However, due to the technical limitations of the traditional LED control system, the information input can only be directly connected to the computer through the data line. If the display terminal interconnection in different regions is to be realized, the optical fiber and other lines must be additionally laid, which is fundamentally cost-effective. Unbearable. This has become a bottleneck that hinders the larger-scale application of LED displays: it is impossible to build a large-scale networked information distribution system, which cannot meet the needs of unified real-time publishing of remote information.
Integrate resources and grasp the growth opportunities of the LED industry. In the field of LED display technology, LED is a rapidly growing industry, both as a manufacturer and as a manufacturer and customer of LEDs. New demands are emerging, and many customers need An all-in-one solution undoubtedly requires the integration of collaborative resources and requires a highly skilled and experienced solution provider to jointly plan and respond comprehensively.
Of course, you must choose your partner carefully and choose partners that have proven to be trustworthy in all areas. Then, Dingke Technology with advanced solutions and rich industry experience is undoubtedly your best choice.
Dingke Technology's new generation of LED Internet control system, with the most advanced architecture and the most complete functions, can help to meet all kinds of latest requirements in the industry, including the large-scale remote networking requirements of LED displays.
In addition, Dingke Technology always insists on LED related manufacturers as the closest partner, and cooperates in all aspects of the industry chain, in order to produce strong synergy and win-win effect, and jointly expand LED display, which has a broad prospect and potential. Unlimited market.
Dingke Technology is an expert in "LED" with rich experience in the industry. After being swayed in the market, Dingke Technology constantly surpasses itself and makes continuous improvement on the traditional LED control system. Now Dingke has become Pioneer in the industry, Dingke Technology will lead the rapid development of the entire LED industry.
In order to let everyone know more about LED technology, Dingke Technology summed up the difference between the traditional LED control system and the current advanced LED Internet control system. As a result, not only do you have a thorough understanding of the LED control system, but you also see the whole The bright future of the LED industry.
The development and application of LED Internet control systems has very strict principles. In this regard, Dingke LED Internet Control System in the early planning and design, fully consider the advanced system of the entire system, easy to operate, scalability, compatibility, practicality, etc., we will adhere to the application of equipment The following design principles.
Operational reliability
The LED Internet control system requires various display terminals to operate in a long-term, continuous, and stable manner, and can adapt to various application characteristics. Dingke LED Internet control system reliability is mainly manifested in three aspects: First, the mature professional video technology and advanced network technology are perfectly combined; Second, the high-quality computer hardware equipment is a solid foundation for system stability, integrating today's advanced The one-key recovery function enables the maintenance of the system to be completed between the fingers; the third is to use the mode of the hard disk broadcast to ensure that the system will not be affected by external factors and interrupt the broadcast of the display terminal program.
Practical convenience
Dingke LED Internet Control System integrates video, sound, image, text and other information into one, which can display in real time on the remote terminal more quickly, and can set the position, size and content of each information window arbitrarily, system operation, window Switching and zooming, and switching of signal sources are simple and straightforward, fast and convenient. Thereby achieving higher quality customer service. Customer performance can be met in several ways:
- Object-oriented : The software of the system will set different operation interfaces according to different operation objects. We generally divide the operation objects into: central management control operator and operation terminal interface. In this way we will facilitate access control and simplify complex systems.
- Easy to construct: The common terminal display system installs the power interface and the Ethernet communication interface, and can be directly hung up.
- Easy to maintain : The control and management of the entire system is carried out through software, and the interface design of our software is easy to understand and easy to operate. The maintenance of hardware devices is also quite simple. We have an unlimited mouse and an infinite keyboard for each terminal, so we can debug it quickly even if there are serious problems.
- Friendly interface : Different operating objects have different operating interfaces, which can clearly operate the working range of the object, and has strict permission control.
- Simple installation : All software installations are very simple and are equipped with detailed operating manuals. Installation of hardware equipment We are equipped with detailed installation manuals, construction manuals, inspection methods, test methods, etc.
