Cast Iron Used Street Light Poles

Input Voltage: 220v
With Light Source: With Light Source
LED Chips Brand: as Customer′s Requirement
Operating Temp.: - 30°c to 60°c
LED Life Span: More Than 60000h
Wind Resistance: 160km/H
Surface Treatment: Hot DIP Galvanised, Spray
Color: as Customer′s Requirement
Thickness: 2.5-5mm
Height: 3-15m or as Customer′s Requirement
Shape: Round, Conical, Hexagonal, Octagonal, Polygonal
Arm Length: 1-3m
Standard: ISO 9001
Trademark: Borui
Transport Package: Woven Bag, Nylon, Plastic Bubble Paper, Felt etc.
Specification: steel Q235, Q354
Origin: Yangzhou, Jiangsu
HS Code: 73089000
Input Voltage: 220v
With Light Source: With Light Source
LED Chips Brand: as Customer′s Requirement
Operating Temp.: - 30°c to 60°c
LED Life Span: More Than 60000h
Wind Resistance: 160km/H
Surface Treatment: Hot DIP Galvanised, Spray
Color: as Customer′s Requirement
Thickness: 2.5-5mm
Height: 3-15m or as Customer′s Requirement
Shape: Round, Conical, Hexagonal, Octagonal, Polygonal
Arm Length: 1-3m
Standard: ISO 9001
Trademark: Borui
Transport Package: Woven Bag, Nylon, Plastic Bubble Paper, Felt etc.
Specification: steel Q235, Q354
Origin: Yangzhou, Jiangsu
HS Code: 73089000
Yangzhou Borui Electric Lighting Co., Ltd.
steel residential yard square pathway lamp post is suitable for street, road, high way, squares, schools, parks, gardens, residential areas, outdoor lighting plant,  etc.
Cast Iron Used Street Light Poles
Specification introduction
steel residential yard square pathway lamp post
 

Pole 

height 3-15m or more/Q235 Q345 seamless steel/hot dip galvanizing and spraying  powder/ parameters vary according to models , the colour can choose freely as the colour card
light sources Operating Temperature -40°C~75°C , LED Chip BRIDGELUX / Cree ,≥60000H life span
other accessories nuts,screw,bolts fixed mount,wrie,embedded parts,flange
working time 8-12hours/day
working temp & wind resistance - 30°C-60°C & - ≥136km/H
packages nylon,woven bag,foam or plastic bubble.and we also can packed as your demands.
 

Production Process
steel residential yard square pathway lamp post
Raw material test → Cutting →Molding or bending →Welidng (longitudinal )→Dimension verify
→Flange welding →Hole drilling →Calibration → Deburr→Galvanization or powder coating ,painting →Recalibration →Thread →Packages
Cast Iron Used Street Light Poles

Factory Show
Cast Iron Used Street Light Poles

Contact Us: 
Tel: 86-532-83978013
Fax: 86-532-83978023
Mob: 86-15192600825
  
  

Material:

1. All of our material are purchased from famous mill factory to assure the quality.
2. A mill certificate issued by the mill factory with stamp and signature must be provided before unload the material in our factory ,otherwise we have our reason to refuse the material .
3. Before put into production ,all the material must pass the chemical and physical analysis to make sure that they have meet the requested strength and component.


Design and Details

1. Pole,base plate and under ground fixture can be specially made as required.
2.The product has many types , which can meet different requirements of consumers,but the price and some technical specifications can vary greatly.
3. All the photographs are for reference only,and the actual products may vary from the photographs.
4. Lofting and design software :We have steel pole design software which can help us design all kinds of steel pole ,at the same time ,the TMA and LMA are adopted by us to provide the design the drawing accuratly.
 

Inspection:

1. Management team : We have employed years of experience engineers to take charge of the overall managemnt ,especailly the technical managemnt and quality management .
2. Introducing ISO management ,We are awared TUV CE UL certificate . 
3. QC Inpection:It is our company policy that all the finish product should be inspected by our specialzed QC in every manufacure steps and beofore the shipment.


Service: 

1. Reply your inquiry in 12 working hours.
2. Experienced staffs answer all your questions in fluent English.
3. Customized design is available. 4. Exclusive and unique solution can be provided to our customer by our well-trained and professional engineers and staff.
5. Special discount and protection of sales are provided to our distributor.
6. Professional factory : We are manufacturer, specializing in producing all kinds of steel poles for more than 15years, competitive with good quantity.

7 Sample: We can send out sample for test in one week if the order quantity is big enough. But the shipment charges is usually paid by your side, the charges will be rebounded when we have formal order.

8. As an honest seller, we always use superior raw material, advanced machines, skilled technicians to ensure our products to be finished in high quality and stable feature. Welcome to contact us or visit our company.

If you are in need of our products, you may let us know and we will offer you good products with great quality and service.

FAQ:

Q1: Can I have a sample order for lighting pole? 
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q2. What about the lead time?
A :Sample needs 3-5 days, mass production time needs 1-2 weeks for order. 
Q3. Do you have any MOQ limit for lighting pole order?
 A: Yes, MOQ: 1pcs.
Q4. How do you ship the goods and how long does it take to arrive?
 A: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.
Q5. How to proceed an order for lighting pole ?
A: Firstly let us know your requirements or application.Secondly We quote according to your requirements or our suggestions.Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.

