XLPE Insulated Aluminium Conductor Service Drop Aerial Bundle ABC Cable

Model NO.: 3x70+55+25mm2
Material Shape: Round Wire
Range of Application: LSOH
Certification: ISO9001, RoHS, VDE
Brand: Jytop
Standard: ASTM, AS/NZS, BS, CSA, DIN, IEC...
Certificate: Ce, ISO 9001
Core Number: Duplex, Triplex, Quadruplex Cable
Trademark: JYTOP
Transport Package: Standard Export Drum
Specification: 3x95+55+25mm2
Origin: Zhengzhou, China
HS Code: 7614100000
Model NO.: 3x70+55+25mm2
Material Shape: Round Wire
Range of Application: LSOH
Certification: ISO9001, RoHS, VDE
Brand: Jytop
Standard: ASTM, AS/NZS, BS, CSA, DIN, IEC...
Certificate: Ce, ISO 9001
Core Number: Duplex, Triplex, Quadruplex Cable
Trademark: JYTOP
Transport Package: Standard Export Drum
Specification: 3x95+55+25mm2
Origin: Zhengzhou, China
HS Code: 7614100000
overhead XLPE Insulated Aluminium Conductor Service Drop Aerial Boundle ABC Cable

XLPE Insulated Aluminium Conductor Service Drop Aerial Bundle ABC Cable

Service Drop aerial boundle ABC cable
We produce the ABC Electric Cable used for overhead line(duplex, triplex, quadruplex) in IEC standard, ASTM ANSI/ICEA S-76-474   NF C 33-209 standard.

LV ABC cable(Aerial Bundle cable) with AAAC conductor
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, Duplex, Triplex, Quadruplex.
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.


TYPE ONE service drop wire ABC cable
ABC CABLE -aerial bundle cable :are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
 
Applications

To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.

Construction

Phase Conductor construction:The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.

Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:

Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded

Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded

Aluminum alloy 6201-T81, concentric-lay-stranded

Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)
XLPE Insulated Aluminium Conductor Service Drop Aerial Bundle ABC Cable

Alternatively, black linear low-density polyethylene (LLDPE) insulation with a 75°C temperature rating is available upon request. 
Standards
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

Data sheet

Code Phase Conductor Bare Neutral Messenger Weight Per Rating(Amps)
Name 1000 ft(lbs)
  Size Strand Insulation Size *Strand Breaking XLP POLY XLP POLY
  AWG thickness AWG strength
    (mls)   (lbs)
AAC
Pekingese 6 solid 45 6 7/w 563 63.5 61.7 70 70
Collie 6 7/w 45 6 7/w 563 66.8 63.1 70 70
Dachshund 4 solid 45 4 7/w 881 95.5 93.4 90 90
Spaniel 4 7/w 45 4 7/w 881 101 95.4 90 90
Doberman 2 7/w 45 2 7/w 1,350 153 145.7 120 120
Malemute 1/0 19/w 60 1/0 7/w 1,990 243 234.2 160 160
ACSR NEUTRAL-MESSENGER
Setter 6 solid 45 6 '6/1 1.19 75 73.2 70 70
Shepherd 6 7/w 45 6 '6/2 1.19 78.3 74.6 70 70
Eskimo 4 solid 45 4 '6/3 1.86 114 111.6 90 90
Terrier 4 7/w 45 4 '6/4 1.86 119 113.6 90 90
Chow 2 7/w 45 2 '6/5 2.85 182 174.7 120 120
Bull 1/0 19/w 60 1/0 '6/6 4.38 289 280.3 160 160
6201 ALLOY NEUTRAL-MESSENGER
Chihuahua 6 solid 45 6 7/w 1,110 67.6 65.8 70 70
Vizsla 6 7/w 45 6 7/w 1,110 70.9 67.2 70 70
Harrier 4 solid 45 4 7/w 1,760 102 99.9 90 90
Whippet 4 7/w 45 4 7/w 1,760 107 101.9 90 90
Schnauzer 2 7/w 45 2 7/w 2,800 163 156.2 120 120
Heeler 1/0 19/w 60 1/0 7/w 4,460 259 250.8 160 160


