High-Mast Pole Street Light Outdoor Lighting with Lift Type High Mast Pole Lamp

Model NO.: HM-C001
IP Rating: IP67
Certification: CCC, CE, CQC, EMC, Energy Star, RoHS
Input Voltage: 220V
LED Chips Brand: Bridgelux
Customizable: Custom Made
OEM/ODM: Available
Pole: 20m/45m/Custom Made
Automatic Lifting Setting: Yes or Custom Made
Climbing Ladder: Yes
Material: The Lamp Post Is Q235.
Spec.: LED Flood Light, High Pressure Sodium Lamp
Lamp Material: Die-Casting Aluminum
Trademark: FLOHAR
Transport Package: Bubble Pack, Non-Woven Fabric
Origin: China
HS Code: 9405409000
Model NO.: HM-C001
IP Rating: IP67
Certification: CCC, CE, CQC, EMC, Energy Star, RoHS
Input Voltage: 220V
LED Chips Brand: Bridgelux
Customizable: Custom Made
OEM/ODM: Available
Pole: 20m/45m/Custom Made
Automatic Lifting Setting: Yes or Custom Made
Climbing Ladder: Yes
Material: The Lamp Post Is Q235.
Spec.: LED Flood Light, High Pressure Sodium Lamp
Lamp Material: Die-Casting Aluminum
Trademark: FLOHAR
Transport Package: Bubble Pack, Non-Woven Fabric
Origin: China
HS Code: 9405409000

Product Description

high-mast pole street light outdoor lighting with Lift type high mast pole lamp

High-Mast Pole Street Light Outdoor Lighting with Lift Type High Mast Pole Lamp

Technical Parameter

 

Height From 15 m to 45m
Suit for  Airport ,seaport,plaza,stadium ,square,highway station,street way ,etc
Shape  Round or polygon
Material Q345B/A572,minimum yield strength>=345n/mm2 Q235B/A36,minimum yield strength>=235n/mm2
Torrance of dimension -0.02
Lighting source 400W~2000W high pressure sodium flood light, LED flood light, metal halide light
Lamp plate Various figure of selection ,material with hot dip galvanization steel frame
Lifting system  Lifter fixed in the inner of the pole with lifting speed of 3~5 meter per minute,Equipped e;antiferromagnetism brake and break -proof device,manual operation applied under power cut
Electric appliance control device Electric appliance box to be be the hold of the pole ,lifting operation could be 5 meter away from the pole through wire .Time control and light control could be equipped to realize full-load lighting mode and part lighting mode
Surface treatment  Hot dip galvanized Following ASTM A 123, color polyester power or any other standard by client required
Joint of poles Insert mode,inner flange mode,face to face joint mode
Design of pole Against earthquake of 8 grade
Wind Speed  150KM/H
Thickness  6mm/8mm/10mm

 

Lifting system

  • Latch barrel with inner mounting bracket locker is mounted to an underside of the mast-top pulley assembly. Furthermore, all steel cables are not exposed and more effectively protected. 
  • Latching mechanism latched on steering arms is able to release strain on steel cables when in the operation position. The process of latching on and off is stable and without vibration.
  • The bumper is designed on the luminary mounting bracket for avoiding direct damage between mast-top assembly and the raising luminary mounting bracket.
  • The leveling device for luminary support bracket is easy to operate and convenient to adjust level.

    Special designed red-flag indicator has obvious visual effects and reflects actual situation of latching operation.

Product Structure

High-Mast Pole Street Light Outdoor Lighting with Lift Type High Mast Pole Lamp

Detailed Components

High-Mast Pole Street Light Outdoor Lighting with Lift Type High Mast Pole Lamp

Installation Processs 

High-Mast Pole Street Light Outdoor Lighting with Lift Type High Mast Pole Lamp

Packing and Shipping

High-Mast Pole Street Light Outdoor Lighting with Lift Type High Mast Pole Lamp


Payment Terms

 

T/T

EXW 30% T/T in advance, pay the balance before shipment
FOB
CNF 30% T/T in advance, pay the balance against copy of B/L
CIF
L/C Above USD 50,000, we can accept L/C at sight
Western Union Lower than USD 50,000
PayPal

 

Welcome to use Trade Assurance, you will enjoy:

  • 100% product quality protection
  • 100% on-time shipment protection
  • 100% payment protection for your covered amount

Company Profile


Jiangsu Flohar Lamps Manufacturing Co., Ltd. is the first provincial-level road lighting engineering design and installation enterprise in the region. Since its inception in 1995, the company has always been in the forefront of the industry, making efforts to create a "Flohar" brand and making new breakthroughs in its growth and development. Our main products: LED street lights, Solar street lights, Intelligent street light, High-pole lamp, Landscape lamp and Solar photovoltaic power station. With more than 20 years of unremitting efforts and continuous pioneering efforts, It is the first to obtain ISO9001 international quality system certification, ISO14001 international environmental system certification, China environmental protection product certification certificate, 3C, CE, CQC, RoHS and a series of management system certification certificates and product inspection reports and other product certification certificates. 

