18-35W Single Output LED Switching Power Supply, Power LED

Model NO.: WSP-LPC-18/35
Modulation System: PWM
In-Out: Lifting Pressure Type
Power Supply Voltage: 1.5-36V
Pack Sealing Size: SC-70
Brand: OEM
Waterproof: IP67
Trademark: OEM
Specification: CE, CB
Origin: Shenzhen, Guangdong, China
HS Code: 8504401400
Model NO.: WSP-LPC-18/35
Modulation System: PWM
In-Out: Lifting Pressure Type
Power Supply Voltage: 1.5-36V
Pack Sealing Size: SC-70
Brand: OEM
Waterproof: IP67
Trademark: OEM
Specification: CE, CB
Origin: Shenzhen, Guangdong, China
HS Code: 8504401400
LPC Series: 18-35W  Single output LED switching power supply,power LED
*LPLC-18: Only 90~132VAC input
*LPHC-18 :Only 180~264VAC input
*LPC-20/35/60: 90~264VAC input
*All sealing glue,internal accord with IP67 rating
*Withstand 300VAC surge input for 5seconds (only LPC-20/35)
*Class 2 isolation, no F.G
*Natural cooling
*Protection function: short circuit,over current,over voltage,over temperature(LPC-20/35 outside)
*Constant current design (constant current mode)
*Class 2 power supply, by LPS(limited power source)test
*100%full load ageing test
*Low cost,high reliability
*Applicable to the adornment of the LED as light source and building lighting, stage lighting and theatical lighting, LED electronic display screen.
*2 years warranty
Series No. Model No. Specification
AC input range AC inrush Current(Max.) Over voltage protection Withstand Voltage Working Temperature EMC standards Connector
input/output
Output Voltage tolerance Ripple&noise Efficiency Size(mm)
LPLC-18
(constant current mode)
LPLC-18-350 90~132VAC Cold start,
40A/115VAC
105%~135% Rated output voltage I/P-O/P:3KVAC -30ºC~+70ºC FCC part15 classA(LPLC-18),EN55022 classA,EN61000-3-2 classA, EN61000-4-2,3,4,5,6,8,11 UL,18AGWx2C(30cm) 6~48V,350mA ±8% 300mV 82.0% 140x32x22
LPLC-18-700 6~25V, 700mA ±8% 250mV 80.0%
LPHC-18
(constant current mode)
LPHC-18-350 180~264VAC Cold start,
50A/230VAC
105%~135% Rated output voltage I/P-O/P:3KVAC -30ºC~+70ºC FCC part15 classA(LPLC-18),EN55022 classA,EN61000-3-2 classA, EN61000-4-2,3,4,5,6,8,11 UL,18AGWx2C(30cm) 6~48V,350mA ±8% 300mV 82.0% 140x32x22
LPHC-18-700 6~25V, 700mA ±8% 250mV 80.0%
LPC-20
(constant current mode)
LPC-20-350 90~264VAC Cold start,
70A/230VAC
105%~135% Rated output voltage I/P-O/P:3KVAC -30ºC~+70ºC EN55022 class B,EN61000-3-2Class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11 UL,18AGWx2C(60cm) 9~48V,350mA ±5% 200mV 83.0% 118x35x26
LPC-20-700 9~30V, 700mA ±5% 200mV 83.0%
LPC-35
(constant current mode)
LPC-35-700 90~264VAC Cold start,
55A/230VAC
105%~135% Rated output voltage I/P-O/P:3KVAC -30ºC~+70ºC EN55022 class B,EN61000-3-2Class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11 Input: UL,18AGWx2C(60cm);Output:UL,16AGWx2C(60cm) 9~48V,700mA ±5% 200mV 85.0% 148x40x30
LPC-35-1050 9~30V, 1050mA ±5% 200mV 85.0%
LPC-35-1400 9~24V,1400mA ±5% 200mV 85.0%
LPC-60
(constant current mode)
LPC-60-1050 90~264VAC Cold start,
60A/230VAC
105%~135% Rated output voltage I/P-O/P:3KVAC -30ºC~+70ºC EN55022 class B,EN61000-3-2Class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11 Input: UL,18AGWx2C(60cm);Output:UL,16AGWx2C(60cm) 9~48V,1050mA ±5% 200mV 87.0% 162.5x42.5x32
