized Standard: ASTM A123 En BS 1406
Material: Q235B Q345b Gr50 Gr65 S355jo/Jr
Top Tension Load: 400dan 600dan 800dan or as Per Design
Vottage: 11kv 33kv 35kv 69kv 138kv or More
Height: 8m-60m
Shape: Octagonal Polygon
Pole Type: Support Pole Tension Pole Angle Pole Terminal Pole
Trademark: FUTAO
Transport Package: Wrap Bubbles or Old Blanket Cover Pole Top and Bot
Specification: 11kv 33kv Octagonal Power Pole with Galvanized
Origin: China
HS Code: 73089
Model NO.: FT00047
Structure: B Type
Name: 60FT 18m Galvanized Polygon Electric Steel Pole
Thickness: 2-25mm
Yield Strength: 235MPa-345MPa
Galvanized Standard: ASTM A123 En BS 1406
Material: Q235B Q345b Gr50 Gr65 S355jo/Jr
Top Tension Load: 400dan 600dan 800dan or as Per Design
Vottage: 11kv 33kv 35kv 69kv 138kv or More
Height: 8m-60m
Shape: Octagonal Polygon
Pole Type: Support Pole Tension Pole Angle Pole Terminal Pole
Trademark: FUTAO
Transport Package: Wrap Bubbles or Old Blanket Cover Pole Top and Bot
Specification: 11kv 33kv Octagonal Power Pole with Galvanized
Origin: China
HS Code: 73089
60FT 18M Galvanized Polygon Electric Steel Pole
product name 60FT 18M Galvanized Polygon Electric Steel Pole
Place of Origin Jiangsu, China (Mainland)
Brand Name   FU TAO
Material  Steel
Type Round OR Polygonal
Material Hot roll Steel Q235,345,A36,GR50
APPLICATIOL Electricity distribution
Surface treat  Hot-dip-galvanized 
Thickness  2.5mm-20mm
Certificate ISO9001:2000
Wind Speed  160KM/H or as per clients provide

60FT 18m Galvanized Polygon Electric Steel Pole
Company information
Our company has a lot of experience in design and production.Possess american PLS-Pole software .The company main products are Electric steel pole,High mast lighting pole,Communication tower,lamp pole etc.the company is equipped with advanced manufacturing facilities.We own a Belgium LVD company large-sized numerical control hydraulic pressure folding machine with once folding length 16,000mm and the thickness 2-25mm. We also equipped with a series of numerical control conveyor systems of flattening, cutting, folding and auto-welding ,annual output has reached 20000tons Our manufacturing process has been ISO9001:2000 certified, our company products quality have a good reputation in the world.
60FT 18m Galvanized Polygon Electric Steel Pole

Producing process
60FT 18m Galvanized Polygon Electric Steel Pole

Galvanized process

60FT 18m Galvanized Polygon Electric Steel Pole
LIST OF MAJOR VENDORS AND SUBCONTRACTORS OF FUTAO
Name of Supplier Scope of supply Procedures to ensure quality
Bao steel Steel Coil and plate ★Quality Inspector and Warehousesupervisor will check the surface of steel coil/plate
★ Quality Inspector will check the Mill Certificate of the steel material and prepare the test sample
★ Quality Department will make a chemical and Machinery test.
★ Check the test record with mill certificate and client required stardand
Tai Yuan steel Steel coil and plate
  1. Same process as above
Wuhan Iron&Steel Steel coil and plate
  1. Same process as above
Welding material   ★ Quality department will check Certification of material before they delivery
★ Quality Inspector/warehouse will check again and prepare the test sample as Random
★ Quality department make a test for sample. If pass confirm with Purchasing Department.
  Bolts,Nuts,Hardware and Anchor bolts ★ Quality Department check the certificate before receiving
★ Send sample to test lab and get report.
★ Reject if a sample test fails
Daiping Galvanizing Co.,Ltd. Hot-dip-galvanizing
  1. Futao inspectors will check surface looking
  2. Check Zinc thickness of each pole after galvanizing base on required stardand

Packing And Delivery
60FT 18m Galvanized Polygon Electric Steel Pole
FAQ
1. Price Term: FOB, CFR or CIF.The price includes pole shaft, based plate, cross arm and anchor part.
Shipping seaport: Shanghai Seaport. For FOB, CFR or CIF price, please specify which exact model you need, then tell us quantity of your order so that we can calculate the local transport charge and sea freight.
2. MOQ: 1 set for Customized
3. Payment: Typically 30% by T/T as a deposit, balance by T/T or L/C at sight before shipment. Other payment way can be negotiated.
4. Delivery time : 60FT 18M Galvanized Polygon Electric Steel Pole can be ready for shipment within 10 workdays after receiving deposit.
5 Warranty : 20 years
6.Surface treatment :hot dip galvanization
Application: Electric Transmission

Our Service60FT 18m Galvanized Polygon Electric Steel Pole
Our Service
1.Reply your inquiry in 24 working hours.
2. Experienced staffs answer all your questions in fluent English.
3. Customized design is available. UEM&UBM are welcomed.
4. Exclusive and unique solution can be provided to our customer by our well-trained and professional engineers and staff.
5. Special discount and protection of sales are provided to our distributor.
6. Professional factory : We are manufacturer, specializing in producing all kinds of steel poles for more than 20 years,competitive with good quantity.
7 Sample: We can send out sample for test in one week if the order quantity is big enough. But the shipment charges is usually paid by your side, the charges will be rebounded when we have formal order.
8. As an honest seller, we always use superior raw material, advanced machines, skilled technicians to ensure our products to be finished in high quality and stable feature. Welcome to contact us or visit our company.
 


















