Description:
Optical Cable Assembly,PDLC,Single mode,GYFJH 2A1a(LSZH),7.0mm,2 Cores,2mm,Outdoor
Protected Branch Cable.
PDLC Waterproof fiber optic patch cord is standard size for Duplex LC Connectors, and the outer
housing with metal protective device. The connecting is safe and reliable. Also have the functions
of waterproof, dustpoof. This patch cords widely used in FTTA, Base station, and the outdoor
waterpoof condition.
Â
Features:
1. Standard LC Duplex connector, can be connected with normal LC Adapters
2. Light weight,waterproof, dustproof, moistureproof , Metal hard housing.
3. Â Wall seal design,easy operation, strong and durable.
Â
Application:
Used in bad outdoor condition
Used in connecting communication equipment
Used in FTTA




Â
Specifications:
 Â
Connector type | PDLC/UPC, LC/UPC |
Insertion Loss | ≤0.3db |
Return Loss | ≥55db |
Fiber Mode | Single mode(G652D,G657A) |
Cable OD | 7.0mm |
Operating Wavelength | 1310nm,1550nm |
Fiber Length | 1m, 2m….. Other length optional |
Operating Temperature | -20ºC- +75ºC |
Storage Temperature | -40ºC- +75ºC |
Ordering information:
Â
Type | Fiber Core | Cable Type | Cable OD | Cable Material | Cable Color |
Connector (A End -B End) |
Patchcord Length |
PT=Patchcord PY=Pigtail |
S1=G652D S2= G657A1 M1=50/125 M2=62.5/125 M3=OM3 M4=OM4 S7=G657A1 S8=G657B3 XX=other |
01=simplex 02=Duplex 03=Armoured 04=Distribution 05=Ribbon 06=breakout 07=drop cable XX=other |
L=0.9mm 2=2.0mm 3=3.0mm XX=other  |
1=PVC 2=LSZH Â |
01=Blue  02=Orange 03=Green  04=Brown 05=Slate  06=White 07=Red  08=Black 09=Yellow  10=Violet 11=Rose  12=Aqua 13=12Color  XX=other |
SU=SC/UPC   SA=SC/APCFU=FC/UPC    FA=FC/APC LU=LC/UPC    LA=LC/APC ST=ST/UPC  MPO=MPO/PC  MPA=MPO/APC 00=NONE XX=other  |
0.5M=0.5M 10M=10M XXX=other  |

-------------------------------------------------------FAQ---------------------------------------------------------
Q1. Can I have a sample order for this product? What' MOQ of it?
A:Â Yes welcome send sample order for test. MOQ is 1 piece.Â
Â
Q2. What about the lead time?
A:Sample needs 3-5 days, mass production time needs 1-2 weeks.Â
Â
Q3: What' s the payment term
A: We usually use TT(Telegram Transfer) in advance, Western Union. Other payment method
is negotiable.
Â
Q4. How do you ship the goods and how long does it take to arrive?
A: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping
also optional.
Â
Q5: What' s the freight of it?
A: It depends on the order quantity. We have some reliable ship forwarders. We will offer cost
effective method for you.
Â
Q6: Do you offer guarantee for the products?
A: Yes, we offer 1-2 years warranty according to different products.
Â
Q7: What action will you take if there are some product problems?
A: If there are defective ones in the batch of products, we will offer spare ones for.

Â
Description:
Optical Cable Assembly,PDLC,Single mode,GYFJH 2A1a(LSZH),7.0mm,2 Cores,2mm,Outdoor
Protected Branch Cable.
PDLC Waterproof fiber optic patch cord is standard size for Duplex LC Connectors, and the outer
housing with metal protective device. The connecting is safe and reliable. Also have the functions
of waterproof, dustpoof. This patch cords widely used in FTTA, Base station, and the outdoor
waterpoof condition.
Â
Features:
1. Standard LC Duplex connector, can be connected with normal LC Adapters
2. Light weight,waterproof, dustproof, moistureproof , Metal hard housing.
3. Â Wall seal design,easy operation, strong and durable.
Â
Application:
Used in bad outdoor condition
Used in connecting communication equipment
Used in FTTA