Technological advancement
With the rapid development of information technology, the application of high-tech means in information display systems is becoming more and more common. As a centralized display terminal for various signals (computer, video, network, etc.), the display system must have high-resolution display, uniform color stability, and good compatibility with various signals. Dingke LED Internet Control System guarantees the technological advancement of the system in many aspects:
- Communication technology: TCP/IP-based network management, good economics avoids duplication of investment, while ensuring long-term extension of the system. It can simultaneously manage and publish information on terminals with IP network conditions such as LAN, Internet, cross-network, cross-firewall, cross-router, ADSL, ISDN, GPRS wireless connection. The flexible application of the network allows the system to do whatever it wants. At the same time, the internal information release system for enterprise groups across regions and provinces is also very practical. For example, enterprise groups with branches in various provinces and cities, telecommunications, Netcom, mobile, China Unicom, electric power, banks and other provinces/municipal business offices, taxation, industrial and commercial provinces/municipal office business halls, etc. have a good application.
- Display resolution: Since the application system integrates different display devices, the problem of resolution of different display terminals is fully considered. This is a very important technology in terms of control technology, and this solution can be solved very well.
- Advanced maturity of the control system: The system is mature and stable and has been successfully operated in many engineering projects. Can solve real-time video, static text, dynamic graphics and many other format files.
Open scalability
The system follows the principle of open scalability. In addition to direct access to computer RGB, DVI, HDMI and other video signals, the display terminal can also access network signals, cable TV signals, and digital TV signals through the network controller. Through a dynamic integrated display of various computer graphics, text and network information, video image information, to provide customers with an interactive platform of high definition, high brightness and high intelligence.
- Business extensibility: The system fully considers the functions of service expansion in the control system, and has made sufficient considerations in considering scalability and equipment capacity selection, which facilitates smooth upgrade and expansion.
- Interface scalability: The selection of all devices takes into account the compatibility and expansion of other systems. For example, plasma PDP display screens should fully consider the ability to access digital TV signals, S-VIDEO, digital RGB signals, PDP serial signals, etc., as well as the scalability of other modules.
- Display terminal control device: Fully consider the interface of other signals, for example: RS232 signal transmission serial communication between PDP and PC, etc.
- Software scalability: The system fully considers the compatibility of multiple display media and the compatibility of file formats when designing the application system. Fully consider the expandable features of the future with other lines.
Operation maintainability
Dingke LED Internet Control System should be easy to diagnose faults and replace parts to reduce downtime. Preventive maintenance minimizes failures.
The company has professional and technical personnel and strong technical strength, which provides a strong guarantee for project implementation and after-sales service, and is equipped with a large number of spare parts to ensure that the system can be repaired in the shortest possible time. In addition, the system uses an advanced modular structure that allows easy removal of components. At the same time, because the design of the system takes into account the maintainability of the system, the design method integrated into the computer network is adopted, and the failure of any display terminal will not affect the system itself; at the same time, the system adopts the mode of hard disk broadcast to ensure the The system will not be affected by factors such as network interruption, and the broadcast effect will be affected. The display terminal can still independently play the program list stored in the multimedia player for automatic playback.
Energy saving and environmental protection
In the process of system construction, full consideration is given to the energy saving and environmental protection of system equipment. In the system design process, power management is carried out remotely through software, and the power intelligent management function is provided.
Dingke's LED Internet control system is a system with very powerful functions. It will be fully humanized and will provide the most thoughtful service for all enterprises and units. In the continuous development, Dingke Technology has established a good cooperative relationship with many enterprises. Dingke Technology has gradually become a leader in the LED industry with the continuous development of technology.
Click to download Dingke LED Internet Control System Solution.PDF
Chinese name
Monitoring Cable
usually
Covered line
A monitoring cable is a general term for various wires that transmit electrical or optical signals. The monitoring cable is usually a covered wire. The copper wire and the steel wire are mixed and twisted into a conductive core. The outer sheath is made of an insulating material. It is tensile and wear resistant. It is easy to retract and reuse. There are mainly video cables and RF wires. Shielded and unshielded, signal lines, control lines, etc., various models.
Monitoring Cable
Monitoring Cable,Computer Monitor Cable,Computer Monitor Cable Adapter,Extension Monitor Cable
Jiangsu QiSheng Cable Co., Ltd. , http://www.shuaihe-cable.com