600/1000V Steel Wire Armoured 300mm2 XLPE Cable

Model NO.: 300MM2 XLPE Cable
Wire Core Material: Red Copper Wire
Certification: ISO, CCC, SGS
Model: Yxv-U, Yxv-R, N2xy Cu/XLPE/PVC
Brand: Hongda
Standard: IEC 60502
Rated Voltage: 0.6/1 Kv
Trademark: Hongda
Transport Package: Drum or as Customer Require
Specification: 1.5mm2 to 400mm2
Origin: China
HS Code: 8544492100
Model NO.: 300MM2 XLPE Cable
Wire Core Material: Red Copper Wire
Certification: ISO, CCC, SGS
Model: Yxv-U, Yxv-R, N2xy Cu/XLPE/PVC
Brand: Hongda
Standard: IEC 60502
Rated Voltage: 0.6/1 Kv
Trademark: Hongda
Transport Package: Drum or as Customer Require
Specification: 1.5mm2 to 400mm2
Origin: China
HS Code: 8544492100
600/1000V steel wire Armoured 300MM2 XLPE Cable

Structure 

600/1000V Steel Wire Armoured 300mm2 XLPE Cable

 

Standard for 300mm2 XLPE cable 

Hongda 300mm2 XLPE cable is manufactured according to the standard of GB12706 or IEC,BS,DIN and ICEA upon request.

 

Applications for 300mm2 XLPE cable 

XLPE cable is suitable for dynamic line transmission and distribution lines of shielding performance requirements more stringent,especially applies to the rated voltage 0.6/1kV and below frequency inverter control system for power supply or connectiing cables.Frequency conversion cable is actually a shield-type power cable,the difference is that ground wires are divided into third part placed in the three main line between core to uniform electric field and improve levels of electromagnetic radiation of cable.Mostly used in high-power inverter power supply and frequency conversion motor connection

 

Operating characteristics for 300mm2 XLPE cable
1.Rated power-frequency voltage Uo/U of electrical cable : 0.6/1kV
2.Max.permissible continuous operating temperature of electrical cable conductor: 90°C
3.Max.short-circuit temperature of electrical cable conductor shall not exceed 250°C.(5s maximum)
4.The ambient temperature under installation should not below 0°C
5.The bending radius of electrical cable should not less than 15 times of electrical cable diameter.

 

The type of 300mm2 XLPE cable

Chinese Type

Description of xlpe insulated cable

Core qty

Conductors range

YJV

Copper conductor, xlpe insulated cable, PVC outer sheath Power Cable

1,  2,  3,  4, 3+1,

5,  4+1, 3+2

1.5~800mm2

YJY

Copper conductor, XLPE insulated cable, PE outer sheath Power Cable

1,  2,  3,  4, 3+1,

5,  4+1, 3+2

1.5~800mm2

ZA-YJV

ZB-YJV

ZC-YJV

Copper conductor, XLPE insulated flame-retardant Power Cable

1,  2,  3,  4, 3+1,

5,  4+1, 3+2

1.5~800mm2

WDZA-YJY

WDZB-YJY

WDZC-YJY

Copper conductor, XLPE insulated cable of Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) flame-retardant Power Cable

1,  2,  3,  4, 3+1,

5,  4+1, 3+2

1.5~800mm2

NH-YJV

Copper conductor, XLPE insulated cable of fire-resistant Power Cable

1,  2,  3,  4, 3+1,

5,  4+1, 3+2

1.5~800m


600/1000V Steel Wire Armoured 300mm2 XLPE Cable

 
DIMENSIONS
Cores
number
N°
Cross
section
mm²
Approx
conductor
diameter
mm
Insulation
medium
thickness
mm
Min. sheath
thickness
mm
Max.
external
diameter
mm
Electric
resistance at
20°C
ohm/km
Approx
cable weight
kg/km
Current
carrying
air free
A
Current
carrying
burried
A
Single core
1x 1.5 1.4 0.7 1.09 6.6 12.1 45 24 31
1x 2.5 1.8 0.7 1.09 7 7.41 55 33 41
1x 4 2.25 0.7 1.09 7.6 4.61 75 45 59
1x 6 3.05 0.7 1.09 8.2 3.08 100 58 74
1x 10 3.8 0.7 1.09 9.2 1.83 140 80 101
1x 16 4.7 0.7 1.09 10.5 1.15 205 107 128
1x 25 5.9 0.9 1.09 12.5 0.727 315 138 144
1x 35 7.1 0.9 1.09 13.5 0.524 400 169 174
1x 50 8 1 1.09 15 0.387 530 207 206
1x 70 9.6 1.1 1.09 17 0.268 725 268 254
1x 95 11.4 1.1 1.18 19 0.193 985 328 301
1x 120 13.1 1.2 1.18 21 0.153 1260 382 343
1x 150 14.6 1.4 1.26 23 0.124 1520 441 387
1x 185 16.5 1.6 1.26 25.5 0.0991 1940 506 434
1x 240 18.4 1.7 1.35 28.5 0.0754 2310 599 501
1x 300 21.1 1.8 1.43 31 0.0601 3200 693 565
1x 400 23.5 2 1.52 34.2 0.047 3931 - 639
1x 500 26.5 2.2 1.6 38 0.0366 5020 - 713
1x 630 30.1 2.4 1.69 44 0.0286 5324 - 785
Two cores
2x 1.5 1.4 0.7 1.43 10.5 12.1 115 26 37
2x 2.5 1.8 0.7 1.43 11.5 7.41 145 36 48
2x 4 2.25 0.7 1.43 13 4.61 195 49 63
2x 6 3.05 0.7 1.43 14 3.08 265 63 80
2x 10 3.8 0.7 1.43 16 1.83 390 86 104
2x 16 4.7 0.7 1.43 18.5 1.15 560 115 136
2x 25 5.9 0.9 1.43 22 0.727 850 149 173
2x 35 7.1 0.9 1.43 24.5 0.524 1080 185 208
Three cores

We offer various small type components for FTTH installation such as braching clip, bare fiber protection tubing, ftth drop cable protection tubes and boxes and so on. The branching clip is used to branch fiber cables. And we have many other fiber optic accessories such as thermo tube, fiber optic protective sleeve, fiber optic splice tray and holder for fiber protective sleeves. ftth drop cable protection tubes, also known as optical fiber protection tube, bare fiber protective tube made of low density polyethylene (LDPE) direct extrusion molding, mainly used for optical cable connector box, optical distribution frame, optical fiber segment and junction box bare fiber maintenance exposed peel. Can be used to maintain bare fiber without damage, not easy to damage. Branch off clip is casted by aluminum and coated by high temperature adhesive, molded by EVA and PA hot melt. This product is used for jointing with cables. This divided into two or three branches up to good breaking up.




Other Ftth Components

Splice Box,Fiber Patch Panel,Fiber Optic Distribution Box,Fiber Box

Chengdu XingXingRong Communication Technology Co.,Ltd , http://www.xxrtx.net

Posted on