Â
Specifications:
 Â
Connector type | PDLC/UPC, LC/UPC |
Insertion Loss | ≤0.3db |
Return Loss | ≥55db |
Fiber Mode | Single mode(G652D,G657A) |
Cable OD | 7.0mm |
Operating Wavelength | 1310nm,1550nm |
Fiber Length | 1m, 2m….. Other length optional |
Operating Temperature | -20ºC- +75ºC |
Storage Temperature | -40ºC- +75ºC |
Ordering information:
Â
Type | Fiber Core | Cable Type | Cable OD | Cable Material | Cable Color |
Connector (A End -B End) |
Patchcord Length |
PT=Patchcord PY=Pigtail |
S1=G652D S2= G657A1 M1=50/125 M2=62.5/125 M3=OM3 M4=OM4 S7=G657A1 S8=G657B3 XX=other |
01=simplex 02=Duplex 03=Armoured 04=Distribution 05=Ribbon 06=breakout 07=drop cable XX=other |
L=0.9mm 2=2.0mm 3=3.0mm XX=other  |
1=PVC 2=LSZH Â |
01=Blue  02=Orange 03=Green  04=Brown 05=Slate  06=White 07=Red  08=Black 09=Yellow  10=Violet 11=Rose  12=Aqua 13=12Color  XX=other |
SU=SC/UPC   SA=SC/APCFU=FC/UPC    FA=FC/APC LU=LC/UPC    LA=LC/APC ST=ST/UPC  MPO=MPO/PC  MPA=MPO/APC 00=NONE XX=other  |
0.5M=0.5M 10M=10M XXX=other  |

-------------------------------------------------------FAQ---------------------------------------------------------
Q1. Can I have a sample order for this product? What' MOQ of it?
A:Â Yes welcome send sample order for test. MOQ is 1 piece.Â
Â
Q2. What about the lead time?
A:Sample needs 3-5 days, mass production time needs 1-2 weeks.Â
Â
Q3: What' s the payment term
A: We usually use TT(Telegram Transfer) in advance, Western Union. Other payment method
is negotiable.
Â
Q4. How do you ship the goods and how long does it take to arrive?
A: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping
also optional.
Â
Q5: What' s the freight of it?
A: It depends on the order quantity. We have some reliable ship forwarders. We will offer cost
effective method for you.
Â
Q6: Do you offer guarantee for the products?
A: Yes, we offer 1-2 years warranty according to different products.
Â
Q7: What action will you take if there are some product problems?
A: If there are defective ones in the batch of products, we will offer spare ones for.

