ACSR Bare Conductor with Certification

Model NO.: AAC,AAAC,ACSR,Galvanized steel wire,aluminum rod
Material Shape: Round Wire
Range of Application: Overhead
Certification: ISO9001, CE, UL, CCC
Brand: Jinshui Cable
Trademark: Jinshui
Transport Package: Wooden Drum or Iron-Wooden Drum as Requirements
Specification: BS IEC ASTM DIN
Origin: Zhengzhou Henan, China
HS Code: 8544492100
Model NO.: AAC,AAAC,ACSR,Galvanized steel wire,aluminum rod
Material Shape: Round Wire
Range of Application: Overhead
Certification: ISO9001, CE, UL, CCC
Brand: Jinshui Cable
Trademark: Jinshui
Transport Package: Wooden Drum or Iron-Wooden Drum as Requirements
Specification: BS IEC ASTM DIN
Origin: Zhengzhou Henan, China
HS Code: 8544492100

ACSR bare conductor with Certification

=========================================================
                            * Product Description*    
=============================
===========================
1. Applications
ACSR bare conductor with Certification has been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
2. Service Performance
ACSR bare conductor with Certification
(1).The permissible long-time operating temperature for aerial conductor is 70oC.
(2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.
(3).When connecting conductors,the conductor beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.
(4).Under installaion,the arc downing stress of all the conductors should be the same.With in the permissible distance of crossing buildings or dropping to the ground,the stress can be 10-15% higher than regular stress.
3. Product Performance
ACSR bare conductor with Certification
(1).The electrical performance of AAC and ACSR is indicated in DCΩ/km(20oC).The resistivity of the hard aluminum wire for stranded wires is not greater than 28.264 nΩ. m of international standard value.
(2).The rated tensile strength of AAC is denoted with the result of total cross-section of all aluminum conductors multiplied by min.tensile of corresponding size specified in the standard for aluminum wire.
(3).The rated tensile strengh of ACSR is denoted with sum of all aluminum conductorstensile strength and steels tensile strength.
a.The tensile strength of all aluminum conductors is denoted with the result of all cross-sections of aluminum conductors multiplied by min.tensile strength of corresponding size specified in the standard for aluminum wire.
b.The tensile strength of all steel wire is denoted with the result of all cross-sections of steel wires multiplied by the stress at 1% elongation of corresponding size specified in the standard for steel wire.
4. Material Standard
ACSR bare conductor with Certification
(1).The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).
(2).The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.
(3).Production can be arranged according to customers requirements for material standard,etc.
5.Product pictures
ACSR bare conductor with Certification
ACSR Bare Conductor with Certification
6.Part of specification
ACSR bare conductor with Certification

Code name Aluminum
Area
Stranding&
Wire Diameter
Approx
Overall
Diameter
Approx
Weight
Breaking
Load
DC
Resistance
Al Steel
AWG mm 2 No./mm No./mm mm Kg/km KN Ohm/km
Turkey 6 13.30 6/1.68 1/1.68 5.04 53.75 5303 2.157
Swan 4 21.18 6/2.12 1/2.12 6.36 85.57 8302 1335
Swanate 4 21.12 7/1.96 1/2.61 6.53 99.56 10642 1352
Sparrow 2 33.59 6/2.67 1/2.67 8.01 135.70 12653 0.854
Raven 1/0 53.52 6/3.37 1/3.37 10.10 216.20 19455 0.536
Quail 2/0 67.32 6/3.78 1/3.78 11.30 272.00 23529 0.426
Pigeon 3/0 85.14 6/4.25 1/4.25 12.80 344.00 29417 0.337
Penguin 4/0 107.20 6/4.77 1/4.77 14.30 433.40 37055 0.268
Waxwing 266800 135.00 18/3.09 1/3.09 15.50 430.50 30519 0.213
Merlin 336400 170.20 18/3.47 1/3.47 17.40 542.90 38487 0.169
Linnet 336400 170.60 26/2.89 7/2.25 18.30 689.90 62918 0.169
Hawk 477000 241.6 26/3.44 7/2.67 21.80 975.50 86011 0.120
Dove 556500 282.6 26/3.72 7/2.89 23.6 1142.00 100838 0.1030
Peacock 605000 306.2 24/4.03 7/2.69 24.2 1159.00 95861 0.0948
Drake 795000 402.5 26/4.44 7/3.45 28.1 1626.00 138669 0.0717
Rail 954000 483.8 45/3.70 7/2.47 29.6 1602.00 115626 0.0597
Other sizes can also be produced as you required.


