Long Distance Outdoor LED Floodlight 150W/200W/300W/400W for Amusement Park Bridges

Model NO.: Rb-Fll-150wse
Certification: CE, EMC, LVD, RoHS, SAA, UL, VDE
Input Voltage: AC100-277V
LED Chips Brand: SMD3030
Item No.: Rb-Fll-150wse
LED Qty: 144PCS SMD3030/SMD5050
CCT: 3000K, 4000K, 5000K, 6000K
Luminous Flux: 18000-22500lm
Material: Aluminum+Glass
IP Rate: IP66
Power Factor: >0.95
CRI (Ra): >80
LED Power: 150W
Driver: Meanwell
Trademark: rayborn
Transport Package: 1PCS/Box
Specification: CE/RoHS/UL/SAA
Origin: China
HS Code: 9405409000
Long Distance Outdoor LED Floodlight 150W/200W/300W/400W for Amusement Park Bridges


Specifications:
LED Floodlight/Outdoor LED Flood lighting (10-1000w)
150W LED Floodlight Main Technical Parameters
Item No.: RB-FLL-150WSE
Input Voltage: AC 100-277V
Freqency Range: 50Hz~60Hz
Power Factor: >0.95
Power Efficiency: >90%
LED Power 150W
LED Chip SMD3030/SMD5050
LED QTY: 144 pcs
LED Working Voltage: DC 30~36V
System Consumption: 153W
LED Luminous Flux Warm White 15500LM
Pure White 17000LM
Cool White 18000LM
Center Illuminance 4 Meter 363 lux
4.5 Meter 286lux
6 Meter 161lux
Viewing Angle: 30/60/90/80*140°
Illuminance Uniformity: >0.6
Color Temperature Warm White 3000K~3300K
Pure White 4000K~4500K
Cool White 6000K~6500K
Color Rendering Index Ra>78
Light Distribution: LED points visible
LED Junction Temperature: ≤115ºC
Working Temperature: -40ºC~50ºC
IP Grade: IP66
Working Life-span: 50000 H
Power Line: 1.0 m three line
Connect Wire Brown L
Blue N
Yellow / Green G

Long Distance Outdoor LED Floodlight 150W/200W/300W/400W for Amusement Park Bridges
Outdoor LED Flood light Features :
LED Chip: SMD3030  SMD5050 LED Chips which is the most famous Brand in chips field, high efficiency high lumuns and long lifespan, high quality.

Power Supply: SUNPER LED flood light use Meanwell UL approved driver, IP66 and high quality, it improved lights performance. Power efficiency ≥92.

Color temperature: LED floodlight provide a range of colour temperatures from 3000, 4000,5000 and 6000 Kelvin helping to enhance a building's exterior.

Optics: Optical assembly hermetically sealed providing IP66.
Great light uniformity: LED optical systems the fixture maximize the utilization of light onto the target area, improving the uniformity of light.

Housing: Die cast aluminum housing electrostatically sprayed with a polyester powder paint finish, following anti-corrosion priming, and oven cured at 180oC.

Cable: silicon rubber cable for power input. Fasten with screw in the cable gland.
Warranty: 5 years. Do not attempt to take housing apart as this will ruin the seal and void all warranty.
Certification: DLC FCC CE RoHS approval.

Quality Control: Rigorous product testing includes high-low temperature tests, waterproof tests, shockproof tests, burn-in testing, tensile test, salt spray test and more to ensure long-term performance.

Angle Adjustable: Adjustable stainless steel mounting bracket allows you to direct light where you need it.


Full series 100W-1000W all are available :
Long Distance Outdoor LED Floodlight 150W/200W/300W/400W for Amusement Park Bridges

LED Flood light Competitive Advantage :

1.  High efficiency to meet rigorous photometric requirements.
2.  System rating 50,000 hours LM80 to reduce maintenance.
3.   LED Flood light has high-pressure cast aluminum electrical box painted electroplating both inside and outside, stainless steel or plating chromium fittings, making the installation flexible and convenient. Scuba patent technology making the optical system precision and efficiency.
4.  LED high efficiency and long life, not only provides a bright, diversity, lasting and innovative lighting environment, but also greatly reduce the purchase system and maintenance costs.
5.  Passed DesignLights Consortium (DLC) qualifications.
6.  Vented housing design isolates LED module from driver for long life and improved performance.
7.  Tempered glass lens protects LEDs and allows for easy cleaning/debris removal.
8.  Adjustable mounting bracket allows you to direct light where you need it.
9.  IP65 Rated.


