Original Meanwell Cen-60 Series Single Output Waterproof IP66 LED Driver

  • Model NO.: CEN-60
  • Output Type: DC
  • Color: White
  • Internal Structure: On-Off Type
  • Connection: Screw
  • Brand: Meanwell
  • Trademark: Meanwell
  • Specification: Universal
  • HS Code: 8504401400
  • Usage: Laptop, Switching, Mobile Phone, Game Player, Digital Camera, Phone, Display, Led Strip
  • Certification: TUV, RoHS, UL, ISO9001, CCC
  • Type: OEM
  • Power Source: Full-Bridge Type
  • Bluetooth Standard: 1.1
  • Size: 185*62.5*40.5mm
  • Transport Package: Paper Carton
  • Origin: Guangdong China (Mainland)

Original Meanwell CEN-60 Series Single Output Waterproof IP66 LED Driver Features:

1. Universal AC input / Full range (up to 295VAC)
2. Protections: Short circuit / Over current / Over voltage / Over temperature
3. Output voltage and constant current level adjustable
4. Built-in active PFC function
5. IP66 design for indoor or outdoor installations
6. Class 2 power unit
7. Cooling by free air convection
8. 100% full load burn-in test
9. High reliability                        
10. Suitable for LED lighting and moving sign applications
11. Compliance to worldwide safety regulations for lighting
12. Suitable for dry / damp / wet locations
13. 3 years warranty


Original Meanwell CEN-60 Series Single Output Waterproof IP66 LED Driver Specifications:
 
MODEL CEN-60-12 CEN-60-15 CEN-60-20 CEN-60-24 CEN-60-30 CEN-60-36 CEN-60-42 CEN-60-48 CEN-60-54
OUTPUT DC VOLTAGE 12V 15V 20V 24V 30V 36V 42V 48V 54V
CONSTANT CURRENT REGION Note.5 9 ~ 12V 11.25 ~ 15V 15 ~ 20V 18 ~ 24V 22.5 ~ 30V 27 ~ 36V 31.5 ~ 42V 36 ~ 48V 40.5 ~ 54V
RATED CURRENT 5A 4A 3A 2.5A 2A 1.7A 1.45A 1.3A 1.15A
CURRENT RANGE 0 ~ 5A 0 ~ 4A 0 ~ 3A 0 ~ 2.5A 0 ~ 2A 0 ~ 1.7A 0 ~ 1.45A 0 ~ 1.3A 0 ~ 1.15A
RATED POWER 60W 60W 60W 60W 60W 61.2W 60.9W 62.4W 62.1W
RIPPLE & NOISE (max.) Note.2 2Vp-p 2.4Vp-p 1.8Vp-p 2.4Vp-p 3Vp-p 3.6Vp-p 4Vp-p 4.6Vp-p 5Vp-p
VOLTAGE ADJ. RANGE (SVR1) 10.8 ~ 13.5V 13.5 ~ 17V 17 ~ 22V 22 ~ 27V 27 ~ 33V 33 ~ 40V 37 ~ 46V 43 ~ 53V 49 ~ 58V
CURRENT ADJ. RANGE(SVR2) 3.75 ~ 5A 3 ~ 4A 2.3 ~ 3A 1.9 ~ 2.5A 1.5 ~ 2A 1.3 ~ 1.7A 1.1 ~ 1.45A 1 ~ 1.3A 0.9 ~ 1.15A
VOLTAGE TOLERANCE Note.3 ±10%
LINE REGULATION ±3.0%
LOAD REGULATION ±5.0%
SETUP TIME 500ms / 230VAC 1200ms / 115VAC at full load
INPUT VOLTAGE RANGE        Note.4 90 ~ 295VAC    127 ~ 417VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.97/115VAC, PF>0.95/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION THD< 20% when output loading>=75% at 115VAC/230VAC input and output loading>=80% at 277VAC input
EFFICIENCY (Typ.) 86% 87% 88% 89% 90% 90% 90% 91% 91%
AC CURRENT (Typ.) 0.8A/115VAC    0.4A/230VAC    0.3A/277VAC
INRUSH CURRENT (Typ.) COLD START 45A(twidth=85μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT <0.75mA / 240VAC
PROTECTION OVER CURRENT 95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 14.5 ~ 17V 17.5 ~ 21V 22.8 ~ 26V 28 ~ 34V 34 ~ 38V 41 ~ 46V 47 ~ 52V 54 ~ 60V 59 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -30 ~ +70ºC (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +80ºC, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/ºC (0 ~ 50ºC)
VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &
EMC
SAFETY STANDARDS UL879, UL8750, CSA C22.2 No. 207-M89, CSA C22.2 No. 250.0-08, TUV EN61347-1, EN61347-2-13, IP66, J61347-1, J61347-2-13 approved
WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/ 70% RH
EMC EMISSION Compliance to EN55015, EN61000-3-2 Class C (>=75% load) ; EN61000-3-3
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria B
OTHERS MTBF 523.4Khrs min.  MIL-HDBK-217F (25ºC)
DIMENSION 185*62.5*40.5mm (L*W*H)
PACKING 0.6Kg;24pcs/15.4Kg/1.29CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Please refer to "DRIVING METHODS OF LED MODULE".
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
 
 
 

Recess Mounted Led Profile

 

Recess Mounted Led Profile Light have wide application. Size is flexible and can customized. The finish can do oxidation and sandblasting.

 

 

Specification of Surface Mounted LED Profile Light

Product Name: Recess Mounted LED Profile Light

Size: Flexible

Maximum PCB Width: 3.5mm/10mm/12mm

Ribbon inside: Suggest 9.6W/M ribbon inside

Materials: Bar material: 6063 aluminum, with oxide surface

         Cover Material: PC

         End cap material: PC

 Recess Mounted Profile Light

FAQ:

Q1. How do you ship the goods and how long does it take to arrive?
A: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline  and sea shipping also optional.

Q2. How to proceed an order for led light?


A: Firstly let us know your requirements or application.
Secondly We quote according to your requirements or our suggestions.
Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.

Q3. Is it OK to print my logo on led light product?


A: Yes. Please inform us formally before our production and confirm the design firstly based on our sample.

Q4: Do you offer guarantee for the products?


A: Yes, we offer 2-5 years warranty to our products.

Recess Mounted Led Profile Light

Recess Mounted Led Profile Light,Modern Decorative Track Light,Led Recess Mounted Profile Light,Led Profile Light

Shenzhen Jedver Smart Lighting Co., Ltd. , http://www.jederwell.com

Posted on