10-200W PMDC Electric Single Phase Motor for Freezer Motor/Fluid Mixers Motor/Small Toy Motor

Model NO.: P40
Structure and Working Principle: Brush
Type: PMDC Motor
Certification: ISO9001, CCC, Ce, RoHS
Brand: OEM
Usage: Fan, Home Appliance
Construction: Permanent Magnet
Commutation: Brush
Voltage: 6-240V
Speed Rated: 1800-10000rpm
Input Power: 10-400W
Model: P4030
Length: 75mm
Torque: 154.4
Output Power: 47W
Trademark: OEM
Transport Package: Cartons
Specification: TUV, UL, VDE
Origin: China (Mainland)
HS Code: 8501109990
Model NO.: P40
Structure and Working Principle: Brush
Type: PMDC Motor
Certification: ISO9001, CCC, Ce, RoHS
Brand: OEM
Usage: Fan, Home Appliance
Construction: Permanent Magnet
Commutation: Brush
Voltage: 6-240V
Speed Rated: 1800-10000rpm
Input Power: 10-400W
Model: P4030
Length: 75mm
Torque: 154.4
Output Power: 47W
Trademark: OEM
Transport Package: Cartons
Specification: TUV, UL, VDE
Origin: China (Mainland)
HS Code: 8501109990
Our Company Website http://www.hkritscher.com

1. Stator size is optional
2. Safe, reliable, low noise, good starting, long life
3. Strong power
Rated voltage
110~120V/220~240V-50/60Hz
Typical used: Exhaust fan, air purifier, micro-oven, fan, induction cooker, refrigerator, pump, heater, hood oven, blwer, air conditioner, Heater machines, dehumidifiers
Thermal protector with one shot fuse or multi shot fuse


Fitness apparatus PMDC motor is widely usedn in home appliances as Microwave turing plate, Quartz heater, Dishwasher, Can opener, Knife sharpener, washing machine, automation product
1. Rated: 6-240VDC
2. Rated speed: 1800-10000rpm
3. Input Power: 10-400W
4. Insulation class: A B F H
 


 
Typical Market                
Products for industry and commerce uses motor            
Application                
Household appliances motor  Office supplies motor  Electric tools motor  Industrial equipment motor    
Main Technical Parameters                
Vol: 6-240V DC              
Rated Speed: 1800-10000RPM            
Rated Input Power: 10-400W            
Insulation Class: A B F H            
Typical application            
Fitness Apparatus            Massager            
Food Processor               Medical Equipment          
                 
                 
                 
                 
                  
Typical model load performance             
  Type length(mm) Rated Voltage (V) Current (A) input Power(W) Speed (RPM) Torque output Power(W) Max Eff.(%)
P4030 75 24 2.93 70 2929 154.4 47 68
P4040 85 120 1.64 196 7511 182.3 143 72.8
                 

10-200W PMDC Electric Single Phase Motor for Freezer Motor/Fluid Mixers Motor/Small Toy Motor

10-200W PMDC Electric Single Phase Motor for Freezer Motor/Fluid Mixers Motor/Small Toy Motor
10-200W PMDC Electric Single Phase Motor for Freezer Motor/Fluid Mixers Motor/Small Toy Motor




ABOUT US

Ritscher group was set up in 2006.we always focus on micro-motors for household electrical appliance and industry appliance since setting up.currently we have two professional micro-motor factories in China  which severally located in Ningbo city and Foshan city.it has an area of 25,000 square meters plants and more than 300 employees, annual output  is 3 million pcs and has 5 million pcs annual producing capacity.after several years development,we had built a great reputation in the market and got more and more customers'  trust in the world.
We  started from shaded pole motors  at beginning, up to now,our product  included of shaded pole motors,synchronous motors,stepping motors ,capacitor motors, BLDC motors, DC motors and compressors. Our product  are widely used for making refrigerators, freezers, micro-wave ovens, air warmers, air exhausters, ventilators,ovens, air filter, massage machines and many other equipments.
As a realiable quality guaranty,Ritscher has complete R&D departement,QC department,producing department,purchase department etc. has perfect producing equipment like Aluminum diecasting, Zinc diecasting, Sheet metal stamping, Plastic injection molding etc. also test/ detection device like multiplex temp measuring device, performance parameter inspection device, Phenol peptide solution pinhole tester,Anechoic room etc.
 
Endeavoring to provide the best product and service to customers,we always do the most effort to become an outstanding manufacturer of micro motors.
Ritscher is always willing to establish sincere business relationship with friends from all over the world.
Welcome contact with us!
 
Take ritscher ,enjoy modern life!



Our company FAQ for you

(1) Q: What kind motors you can provide?
A:For now,we mainly provide Kitchen Hood Motor,DC Motor,Gear Motor,Fan Motor Refrigerator Motor,Hair Dryer Motor Blender Motor Mixer Motor,
Shade Pole Motor,Capacitor Motor,BLDC Motor PMDC Motor,Synchronous Motor,Stepping Motor etc.

(2) Q: Is it possible to visit your factory
A: Sure. But please kindly keep us posted a few days in advance. We need to check our
schedule to see if we are available then.

(3) Q: Can I get some samples
A: It depends. If only a few samples for personal use or replacement, I am afraid it will
be difficult for us to provide, because all of our motors are custom made and no stock
available if there is no further needs. If just sample testing before the official order and
our MOQ, price and other terms are acceptable, we'd love to provide samples.