 Triplex Service Drop-Aluminum Conductor
Code Phase Conductor Bare Neutral Messenger Weight Per Ampacity (Amps)
Name 1000 ft(lbs)
  Size Stranding Insulation Size Stranding Breaking XLP POLY XLP POLY
  AWG thickness AWG strength
    (mls)   (lbs)
6201 ALLOY NEUTRAL-MESSENGER
Minex 6 solid 45 6 7 1,110 106.6 102.9 85 70
Hippa 6 7/w 45 6 7 1,110 113.2 105.7 85 70
Prawn 4 solid 45 4 7 1,760 158.4 154.1 115 90
Barnacles 4 7/w 45 4 7 1,760 168.3 158.2 115 90
Shrimp 2 7/w 45 2 7 2,800 253.7 239.7 150 120
Gammarus 1/0 7/w 60 1/0 7 4,460 411.7 386 205 160
Leda 1/0 19/w 60 1/0 7 4,460 402.7 386 205 160
Dungenese 2/0 7/w 60 2/0 7 5,390 506.8 476.3 235 185
Cyclops 2/0 19/w 60 2/0 7 5,390 495.3 476.3 235 185
Flustra 3/0 19/w 60 3/0 7 6,790 611.4 589.1 275 215
Lepas 4/0 19/w 60 4/0 7 8,560 757.1 730.5 315 245
6201 ALLOY REDUCED NEUTRAL-MESSENGER
Artemia 4 solid 45 6 7 1,110 141.4 137.1 115 90
Crab 4 7/w 45 6 7 1,110 151.3 141.2 115 90
Solaster 2 7/w 45 4 7 1,760 226.6 212.6 150 120
Sandcrab 1/0 7/w 60 2 7 2,800 368.8 343.1 205 160
Echinus 1/0 19/w 60 2 7 2,800 358.8 343.1 205 160
Crayfish 2/0 7/w 60 1 7 3,530 452.6 422.5 235 185
Sipho 2/0 19/w 60 1 7 3,530 441 422.5 235 185
Fulgar 3/0 19/w 60 1/0 7 4,460 543.4 521.1 275 215
Arca 4/0 19/w 60 2/0 7 5,390 671.2 644.6 315 245
AAC NEUTRAL-MESSENGER
Haiotis 6 solid 45 6 7 563 102.5 98.8 85 70
Patella 6 7/w 45 6 7 563 109.1 101.6 85 70
Fusus 4 solid 45 4 7 881 151.9 147.6 115 90
Oyster 4 7/w 45 4 7 881 161.8 151.7 115 90
Clam 2 7/w 45 2 7 1,350 243.2 229.2 150 120
Murex 1/0 7/w 60 1/0 7 1,990 395.1 369.4 205 160
Purpura 1/0 19/w 60 1/0 7 1,990 386.1 369.4 205 160
Nassa 2/0 7/w 60 2/0 7 2,510 485.8 455.3 235 185
Melita 3/0 19/w 60 3/0 19 3,310 585.2 562.9 275 215
Portunus 4/0 19/w 60 4/0 19 4,020 723.9 697.3 315 245
Nannynose 336.4 19/w 80 336 19 6,146 1160 1118 420 325
WITH FULL SIZE ACSR MESSENGER
Paludina 6 solid 45 6 '6/1 1,190 114 113 85 70
Voluta 6 7/w 45 6 '6/1 1,190 120 113 85 70
Whelk 4 solid 45 4 '6/1 1,860 169 165 115 90
Periwinkle 4 7/w 45 4 '6/1 1,860 176 172 115 90
Conch 2 7/w 45 2 '6/1 2,850 267 261 150 120
Neritina 1/0 7/w 60 1/0 '6/1 4,380 530 419 205 160
Cenia 1/0 19/w 60 1/0 '6/1 4,380 426 416 205 160
Runcina 2/0 7/w 60 2/0 '6/1 5,310 530 519 235 185
Triton 2/0 19/w 60 2/0 '6/1 5,310 526 514 235 185
Cherrystone 3/0 7/w 60 3/0 '6/1 6,620 656 643 250 200
Mursia 3/0 19/w 60 3/0 '6/1 6,620 650 638 250 200
Razor 4/0 7/w 60 4/0 '6/1 8,350 814 799 315 245
Zuzara 4/0 19/w 60 4/0 '6/1 8,350 805 792 315 245
Limpet 336.4 19/w 80 336 '6/1 8,680 1209 1167 420 325
WITH ACSR REDUCED SIZE MESSENGER
Scallop 4 Solid 45 6 '6/1 1,190 148 144 115 90
Strombus 4 7/w 45 6 '6/1 1,190 158 148 115 90
Cockle 2 7/ w 45 4 '6/1 1,860 233 227 150 120
Janthina 1/0 7/ w 60 2 '6/1 2,850 376 365 205 160
Ranella 1/0 19/ w 60 2 '6/1 2,850 372 362 205 160