Q6. Is it OK to print my logo on led lighting pole product?
 A: Yes. Please inform us formally before our production and confirm the design firstly based on our sample.
Q7: Do you offer guarantee for the products?
A: Yes, we offer 15 years warranty to lighting poles. 
Q8: How to deal with the faulty?
A: Firstly, Our products are produced in strict quality control system and the defective rate will be less
than 0.2%.Secondly, during the guarantee period, we will send new lights with new order for small quantity. For
defective batch products, we will repair them and resend them to you or we can discuss the solution i
ncluding re-call according to real situation.
Yangzhou Borui Electric Lighting Co., Ltd.
steel residential yard square pathway lamp post is suitable for street, road, high way, squares, schools, parks, gardens, residential areas, outdoor lighting plant,  etc.
Cast Iron Used Street Light Poles
Specification introduction
steel residential yard square pathway lamp post
 

Pole 

height 3-15m or more/Q235 Q345 seamless steel/hot dip galvanizing and spraying  powder/ parameters vary according to models , the colour can choose freely as the colour card
light sources Operating Temperature -40°C~75°C , LED Chip BRIDGELUX / Cree ,≥60000H life span
other accessories nuts,screw,bolts fixed mount,wrie,embedded parts,flange
working time 8-12hours/day
working temp & wind resistance - 30°C-60°C & - ≥136km/H
packages nylon,woven bag,foam or plastic bubble.and we also can packed as your demands.
 

Production Process
steel residential yard square pathway lamp post
Raw material test → Cutting →Molding or bending →Welidng (longitudinal )→Dimension verify
→Flange welding →Hole drilling →Calibration → Deburr→Galvanization or powder coating ,painting →Recalibration →Thread →Packages
Cast Iron Used Street Light Poles

Factory Show
Cast Iron Used Street Light Poles

Contact Us: 
Tel: 86-532-83978013
Fax: 86-532-83978023
Mob: 86-15192600825
  
  

Material:

1. All of our material are purchased from famous mill factory to assure the quality.
2. A mill certificate issued by the mill factory with stamp and signature must be provided before unload the material in our factory ,otherwise we have our reason to refuse the material .
3. Before put into production ,all the material must pass the chemical and physical analysis to make sure that they have meet the requested strength and component.


Design and Details

1. Pole,base plate and under ground fixture can be specially made as required.
2.The product has many types , which can meet different requirements of consumers,but the price and some technical specifications can vary greatly.
3. All the photographs are for reference only,and the actual products may vary from the photographs.
4. Lofting and design software :We have steel pole design software which can help us design all kinds of steel pole ,at the same time ,the TMA and LMA are adopted by us to provide the design the drawing accuratly.
 

Inspection:

1. Management team : We have employed years of experience engineers to take charge of the overall managemnt ,especailly the technical managemnt and quality management .
2. Introducing ISO management ,We are awared TUV CE UL certificate . 
3. QC Inpection:It is our company policy that all the finish product should be inspected by our specialzed QC in every manufacure steps and beofore the shipment.


Service: 

1. Reply your inquiry in 12 working hours.
2. Experienced staffs answer all your questions in fluent English.
3. Customized design is available. 4. Exclusive and unique solution can be provided to our customer by our well-trained and professional engineers and staff.
5. Special discount and protection of sales are provided to our distributor.
6. Professional factory : We are manufacturer, specializing in producing all kinds of steel poles for more than 15years, competitive with good quantity.

7 Sample: We can send out sample for test in one week if the order quantity is big enough. But the shipment charges is usually paid by your side, the charges will be rebounded when we have formal order.

8. As an honest seller, we always use superior raw material, advanced machines, skilled technicians to ensure our products to be finished in high quality and stable feature. Welcome to contact us or visit our company.

If you are in need of our products, you may let us know and we will offer you good products with great quality and service.

FAQ:

Q1: Can I have a sample order for lighting pole? 
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q2. What about the lead time?
A :Sample needs 3-5 days, mass production time needs 1-2 weeks for order. 
Q3. Do you have any MOQ limit for lighting pole order?
 A: Yes, MOQ: 1pcs.
Q4. How do you ship the goods and how long does it take to arrive?
 A: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.
Q5. How to proceed an order for lighting pole ?
A: Firstly let us know your requirements or application.Secondly We quote according to your requirements or our suggestions.Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.

Q6. Is it OK to print my logo on led lighting pole product?
 A: Yes. Please inform us formally before our production and confirm the design firstly based on our sample.
Q7: Do you offer guarantee for the products?
A: Yes, we offer 15 years warranty to lighting poles. 
Q8: How to deal with the faulty?
A: Firstly, Our products are produced in strict quality control system and the defective rate will be less
than 0.2%.Secondly, during the guarantee period, we will send new lights with new order for small quantity. For
defective batch products, we will repair them and resend them to you or we can discuss the solution i
ncluding re-call according to real situation.

USB Flash Drive

We are manufacturer/supplier of USB flash drive from China,who offer 100% real original capacity to the world buyers.You can get high quality of USB flash drive from us with custom logo,and also help you build your own brand of USB flash drive 2.0 3.0 with reputation.Capacity from 2MB,8MB,64MB,128MB to 8GB 16GB 32GB 64GB 128GB and 256GB(Biggest real capacity can be 512GB).We mainly offer OEM /ODM service,and offer USB flash drive without logo or with your logos.

Usb Flash Memory,Usb Flash Drive 32Gb,Usb Flash Drive Custom,Usb Flash Drive 3.0,USB Disk,Pendrive,USB key

Shenzhen Konchang Electronic Technology Co.,Ltd , https://www.konchangs.com

Posted on