 
60FT 18M Galvanized Polygon Electric Steel Pole
product name 60FT 18M Galvanized Polygon Electric Steel Pole
Place of Origin Jiangsu, China (Mainland)
Brand Name   FU TAO
Material  Steel
Type Round OR Polygonal
Material Hot roll Steel Q235,345,A36,GR50
APPLICATIOL Electricity distribution
Surface treat  Hot-dip-galvanized 
Thickness  2.5mm-20mm
Certificate ISO9001:2000
Wind Speed  160KM/H or as per clients provide

60FT 18m Galvanized Polygon Electric Steel Pole
Company information
Our company has a lot of experience in design and production.Possess american PLS-Pole software .The company main products are Electric steel pole,High mast lighting pole,Communication tower,lamp pole etc.the company is equipped with advanced manufacturing facilities.We own a Belgium LVD company large-sized numerical control hydraulic pressure folding machine with once folding length 16,000mm and the thickness 2-25mm. We also equipped with a series of numerical control conveyor systems of flattening, cutting, folding and auto-welding ,annual output has reached 20000tons Our manufacturing process has been ISO9001:2000 certified, our company products quality have a good reputation in the world.
60FT 18m Galvanized Polygon Electric Steel Pole

Producing process
60FT 18m Galvanized Polygon Electric Steel Pole

Galvanized process

60FT 18m Galvanized Polygon Electric Steel Pole
LIST OF MAJOR VENDORS AND SUBCONTRACTORS OF FUTAO
Name of Supplier Scope of supply Procedures to ensure quality
Bao steel Steel Coil and plate ★Quality Inspector and Warehousesupervisor will check the surface of steel coil/plate
★ Quality Inspector will check the Mill Certificate of the steel material and prepare the test sample
★ Quality Department will make a chemical and Machinery test.
★ Check the test record with mill certificate and client required stardand
Tai Yuan steel Steel coil and plate
  1. Same process as above
Wuhan Iron&Steel Steel coil and plate
  1. Same process as above
Welding material   ★ Quality department will check Certification of material before they delivery
★ Quality Inspector/warehouse will check again and prepare the test sample as Random
★ Quality department make a test for sample. If pass confirm with Purchasing Department.
  Bolts,Nuts,Hardware and Anchor bolts ★ Quality Department check the certificate before receiving
★ Send sample to test lab and get report.
★ Reject if a sample test fails
Daiping Galvanizing Co.,Ltd. Hot-dip-galvanizing
  1. Futao inspectors will check surface looking
  2. Check Zinc thickness of each pole after galvanizing base on required stardand

Packing And Delivery
60FT 18m Galvanized Polygon Electric Steel Pole
FAQ
1. Price Term: FOB, CFR or CIF.The price includes pole shaft, based plate, cross arm and anchor part.
Shipping seaport: Shanghai Seaport. For FOB, CFR or CIF price, please specify which exact model you need, then tell us quantity of your order so that we can calculate the local transport charge and sea freight.
2. MOQ: 1 set for Customized
3. Payment: Typically 30% by T/T as a deposit, balance by T/T or L/C at sight before shipment. Other payment way can be negotiated.
4. Delivery time : 60FT 18M Galvanized Polygon Electric Steel Pole can be ready for shipment within 10 workdays after receiving deposit.
5 Warranty : 20 years
6.Surface treatment :hot dip galvanization
Application: Electric Transmission

Our Service60FT 18m Galvanized Polygon Electric Steel Pole
Our Service
1.Reply your inquiry in 24 working hours.
2. Experienced staffs answer all your questions in fluent English.
3. Customized design is available. UEM&UBM are welcomed.
4. Exclusive and unique solution can be provided to our customer by our well-trained and professional engineers and staff.
5. Special discount and protection of sales are provided to our distributor.
6. Professional factory : We are manufacturer, specializing in producing all kinds of steel poles for more than 20 years,competitive with good quantity.
7 Sample: We can send out sample for test in one week if the order quantity is big enough. But the shipment charges is usually paid by your side, the charges will be rebounded when we have formal order.
8. As an honest seller, we always use superior raw material, advanced machines, skilled technicians to ensure our products to be finished in high quality and stable feature. Welcome to contact us or visit our company.
 


















 

Not Group

Vortex Pumps,Vortex Pumps South Africa,Vortex Pumps Australia,Vortex Pumps Germany

Vortex Pumps,Jet Pumps Co., Ltd. , http://www.nbsubmersiblepumps.com

Posted on