Quadruplex Service Drop-Aluminum Conductor
Code Phase Conductor Bare Neutral Messenger Weight Per Rating(Amps)
Name 1000 ft(lbs)
  Size Strand Insulation Size Strand Breaking XLP POLY XLP POLY
  AWG thickness AWG strength
    (mls)   (lbs)
AAC NEUTRAL-MESSNGER
Clydesdale 4 Solid 45 4 7 881 208 201.8 100 80
Pinto 4 7/w 45 4 7 881 223 207.9 100 80
Mustang 2 7/w 45 2 7 1,350 333 312.6 135 105
Criollo 1/0 19/w 60 1/0 7 1,990 529 504.5 180 140
Percheron 2/0 19/w 60 2/0 7 2,510 649 620.5 205 160
Hanoverian 3/0 19/w 60 3/0 19 3,310 799 765.6 235 185
Oldenburg 4/0 19/w 60 4/0 19 4,020 986 946.7 275 210
Lippizaner 336.4 19/w 80 336.4 19 6,146 1,546 1,519.20 370 280
ACSR NEUTRAL-MESSNGER
Morochuca 6 Solid 45 6 '6/1 1,190 152 147.4 75 60
Chola 6 7/w 45 6 '6/1 1,190 162 151.7 75 60
Morgan 4 Solid 45 4 '6/1 1,860 226 220 100 80
Hackney 4 7/w 45 4 '6/1 1,860 241 226.1 100 80
Palomino 2 7/w 45 2 '6/1 2,850 362 342.6 135 105
Costena 1/0 19/w 60 1/0 '6/1 4,380 575 550.6 180 140
Grullo 2/0 19/w 60 2/0 '6/1 5,310 707 678.7 205 160
Suffolk 3/0 19/w 60 3/0 '6/1 6,620 872 838.9 235 185
Appaloosa 4/0 19/w 60 4/0 '6/1 8,350 1079 1039.2 275 210
Bronco 336.4 19/w 80 336.4 '18/1 8,580 1613 1568.2 370 280
Gelding 336.4 19/w 80 4/0 '6/1 8,350 1548 1494.3 370 280
 
6201 ALLOY NEUTRAL-MESSENGER
Bay 6 Solid 45 6 7 1,110 145 140 75 60
French Coach 6 7/w 45 6 7 1,110 155 144.3 75 60
German Coach 4 Solid 45 4 7 1,760 214 208.3 100 80
Arabian 4 7/w 45 4 7 1,760 229 214.4 100 80
Belgian 2 7/w 45 2 7 2,800 344 323.1 135 105
Shetland 1/0 19/w 60 1/0 7 4,460 546 521.1 180 140
Thoroughbred 2/0 19/w 60 2/0 7 5,390 670 641.5 205 160
Trotter 3/0 19/w 60 3/0 7 6,790 825 791.8 235 185
Walking  4/0 19/w 60 4/0 7 8,560 1019 979.7 275 210