Â
2.0mm (0.079") Pitch Female Headers
Overview
2.00 mm pitch female sockets/headers are low-profile connectors designed for signal and low power PC board connections when space is at a premium. Options include through-hole, surface mount and can be customized for mixed technology, press-fit and pass-through terminations. The pins and blades are available in various sizes, counts, amperages, and plating.
The 2.0mm pitch female headers are commonly found in PC`s and are also made to work in Arduino boards, Arduino Pro and Arduino Mega with either single or double-row female headers, facilitating connections for programming and incorporation into other circuits. They have the perfect height for clearing the USB-B connector and great for stacking multiple shields.
Female header always called as [Header connector", Antenk provide widely range of header connector, from 2.54mm (.100″ inch) pitch to 1.0mm (.039″ inch) pitch. The number of pins (contacts) is from 2 to 40 pins per orw. There are three type: Straight (Dip Vertical), Right angle, SMT (surface mount).
If you can not find the items you interest from above items, welcome to contact us, and you will always get fully responsive from us.
Applications of 2.0mm Pitch Female Headers
Electronics:
LED applications
Arduino boards
Solar applications
Weighing systems
Appliances:
Air conditioner
Refrigerator
Microwave oven
Washing machine
Water heater
Shower toilet
Washer/Dryer
Stove
Automotive, Heavy Duty Military and Marine
For densely packed equipment requiring weight reduction and downsizing and for tough and harsh conditions.
Vehicle infotainment
Computer peripherals
Battery Connections
Battery connections rely on the ability of the current to pass reliable and solid current. This prevents overheating in the circuit and voltage drop.
Rechargeable battery packs
Battery balancers
Battery eliminator circuits
Medical Diagnostic and Monitoring equipment
Heart monitors
Communications
TelecomsDatacoms
Mount Type: Through-hole vs Surface Mount
At one side of this female header is a series of pins which can either be mounted and soldered directly onto the surface of the PCB (SMT) or placed into drilled holes on the PCB (THM).
Through-Hole (Poke-In)
Best used for high-reliability products that require stronger connections between layers.
Aerospace and military products are most likely to require this type of mounting as these products experience extreme accelerations, collisions, or high temperatures.
Useful in test and prototyping applications that sometimes require manual adjustments and replacements.
2.0mm vertical single row female header, 2.0mm vertical dual row female header, 2.0mm right-angle single row female header and 2.0mm right-angle dual row female header are some examples of Antenk products with through-hole mount type.
Surface-Mount
The most common electronic hardware requirements are SMT.
Essential in PCB design and manufacturing, having improved the quality and performance of PCBs overall.
Cost of processing and handling is reduced.
SMT components can be mounted on both side of the board.
Ability to fit a high number of small components on a PCB has allowed for much denser, higher performing, and smaller PCBs.
2.0mm Right-angle Dual Row female header, 2.0mm SMT Single row female header and 2.0mm SMT Dual row female header are Antenk`s SMT female headers.
Soldering Temperature for 2.0mm Pitch Female Headers
Soldering SMT female connectors can be done at a maximum peak temperature of 260°C for maximum 60 seconds.
Orientation/Pin-Type: Vertical (Straight) and Right-Angle
2.0mm pitch female headers may be further classified into pin orientation as well, such as vertical or straight male header or right-angle female header.
Vertical or Straight Female Header Orientation
One side of the series of pins is connected to PCB board in which the pins can be at a right-angle to the PCB surface (usually called "straight" or [vertical") or.
Right-Angle Female Header Orientation
Parallel to the board's surface (referred to as "right-angle" pins).
Each of these pin-types have different applications that fit with their specific configuration.
PCB Connector Stacking
For 2.0mm pitch female headers, the orientation is either offered as vertical or right-angle, which are options. Elevated sockets/female headers can be available upon request.
Profile Above PCB
This type of configuration is the most common way of connecting board-to-board by a connector. First, the stacking height is calculated from one board to another and measured from the printed circuit board face to its highest insulator point above the PCB.
Elevated Sockets/Female Headers
Elevated Sockets aka Stacked sockets/receptacles or Mezzanine are simply stacked female headers providing an exact distance requirement between PCBs that optimizes electrical reliability and performance between PCB boards.
Choosing this type of stacking configuration promotes the following benefits:
Connector Isolation - the contacts are shrouded preventing cable connection mishaps and good guidance for the mating header connectors.
For off-the-shelf wireless PCB module, stacking height is optimized with elevated sockets.
Offers superior strength and rigidity.
Polarisation prevents users from inverted insertion.
Single, Dual or Multiple Number of Rows
For a 2.0mm straight or vertical female header, the standard number of rows that Antenk offers ranges from 1 to 2 rows. However, customization can be available if 3, 4 or n number of rows is needed by the customer. Also, the number of contacts for the single row is about 2-40 pins while for dual row, the number contacts may vary from 2-80 pins.
Pin Material
The pins of the connector attached to the board have been designed with copper alloy. With customer`s demand the pins can be made gold plated.
Custom 2.0mm Pitch Female Headers
Customizable 2.0 mm pitch female headers are also available, making your manufacturing process way faster as the pins are already inserted in the headers, insulator height is made at the right size and the accurate pin length you require is followed.
Parts are made using semi-automated manufacturing processes that ensure both precision and delicacy in handling the headers before packaging on tape and reel.
Tape and Reel Packaging for SMT Components
Antenk's SMT headers are offered with customizable mating pin lengths, in which each series has multiple number of of circuits, summing up to a thousand individual part number combinations per connector series.
The tape and reel carrier strip ensures that the headers are packaged within accurately sized cavities for its height, width and depth, securing the headers from the environment and maintaining consistent position during transportation.
Antenk also offer a range of custom Tape and reel carrier strip packaging cavities.
2 Pin Header,2.0Mm Female Pin Header,2.0Mm Pcb Connector,2.0 Pcb Header,0.079" Pitch Female Headers,2.0mm Female Pin Header SMT, 2.0mm Female Pin Header THT
ShenZhen Antenk Electronics Co,Ltd , https://www.antenkcon.com