(4) Q: Is there a MOQ for your motors?
A: Yes. The MOQ is between 1000~10,000pcs for different models after sample approval.
But it's also okay for us to accept smaller lots like a few dozens, hundreds or thousands
For the initial 3 orders after sample approval.For samples, there is no MOQ requirement. But the less the better (like no more than 5pcs) on condition that the quantity is enough in case any changes needed after initial testing.

  Our Company Website http://www.hkritscher.com

1. Stator size is optional
2. Safe, reliable, low noise, good starting, long life
3. Strong power
Rated voltage
110~120V/220~240V-50/60Hz
Typical used: Exhaust fan, air purifier, micro-oven, fan, induction cooker, refrigerator, pump, heater, hood oven, blwer, air conditioner, Heater machines, dehumidifiers
Thermal protector with one shot fuse or multi shot fuse


Fitness apparatus PMDC motor is widely usedn in home appliances as Microwave turing plate, Quartz heater, Dishwasher, Can opener, Knife sharpener, washing machine, automation product
1. Rated: 6-240VDC
2. Rated speed: 1800-10000rpm
3. Input Power: 10-400W
4. Insulation class: A B F H
 


 
Typical Market                
Products for industry and commerce uses motor            
Application                
Household appliances motor  Office supplies motor  Electric tools motor  Industrial equipment motor    
Main Technical Parameters                
Vol: 6-240V DC              
Rated Speed: 1800-10000RPM            
Rated Input Power: 10-400W            
Insulation Class: A B F H            
Typical application            
Fitness Apparatus            Massager            
Food Processor               Medical Equipment          
                 
                 
                 
                 
                  
Typical model load performance             
  Type length(mm) Rated Voltage (V) Current (A) input Power(W) Speed (RPM) Torque output Power(W) Max Eff.(%)
P4030 75 24 2.93 70 2929 154.4 47 68
P4040 85 120 1.64 196 7511 182.3 143 72.8
                 

10-200W PMDC Electric Single Phase Motor for Freezer Motor/Fluid Mixers Motor/Small Toy Motor

10-200W PMDC Electric Single Phase Motor for Freezer Motor/Fluid Mixers Motor/Small Toy Motor
10-200W PMDC Electric Single Phase Motor for Freezer Motor/Fluid Mixers Motor/Small Toy Motor




ABOUT US

Ritscher group was set up in 2006.we always focus on micro-motors for household electrical appliance and industry appliance since setting up.currently we have two professional micro-motor factories in China  which severally located in Ningbo city and Foshan city.it has an area of 25,000 square meters plants and more than 300 employees, annual output  is 3 million pcs and has 5 million pcs annual producing capacity.after several years development,we had built a great reputation in the market and got more and more customers'  trust in the world.
We  started from shaded pole motors  at beginning, up to now,our product  included of shaded pole motors,synchronous motors,stepping motors ,capacitor motors, BLDC motors, DC motors and compressors. Our product  are widely used for making refrigerators, freezers, micro-wave ovens, air warmers, air exhausters, ventilators,ovens, air filter, massage machines and many other equipments.
As a realiable quality guaranty,Ritscher has complete R&D departement,QC department,producing department,purchase department etc. has perfect producing equipment like Aluminum diecasting, Zinc diecasting, Sheet metal stamping, Plastic injection molding etc. also test/ detection device like multiplex temp measuring device, performance parameter inspection device, Phenol peptide solution pinhole tester,Anechoic room etc.
 
Endeavoring to provide the best product and service to customers,we always do the most effort to become an outstanding manufacturer of micro motors.
Ritscher is always willing to establish sincere business relationship with friends from all over the world.
Welcome contact with us!
 
Take ritscher ,enjoy modern life!



Our company FAQ for you

(1) Q: What kind motors you can provide?
A:For now,we mainly provide Kitchen Hood Motor,DC Motor,Gear Motor,Fan Motor Refrigerator Motor,Hair Dryer Motor Blender Motor Mixer Motor,
Shade Pole Motor,Capacitor Motor,BLDC Motor PMDC Motor,Synchronous Motor,Stepping Motor etc.

(2) Q: Is it possible to visit your factory
A: Sure. But please kindly keep us posted a few days in advance. We need to check our
schedule to see if we are available then.

(3) Q: Can I get some samples
A: It depends. If only a few samples for personal use or replacement, I am afraid it will
be difficult for us to provide, because all of our motors are custom made and no stock
available if there is no further needs. If just sample testing before the official order and
our MOQ, price and other terms are acceptable, we'd love to provide samples.

(4) Q: Is there a MOQ for your motors?
A: Yes. The MOQ is between 1000~10,000pcs for different models after sample approval.
But it's also okay for us to accept smaller lots like a few dozens, hundreds or thousands
For the initial 3 orders after sample approval.For samples, there is no MOQ requirement. But the less the better (like no more than 5pcs) on condition that the quantity is enough in case any changes needed after initial testing.

 

Pre-insulated Terminal

Pre-insulated Terminal,Digital Voltmeter ,Surge Protector ,Terminal Block

Rubber Tube, Pipe & Hose Co., Ltd. , http://www.nbflexibletube.com

Posted on