XLPE Insulated Aluminium Conductor Service Drop Aerial Bundle ABC Cable overhead XLPE Insulated Aluminium Conductor Service Drop Aerial Boundle ABC Cable

XLPE Insulated Aluminium Conductor Service Drop Aerial Bundle ABC Cable

Service Drop aerial boundle ABC cable
We produce the ABC Electric Cable used for overhead line(duplex, triplex, quadruplex) in IEC standard, ASTM ANSI/ICEA S-76-474   NF C 33-209 standard.

LV ABC cable(Aerial Bundle cable) with AAAC conductor
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, Duplex, Triplex, Quadruplex.
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.


TYPE ONE service drop wire ABC cable
ABC CABLE -aerial bundle cable :are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
 
Applications

To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.

Construction

Phase Conductor construction:The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.

Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:

Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded

Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded

Aluminum alloy 6201-T81, concentric-lay-stranded

Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)
XLPE Insulated Aluminium Conductor Service Drop Aerial Bundle ABC Cable

Alternatively, black linear low-density polyethylene (LLDPE) insulation with a 75°C temperature rating is available upon request. 
Standards
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

Data sheet

Code Phase Conductor Bare Neutral Messenger Weight Per Rating(Amps)
Name 1000 ft(lbs)
  Size Strand Insulation Size *Strand Breaking XLP POLY XLP POLY
  AWG thickness AWG strength
    (mls)   (lbs)
AAC
Pekingese 6 solid 45 6 7/w 563 63.5 61.7 70 70
Collie 6 7/w 45 6 7/w 563 66.8 63.1 70 70
Dachshund 4 solid 45 4 7/w 881 95.5 93.4 90 90
Spaniel 4 7/w 45 4 7/w 881 101 95.4 90 90
Doberman 2 7/w 45 2 7/w 1,350 153 145.7 120 120
Malemute 1/0 19/w 60 1/0 7/w 1,990 243 234.2 160 160
ACSR NEUTRAL-MESSENGER
Setter 6 solid 45 6 '6/1 1.19 75 73.2 70 70
Shepherd 6 7/w 45 6 '6/2 1.19 78.3 74.6 70 70
Eskimo 4 solid 45 4 '6/3 1.86 114 111.6 90 90
Terrier 4 7/w 45 4 '6/4 1.86 119 113.6 90 90
Chow 2 7/w 45 2 '6/5 2.85 182 174.7 120 120
Bull 1/0 19/w 60 1/0 '6/6 4.38 289 280.3 160 160
6201 ALLOY NEUTRAL-MESSENGER
Chihuahua 6 solid 45 6 7/w 1,110 67.6 65.8 70 70
Vizsla 6 7/w 45 6 7/w 1,110 70.9 67.2 70 70
Harrier 4 solid 45 4 7/w 1,760 102 99.9 90 90
Whippet 4 7/w 45 4 7/w 1,760 107 101.9 90 90
Schnauzer 2 7/w 45 2 7/w 2,800 163 156.2 120 120
Heeler 1/0 19/w 60 1/0 7/w 4,460 259 250.8 160 160