======================================================                       *Company Description*  
====================================================== Zhengzhou Jinshui Industry & Commerce Co.Ltd is located in the national class Zhengzhou high and new technology industries zone in Zhengzhou ,Henan province. We have owned a number of exclusive essential manufacture technologies and has pass ISO 9001 Quality Management Systerm ,ISO 14001 Environmental Management Systerm ,OHSAS18001 occupational Heath Management Systerm ,ISO 10012 Measurement Management Systerm and others from China and abroad.

We have been engaged in producing electric cable and wire for nearly 20 years, and  we are also 12 year gold supplier. And we are confident that we can offer the best service and quality for you .

Our product range is as following:
 
*Bare conductors(AAC, AAAC, ACSR, Galvanized steel wire)
 *Aerial Bounded Cable (Duplex, Triplex,Quadruplex)
 * PVC insulated wire (Rated voltage to 450/750V)
 *THHN/THWN wire
 *PVC insulated Power Cable
 *XLPE insulated Power Cable 
 *Rubber sheathed Cable 
 *Control Cable
 *Welding Cable 
 *Cable Accessories

We take part in many fairs and exhibitions in China and abroad . Our aim is to be our customer's factory in Zhengzhou ,China . 
We are here to help you placing orders of cost-effective electric cable and keep tracking your products and shipment.

ACSR Bare Conductor with Certification


===========================================================

                               * Our Factory * 
==========================================================  1,Professional production lines, experienced worker, ensure the production of every thing is fine and accurate.
ACSR Bare Conductor with Certification
2,We choose excellent raw materials carefully to ensure the quality and meet the need of customers.
ACSR Bare Conductor with Certification
3,Mechanical testing of Cables is done to determine the quality and mechanical characteristics  before delivery.
ACSR Bare Conductor with Certification

4,Packaging and Shipping
We have a professional handling equipment to ensure the delivery of products.
Inner packing: wooden drum, iron wooden drum and iron drum.
Outer packing: 20',40' container 

Other packages are available according to client's request

ACSR Bare Conductor with Certification
 

====================================================== 
                                     *FAQ*      
====================================================== (1)Are  you the factory or trading company?
We are the manufacturer and 12 years gold supplier on alibaba.We are engaged in exporting cables for nearly 15 years.
 (2).When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
(3).How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
(4). What is the payment terms?
30% deposit by T/T,70% T/T after checking the copy of B/L. Or irrevocable L/C at sight .
(5).What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.


====================================================== 
                           *Contact Information* 
======================================================   Carrie Wang
Zhengzhou Jinshui Industry & Commerce Co., Ltd
     
  
Mobile:  +8613938243621
Phone:  +86-371-67836625

ACSR bare conductor with Certification

=========================================================
                            * Product Description*    
=============================
===========================
1. Applications
ACSR bare conductor with Certification has been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
2. Service Performance
ACSR bare conductor with Certification
(1).The permissible long-time operating temperature for aerial conductor is 70oC.
(2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.
(3).When connecting conductors,the conductor beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.
(4).Under installaion,the arc downing stress of all the conductors should be the same.With in the permissible distance of crossing buildings or dropping to the ground,the stress can be 10-15% higher than regular stress.
3. Product Performance
ACSR bare conductor with Certification
(1).The electrical performance of AAC and ACSR is indicated in DCΩ/km(20oC).The resistivity of the hard aluminum wire for stranded wires is not greater than 28.264 nΩ. m of international standard value.
(2).The rated tensile strength of AAC is denoted with the result of total cross-section of all aluminum conductors multiplied by min.tensile of corresponding size specified in the standard for aluminum wire.
(3).The rated tensile strengh of ACSR is denoted with sum of all aluminum conductorstensile strength and steels tensile strength.
a.The tensile strength of all aluminum conductors is denoted with the result of all cross-sections of aluminum conductors multiplied by min.tensile strength of corresponding size specified in the standard for aluminum wire.
b.The tensile strength of all steel wire is denoted with the result of all cross-sections of steel wires multiplied by the stress at 1% elongation of corresponding size specified in the standard for steel wire.
4. Material Standard
ACSR bare conductor with Certification
(1).The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).
(2).The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.
(3).Production can be arranged according to customers requirements for material standard,etc.
5.Product pictures
ACSR bare conductor with Certification
ACSR Bare Conductor with Certification
6.Part of specification
ACSR bare conductor with Certification