Outdoor LED Flood light detailed :
Long Distance Outdoor LED Floodlight 150W/200W/300W/400W for Amusement Park Bridges


Products dimension of 100W-1000W:

Long Distance Outdoor LED Floodlight 150W/200W/300W/400W for Amusement Park Bridges



LED Flood light 12hours aging test :
Before shipping, all the LED flood lights will be over 12 hours aging tested, inspection department will test 100% products including light up test , power wattage test , high-Voltage test , waterproof test , ground connection test and so on, defective rate is controlled  less than 0.1%. Quality is ensured, you can be assured.


Outdoor LED Flood light Applications:
1. Advertising board,playground and stadium lighting.
2. Parking lot and airport lighting.
3. Highway and Railway tunnel lighting.
4. Bridge and culvert lighting.
5. Square,garden,and building lighting.
Widely used in factory,gymnasium,billboards,buildings,lawns,landscaping,offices,the site of light project and decorative lighting project etc. 
Long Distance Outdoor LED Floodlight 150W/200W/300W/400W for Amusement Park Bridges


Company Information:
 
      Rayborn Lighting Co.,Ltd is a professional manufacturer ,focus on Industrial LED lights and commerical LED lights research ,devolopment ,production,sales ,on service,was in High-end operation and service provider in High-power led .Under the country "saving "polics,we are striving to create environment protection ,energy saving ,long life lighting and earned a reputation of being a quality supplier of LED Lighting .


Payment terms: 
1. Payment: T/T, L/C at sight, Western Union ,Paypal available
2. Samples can be available within 5-7 working days; Order: 10-20Days
3. Shipping freight is quoted under your requests
4. Shipping port:Shenzhen , China
5. Discouts are offered based on order quantities


FAQ: 
1. What is the general business process?
Answer : Send Inquiry to Rayborn. → Specification Confirmation → Quotation → Sample List Confirm → Proforma Invoice → Payment Bank Slip → Sample Delivery → Sample Satisfactory → Bulk Order List → Proforma Invoice → 30% Deposit Payment in Advance → Production Ready → 70% Balance bank slip → Delivery → After Sale Service

2. What is the warranty?
Answer : 3~5 years warranty is offered depending on different types of lights. If item fails due to quality problem during warranty, we can send new replacement with freight on ours immediately if urgently. Or we prefer to send replacement with next order.

3. What is the payment term?
Answer : For sample order, we can accept T/T, Paypal, West Union, 100% in advance. For bulk order, 30% deposit in advance by T/T, 70% balance before shipping. For very big order, L/C is negotiable

4. Can I add my logo on the product label?
Answer : Yes, but order quantity is requested depending on different lights.

5. I don't know how many Led Flood Light should I use, can you advise?
Answer : Yes, we can offer our professional solution for you, IES file is available if you have the design team.

6. Do you have any MOQ limit for LED Light order?
Answer: Low MOQ, 1pc for sample checking is available .

7. How do you ship the goods and how long does it take to arrive?
Answer: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.

8. How to proceed an order for led light?
Answer : Firstly let us know your requirements or application. Secondly We quote according to your requirements or our suggestions. Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.

9. How to deal with the faulty?
Answer : Firstly, Our products are produced in strict quality control system and the defective rate < 0.2%.
Secondly, during the guarantee period, we will send new lights with new order for small quantity. For
defective batch products, we will send out new replacement to you immediately for you to solve the problem.




 

LED Accessary

LED Power Supply,LED Aluminum Profile,LED Controller

LED Track Light,SMD LED Strip,LED Downlight Co., Ltd. , http://www.cnledstrip.com

Posted on