2017 Module Design 5 Years Warranty LED Street Light

Model NO.: NJZ-SLA
Application: Highway, Square, Garden
IP Rating: IP67
Certification: CE, RoHS, UL, FCC, CQC,Dlc
Voltage: 100V~277V
Power Factor: > 0.95
Driver Current: 860mA
Surge Protection: 10kv
Luminous Efficiency: 110lm/W
CRI: Ra>=70
Housing Material: Die-Casting Aluminum Oxide
Lens Material: PC
CCT: 4000k/5700k
Light Distribution: Type II /Type V
Power Frequency: 50/60Hz
Trademark: NJZ
Transport Package: Carton
Specification: Warranty: 5 years
Origin: Nanjing, China
HS Code: 9405409000
Model NO.: NJZ-SLA
Application: Highway, Square, Garden
IP Rating: IP67
Certification: CE, RoHS, UL, FCC, CQC,Dlc
Voltage: 100V~277V
Power Factor: > 0.95
Driver Current: 860mA
Surge Protection: 10kv
Luminous Efficiency: 110lm/W
CRI: Ra>=70
Housing Material: Die-Casting Aluminum Oxide
Lens Material: PC
CCT: 4000k/5700k
Light Distribution: Type II /Type V
Power Frequency: 50/60Hz
Trademark: NJZ
Transport Package: Carton
Specification: Warranty: 5 years
Origin: Nanjing, China
HS Code: 9405409000
2017 Module Design 5 Years Warranty LED Street Light with CE UL DLC Certificates
2017 Module Design 5 Years Warranty LED Street Light
2017 Module Design 5 Years Warranty LED Street Light
2017 Module Design 5 Years Warranty LED Street Light
Part 1
Technical Parameter Specification NJZ-SLA-50 NJZ-SLA-100 NJZ-SLA-150 NJZ-SLA-200
Electrical Rated Power 50w 100w 150w 200w
Input Voltage                         AC100~277V
Power Frequency                           50/60Hz
Power Factor                            >0.95
Drive Current                           860mA
Surge Protection                            10KV
Optical Luminous Flux 5500Lm 11000Lm 16500Lm 22000Lm
Luminous Efficiency                          110Lm/W
Color Temperature                         4000/5700K
Module Usage 1 2 3 4
Environmental Color Rendering Index                         Ra>=70
Operating Temperature                -40ºC~+50ºC(-40°F to 122°F)
Ambient Operating Humidity                       10%~90%RH
Optimum Working Temperature                       25ºC(77°F)
Mechanical
Construction
Housing Material               Die-casting aluminum oxide
Light Distribution                   Type II /Type V
The Largest Diameter of Insatallation                        Φ60mm
Lens Material                          PC
IP Rating                          IP67
Mounting    Rocker arm installation/Rotating connecting parts
Net Weight(KG) 5.9kg 7.1kg 8.4kg 9.5kg
Dimensions(LxWxH) 406x330x193mm 491x330x193mm 576x330x193mm 661x330x193mm
Packing Total Weight(KG) 7kg 8.4kg 9.9kg 11.2kg 
Dimensions(LxWxH) 485x405x275mm  570x405x275mm 655x405x275mm 740x405x275mm
Warranty                        5-Year & L70@50,000Hrs
Certification                     CB,CE,RoHS,UL,DLC,FCC,CQC
Technical Parameter Specification NJZ-SLA-250 NJZ-SLA-300 NJZ-SLA-350 NJZ-SLA-400
Electrical Rated Power 250w 300w 350w 400w
Input Voltage                         AC100~277V
Power Frequency                           50/60Hz
Power Factor                            >0.95
Drive Current                           860mA
Surge Protection                            10KV
Optical Luminous Flux 27500Lm 33000Lm 38500Lm 44000Lm
Luminous Efficiency                          110Lm/W
Color Temperature                         4000/5700K
Module Usage 5 6 7 8
Environmental Color Rendering Index                         Ra>=70
Operating Temperature                -40ºC~+50ºC(-40°F to 122°F)
Ambient Operating Humidity                       10%~90%RH
Optimum Working Temperature                       25ºC(77°F)
Mechanical
Construction
Housing Material               Die-casting aluminum oxide
Light Distribution                   Type II /Type V
The Largest Diameter of Insatallation                        Φ60mm
Lens Material                          PC
IP Rating                          IP67
Mounting    Rocker arm installation/Rotating connecting parts
Net Weight(KG) 11kg 12.6kg 14.2kg 15.6kg
Dimensions(LxWxH) 746×330×193 mm 831×330×193 mm 916×330×193 mm 1001×330×193 mm
Packing Total Weight(KG) 13.1kg 15kg 16.6kg 18.2kg
Dimensions(LxWxH) 825×405×275mm 910×405×275mm 995×405×275mm 1080×405×275mm
Warranty                        5-Year & L70@50,000Hrs
Certification                     CB,CE,RoHS,UL,DLC,FCC,CQC
2017 Module Design 5 Years Warranty LED Street Light
2017 Module Design 5 Years Warranty LED Street Light
FAQ

1.How many LEDs does it take to replace a HPS, incandescent or flourescent light?
This can vary for each particular application with directionality and the physical area requiring illumination being the primary variables.  If you need a fluorescent, HID, or another type of luminaire to be replaced, please submit your request to us. 