Our tenet is: Client foremost, credit first, quality first.

High-Mast Pole Street Light Outdoor Lighting with Lift Type High Mast Pole Lamp
 

Product Description

high-mast pole street light outdoor lighting with Lift type high mast pole lamp

High-Mast Pole Street Light Outdoor Lighting with Lift Type High Mast Pole Lamp

Technical Parameter

 

Height From 15 m to 45m
Suit for  Airport ,seaport,plaza,stadium ,square,highway station,street way ,etc
Shape  Round or polygon
Material Q345B/A572,minimum yield strength>=345n/mm2 Q235B/A36,minimum yield strength>=235n/mm2
Torrance of dimension -0.02
Lighting source 400W~2000W high pressure sodium flood light, LED flood light, metal halide light
Lamp plate Various figure of selection ,material with hot dip galvanization steel frame
Lifting system  Lifter fixed in the inner of the pole with lifting speed of 3~5 meter per minute,Equipped e;antiferromagnetism brake and break -proof device,manual operation applied under power cut
Electric appliance control device Electric appliance box to be be the hold of the pole ,lifting operation could be 5 meter away from the pole through wire .Time control and light control could be equipped to realize full-load lighting mode and part lighting mode
Surface treatment  Hot dip galvanized Following ASTM A 123, color polyester power or any other standard by client required
Joint of poles Insert mode,inner flange mode,face to face joint mode
Design of pole Against earthquake of 8 grade
Wind Speed  150KM/H
Thickness  6mm/8mm/10mm

 

Lifting system

  • Latch barrel with inner mounting bracket locker is mounted to an underside of the mast-top pulley assembly. Furthermore, all steel cables are not exposed and more effectively protected. 
  • Latching mechanism latched on steering arms is able to release strain on steel cables when in the operation position. The process of latching on and off is stable and without vibration.
  • The bumper is designed on the luminary mounting bracket for avoiding direct damage between mast-top assembly and the raising luminary mounting bracket.
  • The leveling device for luminary support bracket is easy to operate and convenient to adjust level.

    Special designed red-flag indicator has obvious visual effects and reflects actual situation of latching operation.

Product Structure

High-Mast Pole Street Light Outdoor Lighting with Lift Type High Mast Pole Lamp

Detailed Components

High-Mast Pole Street Light Outdoor Lighting with Lift Type High Mast Pole Lamp

Installation Processs 

High-Mast Pole Street Light Outdoor Lighting with Lift Type High Mast Pole Lamp

Packing and Shipping

High-Mast Pole Street Light Outdoor Lighting with Lift Type High Mast Pole Lamp


Payment Terms

 

T/T

EXW 30% T/T in advance, pay the balance before shipment
FOB
CNF 30% T/T in advance, pay the balance against copy of B/L
CIF
L/C Above USD 50,000, we can accept L/C at sight
Western Union Lower than USD 50,000
PayPal

 

Welcome to use Trade Assurance, you will enjoy:

  • 100% product quality protection
  • 100% on-time shipment protection
  • 100% payment protection for your covered amount

Company Profile


Jiangsu Flohar Lamps Manufacturing Co., Ltd. is the first provincial-level road lighting engineering design and installation enterprise in the region. Since its inception in 1995, the company has always been in the forefront of the industry, making efforts to create a "Flohar" brand and making new breakthroughs in its growth and development. Our main products: LED street lights, Solar street lights, Intelligent street light, High-pole lamp, Landscape lamp and Solar photovoltaic power station. With more than 20 years of unremitting efforts and continuous pioneering efforts, It is the first to obtain ISO9001 international quality system certification, ISO14001 international environmental system certification, China environmental protection product certification certificate, 3C, CE, CQC, RoHS and a series of management system certification certificates and product inspection reports and other product certification certificates. 

Our tenet is: Client foremost, credit first, quality first.

High-Mast Pole Street Light Outdoor Lighting with Lift Type High Mast Pole Lamp
 

Hanukkah Candle sell very well for Israel ,Color Hanukkah Candle have six colors . it is very small and thin. Small Size Hanukkah Candle is 3.8g . the Dia of Decorative Hanukkah Candle is 0.8cm  Length is about 9.5cm . Customer can do own brand and packages . the design is free . Israel celebrates light with candles, dedicated to festivals.  Hanukkah Candle's Sample is free, you just need to pay the express fee. The feature of Small Size Hanukkah Candle is no smoking ,no drippless,no scented .the materails is 100%paraffin wax . The package of Color Hanukkah Candle is 44pcs/box 50boxes/ctn or can as your package.

Waiting for you 

Hanukkah Candle

Hanukkah Candle,Color Hanukkah Candle,Small Size Hanukkah Candle,Decorative Hanukkah Candle

Shijiazhuang Zhongya Candle Co,. Ltd. , http://www.zycandlefactory.com

Posted on