LPC-60-1400 9~42V, 1400mA ±5% 200mV 85.0%
LPC-60-1750 9~34V,1750mA ±5% 200mV 87.0%
LPC Series: 18-35W  Single output LED switching power supply,power LED
*LPLC-18: Only 90~132VAC input
*LPHC-18 :Only 180~264VAC input
*LPC-20/35/60: 90~264VAC input
*All sealing glue,internal accord with IP67 rating
*Withstand 300VAC surge input for 5seconds (only LPC-20/35)
*Class 2 isolation, no F.G
*Natural cooling
*Protection function: short circuit,over current,over voltage,over temperature(LPC-20/35 outside)
*Constant current design (constant current mode)
*Class 2 power supply, by LPS(limited power source)test
*100%full load ageing test
*Low cost,high reliability
*Applicable to the adornment of the LED as light source and building lighting, stage lighting and theatical lighting, LED electronic display screen.
*2 years warranty
Series No. Model No. Specification
AC input range AC inrush Current(Max.) Over voltage protection Withstand Voltage Working Temperature EMC standards Connector
input/output
Output Voltage tolerance Ripple&noise Efficiency Size(mm)
LPLC-18
(constant current mode)
LPLC-18-350 90~132VAC Cold start,
40A/115VAC
105%~135% Rated output voltage I/P-O/P:3KVAC -30ºC~+70ºC FCC part15 classA(LPLC-18),EN55022 classA,EN61000-3-2 classA, EN61000-4-2,3,4,5,6,8,11 UL,18AGWx2C(30cm) 6~48V,350mA ±8% 300mV 82.0% 140x32x22
LPLC-18-700 6~25V, 700mA ±8% 250mV 80.0%
LPHC-18
(constant current mode)
LPHC-18-350 180~264VAC Cold start,
50A/230VAC
105%~135% Rated output voltage I/P-O/P:3KVAC -30ºC~+70ºC FCC part15 classA(LPLC-18),EN55022 classA,EN61000-3-2 classA, EN61000-4-2,3,4,5,6,8,11 UL,18AGWx2C(30cm) 6~48V,350mA ±8% 300mV 82.0% 140x32x22
LPHC-18-700 6~25V, 700mA ±8% 250mV 80.0%
LPC-20
(constant current mode)
LPC-20-350 90~264VAC Cold start,
70A/230VAC
105%~135% Rated output voltage I/P-O/P:3KVAC -30ºC~+70ºC EN55022 class B,EN61000-3-2Class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11 UL,18AGWx2C(60cm) 9~48V,350mA ±5% 200mV 83.0% 118x35x26
LPC-20-700 9~30V, 700mA ±5% 200mV 83.0%
LPC-35
(constant current mode)
LPC-35-700 90~264VAC Cold start,
55A/230VAC
105%~135% Rated output voltage I/P-O/P:3KVAC -30ºC~+70ºC EN55022 class B,EN61000-3-2Class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11 Input: UL,18AGWx2C(60cm);Output:UL,16AGWx2C(60cm) 9~48V,700mA ±5% 200mV 85.0% 148x40x30
LPC-35-1050 9~30V, 1050mA ±5% 200mV 85.0%
LPC-35-1400 9~24V,1400mA ±5% 200mV 85.0%
LPC-60
(constant current mode)
LPC-60-1050 90~264VAC Cold start,
60A/230VAC
105%~135% Rated output voltage I/P-O/P:3KVAC -30ºC~+70ºC EN55022 class B,EN61000-3-2Class C,EN61000-3-3,EN61000-4-2,3,4,5,6,8,11 Input: UL,18AGWx2C(60cm);Output:UL,16AGWx2C(60cm) 9~48V,1050mA ±5% 200mV 87.0% 162.5x42.5x32
LPC-60-1400 9~42V, 1400mA ±5% 200mV 85.0%
LPC-60-1750 9~34V,1750mA ±5% 200mV 87.0%

Evacuated Tubular Solar Water Heater

Vacuum Tube Solar Collector,Heat Pipe Solar Collector,Evacuated Tube Solar Collectors

Sunflower Renewable Energy Co., Ltd. , http://www.newestsolar.com

Posted on