Code name Aluminum
Area
Stranding&
Wire Diameter
Approx
Overall
Diameter
Approx
Weight
Breaking
Load
DC
Resistance
Al Steel
AWG mm 2 No./mm No./mm mm Kg/km KN Ohm/km
Turkey 6 13.30 6/1.68 1/1.68 5.04 53.75 5303 2.157
Swan 4 21.18 6/2.12 1/2.12 6.36 85.57 8302 1335
Swanate 4 21.12 7/1.96 1/2.61 6.53 99.56 10642 1352
Sparrow 2 33.59 6/2.67 1/2.67 8.01 135.70 12653 0.854
Raven 1/0 53.52 6/3.37 1/3.37 10.10 216.20 19455 0.536
Quail 2/0 67.32 6/3.78 1/3.78 11.30 272.00 23529 0.426
Pigeon 3/0 85.14 6/4.25 1/4.25 12.80 344.00 29417 0.337
Penguin 4/0 107.20 6/4.77 1/4.77 14.30 433.40 37055 0.268
Waxwing 266800 135.00 18/3.09 1/3.09 15.50 430.50 30519 0.213
Merlin 336400 170.20 18/3.47 1/3.47 17.40 542.90 38487 0.169
Linnet 336400 170.60 26/2.89 7/2.25 18.30 689.90 62918 0.169
Hawk 477000 241.6 26/3.44 7/2.67 21.80 975.50 86011 0.120
Dove 556500 282.6 26/3.72 7/2.89 23.6 1142.00 100838 0.1030
Peacock 605000 306.2 24/4.03 7/2.69 24.2 1159.00 95861 0.0948
Drake 795000 402.5 26/4.44 7/3.45 28.1 1626.00 138669 0.0717
Rail 954000 483.8 45/3.70 7/2.47 29.6 1602.00 115626 0.0597
Other sizes can also be produced as you required.


======================================================                       *Company Description*  
====================================================== Zhengzhou Jinshui Industry & Commerce Co.Ltd is located in the national class Zhengzhou high and new technology industries zone in Zhengzhou ,Henan province. We have owned a number of exclusive essential manufacture technologies and has pass ISO 9001 Quality Management Systerm ,ISO 14001 Environmental Management Systerm ,OHSAS18001 occupational Heath Management Systerm ,ISO 10012 Measurement Management Systerm and others from China and abroad.

We have been engaged in producing electric cable and wire for nearly 20 years, and  we are also 12 year gold supplier. And we are confident that we can offer the best service and quality for you .

Our product range is as following:
 
*Bare conductors(AAC, AAAC, ACSR, Galvanized steel wire)
 *Aerial Bounded Cable (Duplex, Triplex,Quadruplex)
 * PVC insulated wire (Rated voltage to 450/750V)
 *THHN/THWN wire
 *PVC insulated Power Cable
 *XLPE insulated Power Cable 
 *Rubber sheathed Cable 
 *Control Cable
 *Welding Cable 
 *Cable Accessories

We take part in many fairs and exhibitions in China and abroad . Our aim is to be our customer's factory in Zhengzhou ,China . 
We are here to help you placing orders of cost-effective electric cable and keep tracking your products and shipment.

ACSR Bare Conductor with Certification


===========================================================

                               * Our Factory * 
==========================================================  1,Professional production lines, experienced worker, ensure the production of every thing is fine and accurate.
ACSR Bare Conductor with Certification
2,We choose excellent raw materials carefully to ensure the quality and meet the need of customers.
ACSR Bare Conductor with Certification
3,Mechanical testing of Cables is done to determine the quality and mechanical characteristics  before delivery.
ACSR Bare Conductor with Certification

4,Packaging and Shipping
We have a professional handling equipment to ensure the delivery of products.
Inner packing: wooden drum, iron wooden drum and iron drum.
Outer packing: 20',40' container 

Other packages are available according to client's request

ACSR Bare Conductor with Certification
 

====================================================== 
                                     *FAQ*      
====================================================== (1)Are  you the factory or trading company?
We are the manufacturer and 12 years gold supplier on alibaba.We are engaged in exporting cables for nearly 15 years.
 (2).When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
(3).How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
(4). What is the payment terms?
30% deposit by T/T,70% T/T after checking the copy of B/L. Or irrevocable L/C at sight .
(5).What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.


====================================================== 
                           *Contact Information* 
======================================================   Carrie Wang
Zhengzhou Jinshui Industry & Commerce Co., Ltd
     
  
Mobile:  +8613938243621
Phone:  +86-371-67836625

TVS DIODE

Transient voltage suppression diode, also known as a TVS diode, is a protective electronic component that protects electrical equipment from voltage spikes introduced by wires.


TVS diodes are placed in parallel with the circuit to be protected. When its voltage exceeds the burst breakdown level, excessive current is directly shunted. TVS diodes are clamps that suppress excessive voltages that exceed their breakdown voltage. When the overvoltage disappears, the TVS diode automatically resets and absorbs much more energy than a similarly rated crowbar circuit.

TVS,TVS DIODE,Transient voltage suppression diode

Changzhou Changyuan Electronic Co., Ltd. , https://www.changyuanelectronic.com

Posted on