16W Emergency Lighting Power Backup

Voltage: 85-265
With Light Source: With Light Source
Beam Angle: 60°
Certification: CE, UL, ISO9001, CCC, VDE, SAA
Applicable Places: Balcony
Folded: Unfolded
Product Material: High Strength RoHS Plastic
Transport Package: Standard Packing
Specification: Inverter: 172X38X30mm
Voltage: 85-265
With Light Source: With Light Source
Beam Angle: 60°
Certification: CE, UL, ISO9001, CCC, VDE, SAA
Applicable Places: Balcony
Folded: Unfolded
Product Material: High Strength RoHS Plastic
Transport Package: Standard Packing
Specification: Inverter: 172X38X30mm

16W emergency module/emergency module/emergency lighting power pack 

1.Description 

Emergency Module/Emergency conversion kit/Emergency Kit/Emergency Inverter is designed for 16W LED tube 

2.Technical Specification:

 

1. Input Voltage (Dual):  AC100V-240V, 50-60Hz
2. Normal function Indicating LED: Equipped
3. Emergency Function Testing Device: Equipped
4. Emergency Time :1 hrs
5. Battery Protection Device: Equipped
6. Operating Temp:0 ~ 55 °C
7. BatteryHigh Temp : 12V 2.2Ah Li-ion battery 
8. Start-up Charging Time: 24 hours
9. Power consumption :<5W
10. Trickle charge    :250mA
11. Normal discharge current      :  1.5A
12. Lumen factor               : 100%
 

 

Note:Test switch,LED charging indication is available,stainless steel case &backup board for option 

3.Wiring Diagram:
16W Emergency Lighting Power Backup
4.Inverter :
16W Emergency Lighting Power Backup16W Emergency Lighting Power Backup

16W emergency module/emergency module/emergency lighting power pack 

1.Description 

Emergency Module/Emergency conversion kit/Emergency Kit/Emergency Inverter is designed for 16W LED tube 

2.Technical Specification:

 

1. Input Voltage (Dual):  AC100V-240V, 50-60Hz
2. Normal function Indicating LED: Equipped
3. Emergency Function Testing Device: Equipped
4. Emergency Time :1 hrs
5. Battery Protection Device: Equipped
6. Operating Temp:0 ~ 55 °C
7. BatteryHigh Temp : 12V 2.2Ah Li-ion battery 
8. Start-up Charging Time: 24 hours
9. Power consumption :<5W
10. Trickle charge    :250mA
11. Normal discharge current      :  1.5A
12. Lumen factor               : 100%
 

 

Note:Test switch,LED charging indication is available,stainless steel case &backup board for option 

3.Wiring Diagram:
16W Emergency Lighting Power Backup
4.Inverter :
16W Emergency Lighting Power Backup16W Emergency Lighting Power Backup