The LED factory held a temporary shareholders meeting on the 14th. For the company's operating performance, the chairman of the board of directors, Jane Feng, said that the LED industry prospects continue to be optimistic. In the fourth quarter of this year, the demand for TV backlights will be slowed down, and the revenue performance may be relatively low. However, under the loose monetary policy of the United States, Thanksgiving and Christmas buying have increased, TV sales are promising, and LEDTV backlights will be in short supply in February and March next year.
At the beginning of this year, the original LED backlight TV penetration rate was estimated to be 30%. However, due to the sudden slowdown of customer pull, the LED backlight TV penetration rate was revised to 20-25%, and it is expected to see 50% next year.
Jian Fengren pointed out that there have been signs of market recovery recently, mainly due to the mainland’s eleven long holidays, TV sales are better than market expectations, to 7 million units, to successfully digest excessive inventory, and to implement monetary quantitative easing in the United States. Next, it also drove Thanksgiving and Christmas to buy gas, TV sales performance is prosperous.
He is optimistic that LEDTV backlights may be in short supply in February and March next year, and the first quarter of next year will be the bottom, and will gradually increase.
A cable is a component that connects one or more wires that can be insulated or used to transfer electrical energy or signals. Used as a primary overhead conductor for primary and secondary distribution. Designed for use with high strength aluminum alloys to achieve high strength to weight ratios; provides good droop characteristics. AAAC, ACSR is part of a series of overhead conductors, transmission conductors and distribution conductors. These cables are officially referred to as all-aluminum conductors (AAAC) and aluminum conductor bars (ACSR). These overhead aluminum conductors are used as power transmission and distribution lines. Depending on the application, all aluminum conductors are made of one or more strands of aluminum wire.
The following are the picture and parameters of our product, for more details about the cable and fitting, please contact us.
MAIN DIMENSIONS AND STANDARD PARTICULARS | ||||||
Code Number | Stranding&wire diameter | Approx Overall diameter | Norminal Area | Approx weight | Breaking Load | DC Resistance at 20 |
mm | mm | mm2 | kg/km | KN | Ohm/km | |
16 | 7/1.83 | 5.49 | 18.4 | 50.4 | 5.43 | 1.7896 |
25 | 7/2.29 | 6.86 | 28.8 | 78.7 | 8.49 | 1.1453 |
40 | 7/2.89 | 8.68 | 46 | 125.9 | 13.58 | 0.7158 |
63 | 7/3.63 | 10.9 | 72.5 | 198.3 | 21.39 | 0.4545 |
100 | 19/2.78 | 13.9 | 115 | 316.3 | 33.95 | 0.2877 |
125 | 19/3.10 | 15.5 | 144 | 395.4 | 42.44 | 0.2302 |
160 | 19/3.51 | 17.6 | 184 | 506.1 | 54.32 | 0.1798 |
200 | 19/3.93 | 19.6 | 230 | 632.7 | 67.91 | 0.1439 |
250 | 19/4.39 | 22 | 288 | 790.8 | 84.88 | 0.1151 |
315 | 37/3.53 | 24.7 | 363 | 998.9 | 106.95 | 0.0916 |
400 | 37/3.98 | 27.9 | 460 | 1268.4 | 135.81 | 0.0712 |
450 | 37/4.22 | 29.6 | 518 | 1426.9 | 152.79 | 0.0641 |
500 | 37/4.45 | 31.2 | 575 | 1585.5 | 169.76 | 0.0577 |
560 | 61/3.67 | 33 | 645 | 1778.4 | 190.14 | 0.0516 |
630 | 61/3.89 | 35 | 725 | 2000.7 | 213.9 | 0.0458 |
710 | 61/4.13 | 37.2 | 817 | 2254.8 | 241.07 | 0.0407 |
800 | 61/4.38 | 39.5 | 921 | 2540.6 | 271.62 | 0.0361 |
900 | 91/3.81 | 41.8 | 1036 | 2861.1 | 305.58 | 0.0321 |
1000 | 91/4.01 | 44.1 | 1151 | 3179 | 339.53 | 0.0289 |
1120 | 91/4.25 | 46.7 | 1289 | 3560.5 | 380.27 | 0.0258 |
1250 | 91/4.49 | 49.4 | 1439 | 3973.7 | 424.41 | 0.0231 |
MAIN DIMENSIONS AND STANDARD PARTICULARS | |||||||||
Code Number | Stranding&wire diameter | Approx Overall diameter | sectional Area | Approx weight | Breaking Load | DC Resistance at 20 | |||
AL(mm) | Steel(mm) | mm | Al(mm2) | Steel(mm2) | Total(mm2) | kg/km | KN | Ohm/km | |
16 | 6/1.84 | 1/1.84 | 5.53 | 16 | 2.67 | 18.7 | 64.6 | 6.08 | 1.7934 |
25 | 6/2.3 | 1/2.30 | 6.91 | 25 | 4.17 | 29.2 | 100.9 | 9.13 | 1.1478 |
100 | 6/4.61 | 1/4.61 | 13.8 | 100 | 16.7 | 117 | 403.8 | 34.33 | 0.2869 |
125 | 18/2.97 | 1/2.97 | 14.9 | 125 | 6.94 | 132 | 397.9 | 29.17 | 0.2304 |
160 | 18/3.36 | 1/3.36 | 16.8 | 160 | 8.89 | 169 | 509.3 | 36.18 | 0.18 |
250 | 22/3.80 | 7/2.11 | 21.6 | 250 | 24.6 | 275 | 880.6 | 68.72 | 0.1154 |
400 | 54/3.07 | 7/3.07 | 27.6 | 400 | 51.9 | 452 | 1510.3 | 123.04 | 0.0723 |
450 | 54/3.26 | 7/3.26 | 29.3 | 450 | 58.3 | 508 | 1699.1 | 138.42 | 0.0643 |
500 | 54/3.43 | 7/3.43 | 30.9 | 500 | 64.8 | 565 | 1887.9 | 153.8 | 0.0578 |
560 | 54/3.63 | 19/2.18 | 32.7 | 560 | 70.9 | 631 | 2103.4 | 172.59 | 0.0516 |
630 | 54/3.85 | 19/2.31 | 34.7 | 630 | 79.8 | 710 | 2366.3 | 191.77 | 0.0459 |
710 | 54/4.09 | 19/2.45 | 36.8 | 710 | 89.9 | 800 | 2666.8 | 216.12 | 0.0407 |
800 | 72/3.76 | 7/2.51 | 37.6 | 800 | 34.6 | 835 | 2480.2 | 167.41 | 0.0361 |
900 | 72/3.99 | 7/2.66 | 39.9 | 900 | 39.9 | 939 | 2790.2 | 188.33 | 0.0321 |
We warmly welcome friends both domestic and abroad to visit our company,if you have any questions, please contact with us directly.
Aluminum Electrical Wire,Aluminum Power Cable,Aluminum Wire Connectors,Aluminum Electrical Cable
FUZHOU SINGREE IMP.& EXP.CO.,LTD. , http://www.cninsulators.com