 Triplex Service Drop-Aluminum Conductor
Code Phase Conductor Bare Neutral Messenger Weight Per Ampacity (Amps)
Name 1000 ft(lbs)
  Size Stranding Insulation Size Stranding Breaking XLP POLY XLP POLY
  AWG thickness AWG strength
    (mls)   (lbs)
6201 ALLOY NEUTRAL-MESSENGER
Minex 6 solid 45 6 7 1,110 106.6 102.9 85 70
Hippa 6 7/w 45 6 7 1,110 113.2 105.7 85 70
Prawn 4 solid 45 4 7 1,760 158.4 154.1 115 90
Barnacles 4 7/w 45 4 7 1,760 168.3 158.2 115 90
Shrimp 2 7/w 45 2 7 2,800 253.7 239.7 150 120
Gammarus 1/0 7/w 60 1/0 7 4,460 411.7 386 205 160
Leda 1/0 19/w 60 1/0 7 4,460 402.7 386 205 160
Dungenese 2/0 7/w 60 2/0 7 5,390 506.8 476.3 235 185
Cyclops 2/0 19/w 60 2/0 7 5,390 495.3 476.3 235 185
Flustra 3/0 19/w 60 3/0 7 6,790 611.4 589.1 275 215
Lepas 4/0 19/w 60 4/0 7 8,560 757.1 730.5 315 245
6201 ALLOY REDUCED NEUTRAL-MESSENGER
Artemia 4 solid 45 6 7 1,110 141.4 137.1 115 90
Crab 4 7/w 45 6 7 1,110 151.3 141.2 115 90
Solaster 2 7/w 45 4 7 1,760 226.6 212.6 150 120
Sandcrab 1/0 7/w 60 2 7 2,800 368.8 343.1 205 160
Echinus 1/0 19/w 60 2 7 2,800 358.8 343.1 205 160
Crayfish 2/0 7/w 60 1 7 3,530 452.6 422.5 235 185
Sipho 2/0 19/w 60 1 7 3,530 441 422.5 235 185
Fulgar 3/0 19/w 60 1/0 7 4,460 543.4 521.1 275 215
Arca 4/0 19/w 60 2/0 7 5,390 671.2 644.6 315 245
AAC NEUTRAL-MESSENGER
Haiotis 6 solid 45 6 7 563 102.5 98.8 85 70
Patella 6 7/w 45 6 7 563 109.1 101.6 85 70
Fusus 4 solid 45 4 7 881 151.9 147.6 115 90
Oyster 4 7/w 45 4 7 881 161.8 151.7 115 90
Clam 2 7/w 45 2 7 1,350 243.2 229.2 150 120
Murex 1/0 7/w 60 1/0 7 1,990 395.1 369.4 205 160
Purpura 1/0 19/w 60 1/0 7 1,990 386.1 369.4 205 160
Nassa 2/0 7/w 60 2/0 7 2,510 485.8 455.3 235 185
Melita 3/0 19/w 60 3/0 19 3,310 585.2 562.9 275 215
Portunus 4/0 19/w 60 4/0 19 4,020 723.9 697.3 315 245
Nannynose 336.4 19/w 80 336 19 6,146 1160 1118 420 325
WITH FULL SIZE ACSR MESSENGER
Paludina 6 solid 45 6 '6/1 1,190 114 113 85 70
Voluta 6 7/w 45 6 '6/1 1,190 120 113 85 70
Whelk 4 solid 45 4 '6/1 1,860 169 165 115 90
Periwinkle 4 7/w 45 4 '6/1 1,860 176 172 115 90
Conch 2 7/w 45 2 '6/1 2,850 267 261 150 120
Neritina 1/0 7/w 60 1/0 '6/1 4,380 530 419 205 160
Cenia 1/0 19/w 60 1/0 '6/1 4,380 426 416 205 160
Runcina 2/0 7/w 60 2/0 '6/1 5,310 530 519 235 185
Triton 2/0 19/w 60 2/0 '6/1 5,310 526 514 235 185
Cherrystone 3/0 7/w 60 3/0 '6/1 6,620 656 643 250 200
Mursia 3/0 19/w 60 3/0 '6/1 6,620 650 638 250 200
Razor 4/0 7/w 60 4/0 '6/1 8,350 814 799 315 245
Zuzara 4/0 19/w 60 4/0 '6/1 8,350 805 792 315 245
Limpet 336.4 19/w 80 336 '6/1 8,680 1209 1167 420 325
WITH ACSR REDUCED SIZE MESSENGER
Scallop 4 Solid 45 6 '6/1 1,190 148 144 115 90
Strombus 4 7/w 45 6 '6/1 1,190 158 148 115 90
Cockle 2 7/ w 45 4 '6/1 1,860 233 227 150 120
Janthina 1/0 7/ w 60 2 '6/1 2,850 376 365 205 160
Ranella 1/0 19/ w 60 2 '6/1 2,850 372 362 205 160