2.Are your fixtures AC or DC powered?
Our SLA series offer fixtures available in the following ranges:AC ranges (100-277VAC)

3.What certification do you have for your LED Explosion proof lights?
Our NJZ-SLA series have CB,CE,RoHS,UL,DLC,FCC,CQC.

4.What is the largest diameter of installation ?
Φ60mm

5.How would I become an agent or an International Distributor?
We welcome established international distributors who have successful track records in industrial and commercial areas. Any more details,please contact us. 

6.What is your warranty?
Our standard warranty is for 60 months (5 years). View our Warranty Policy. 2017 Module Design 5 Years Warranty LED Street Light with CE UL DLC Certificates
2017 Module Design 5 Years Warranty LED Street Light
2017 Module Design 5 Years Warranty LED Street Light
2017 Module Design 5 Years Warranty LED Street Light
Part 1
Technical Parameter Specification NJZ-SLA-50 NJZ-SLA-100 NJZ-SLA-150 NJZ-SLA-200
Electrical Rated Power 50w 100w 150w 200w
Input Voltage                         AC100~277V
Power Frequency                           50/60Hz
Power Factor                            >0.95
Drive Current                           860mA
Surge Protection                            10KV
Optical Luminous Flux 5500Lm 11000Lm 16500Lm 22000Lm
Luminous Efficiency                          110Lm/W
Color Temperature                         4000/5700K
Module Usage 1 2 3 4
Environmental Color Rendering Index                         Ra>=70
Operating Temperature                -40ºC~+50ºC(-40°F to 122°F)
Ambient Operating Humidity                       10%~90%RH
Optimum Working Temperature                       25ºC(77°F)
Mechanical
Construction
Housing Material               Die-casting aluminum oxide
Light Distribution                   Type II /Type V
The Largest Diameter of Insatallation                        Φ60mm
Lens Material                          PC
IP Rating                          IP67
Mounting    Rocker arm installation/Rotating connecting parts
Net Weight(KG) 5.9kg 7.1kg 8.4kg 9.5kg
Dimensions(LxWxH) 406x330x193mm 491x330x193mm 576x330x193mm 661x330x193mm
Packing Total Weight(KG) 7kg 8.4kg 9.9kg 11.2kg 
Dimensions(LxWxH) 485x405x275mm  570x405x275mm 655x405x275mm 740x405x275mm
Warranty                        5-Year & L70@50,000Hrs
Certification                     CB,CE,RoHS,UL,DLC,FCC,CQC
Technical Parameter Specification NJZ-SLA-250 NJZ-SLA-300 NJZ-SLA-350 NJZ-SLA-400
Electrical Rated Power 250w 300w 350w 400w
Input Voltage                         AC100~277V
Power Frequency                           50/60Hz
Power Factor                            >0.95
Drive Current                           860mA
Surge Protection                            10KV
Optical Luminous Flux 27500Lm 33000Lm 38500Lm 44000Lm
Luminous Efficiency                          110Lm/W
Color Temperature                         4000/5700K
Module Usage 5 6 7 8
Environmental Color Rendering Index                         Ra>=70
Operating Temperature                -40ºC~+50ºC(-40°F to 122°F)
Ambient Operating Humidity                       10%~90%RH
Optimum Working Temperature                       25ºC(77°F)
Mechanical
Construction
Housing Material               Die-casting aluminum oxide
Light Distribution                   Type II /Type V
The Largest Diameter of Insatallation                        Φ60mm
Lens Material                          PC
IP Rating                          IP67
Mounting    Rocker arm installation/Rotating connecting parts
Net Weight(KG) 11kg 12.6kg 14.2kg 15.6kg
Dimensions(LxWxH) 746×330×193 mm 831×330×193 mm 916×330×193 mm 1001×330×193 mm
Packing Total Weight(KG) 13.1kg 15kg 16.6kg 18.2kg
Dimensions(LxWxH) 825×405×275mm 910×405×275mm 995×405×275mm 1080×405×275mm
Warranty                        5-Year & L70@50,000Hrs
Certification                     CB,CE,RoHS,UL,DLC,FCC,CQC
2017 Module Design 5 Years Warranty LED Street Light
2017 Module Design 5 Years Warranty LED Street Light
FAQ

1.How many LEDs does it take to replace a HPS, incandescent or flourescent light?
This can vary for each particular application with directionality and the physical area requiring illumination being the primary variables.  If you need a fluorescent, HID, or another type of luminaire to be replaced, please submit your request to us. 

2.Are your fixtures AC or DC powered?
Our SLA series offer fixtures available in the following ranges:AC ranges (100-277VAC)

3.What certification do you have for your LED Explosion proof lights?
Our NJZ-SLA series have CB,CE,RoHS,UL,DLC,FCC,CQC.

4.What is the largest diameter of installation ?
Φ60mm

5.How would I become an agent or an International Distributor?
We welcome established international distributors who have successful track records in industrial and commercial areas. Any more details,please contact us. 

6.What is your warranty?
Our standard warranty is for 60 months (5 years). View our Warranty Policy.

Solar Energy System

Power X (Qingdao) Energy Technology Co., Ltd. , https://www.qdpowerxsolar.com

Posted on