Quadruplex Service Drop-Aluminum Conductor
Code Phase Conductor Bare Neutral Messenger Weight Per Rating(Amps)
Name 1000 ft(lbs)
  Size Strand Insulation Size Strand Breaking XLP POLY XLP POLY
  AWG thickness AWG strength
    (mls)   (lbs)
AAC NEUTRAL-MESSNGER
Clydesdale 4 Solid 45 4 7 881 208 201.8 100 80
Pinto 4 7/w 45 4 7 881 223 207.9 100 80
Mustang 2 7/w 45 2 7 1,350 333 312.6 135 105
Criollo 1/0 19/w 60 1/0 7 1,990 529 504.5 180 140
Percheron 2/0 19/w 60 2/0 7 2,510 649 620.5 205 160
Hanoverian 3/0 19/w 60 3/0 19 3,310 799 765.6 235 185
Oldenburg 4/0 19/w 60 4/0 19 4,020 986 946.7 275 210
Lippizaner 336.4 19/w 80 336.4 19 6,146 1,546 1,519.20 370 280
ACSR NEUTRAL-MESSNGER
Morochuca 6 Solid 45 6 '6/1 1,190 152 147.4 75 60
Chola 6 7/w 45 6 '6/1 1,190 162 151.7 75 60
Morgan 4 Solid 45 4 '6/1 1,860 226 220 100 80
Hackney 4 7/w 45 4 '6/1 1,860 241 226.1 100 80
Palomino 2 7/w 45 2 '6/1 2,850 362 342.6 135 105
Costena 1/0 19/w 60 1/0 '6/1 4,380 575 550.6 180 140
Grullo 2/0 19/w 60 2/0 '6/1 5,310 707 678.7 205 160
Suffolk 3/0 19/w 60 3/0 '6/1 6,620 872 838.9 235 185
Appaloosa 4/0 19/w 60 4/0 '6/1 8,350 1079 1039.2 275 210
Bronco 336.4 19/w 80 336.4 '18/1 8,580 1613 1568.2 370 280
Gelding 336.4 19/w 80 4/0 '6/1 8,350 1548 1494.3 370 280
 
6201 ALLOY NEUTRAL-MESSENGER
Bay 6 Solid 45 6 7 1,110 145 140 75 60
French Coach 6 7/w 45 6 7 1,110 155 144.3 75 60
German Coach 4 Solid 45 4 7 1,760 214 208.3 100 80
Arabian 4 7/w 45 4 7 1,760 229 214.4 100 80
Belgian 2 7/w 45 2 7 2,800 344 323.1 135 105
Shetland 1/0 19/w 60 1/0 7 4,460 546 521.1 180 140
Thoroughbred 2/0 19/w 60 2/0 7 5,390 670 641.5 205 160
Trotter 3/0 19/w 60 3/0 7 6,790 825 791.8 235 185
Walking  4/0 19/w 60 4/0 7 8,560 1019 979.7 275 210

XLPE Insulated Aluminium Conductor Service Drop Aerial Bundle ABC Cable

T8-2T Dual-Head LED Grow Tube

Dual-Head LED Grow Tube,Indoor Grow Box,LED Light Box,Advertising Light Box

LED Bulb Light Co., Ltd. , http://www.nbgrowlights.com

Posted on