12kv-35kv Aluminum Conductor XLPE / HDPE Single Core Sac Cable

  • Model NO.: 95mm2 120mm2
  • Conductor Type: Stranded
  • Conductor Material: Aluminum
  • Insulation Material: XLPE
  • Range of Application: Mine
  • Brand: Huatong
  • Factory Area: 100000mm2
  • Trademark: Huatong
  • Specification: Aluminium 1350 and XLPE
  • HS Code: 8544601200
  • Type: Insulated
  • Application: Overhead, Underground
  • Sheath Material: Crosslinking
  • Material Shape: Round Wire
  • Certification: ISO9001, CCC
  • Standard: ANSI/Icea S-66-524 or IEC
  • QC: 25
  • Transport Package: Wood Drum or Steel- Wood Drum
  • Origin: China
12kv-35kv Aluminum Conductor XLPE / HDPE Single Core SAC Cable

Description
XLPE insulated or covered aerial cable without or with conductor screen, the phase conductor may be AAC or AAAC or ACSR or Copper.
 
Operating Characteristics
Operating voltage: 10kV 15kv 24kv 25kv 35kv
Max. permissible continuous operating temperature of conductor with XLPE insulation: 90°C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250°C
The ambient temperature under installation should not be lower than: -20°C
The bending radius of cable is recommended as following:
Single core cable: not less than 20 times of the diameter of cable
Multi-core cable: not less than 15 times of the diameter of cable
 
Application
XLPE insulated aerial cable as a new-type aerial cable is used for overhead electric power transmission and distribution, extensively used in rebuilding of urban and forest region electrified wire netting. It improves the safety and reliance of electrified wire netting.
 
Manufacturing Standards
GB/T 14049-2008, IEC 60502-2,  ICEA S-66-524 / MEA


IF YOUR HAVE ANY INTERESTED PRODUCTS, PLS FEEL FREE TO CONTACT OUR SALES TEAM.

 
 
Conductor Thickness of conductor  Screen mm  (Average) Thickness
 of  insulation
mm  (Nominal)
Thickness
 of  Jacket mm  (Nominal)
Overall Diameter
 
Mm
(Approx.)
Conductor resistance at 20°C
 
Ω/km
(Max.)
Insulation resistance at 15.6°C
 
MΩ*km
(Min.)
Conductor Weight Breaking strength
 
N
(Min)
Current rating in free air at 40°C ambient A
 
Cable weight
 
Kg/km
(Approx.)
Cross-
sectional
area
mm2
(Nominal)
Number
 of o
 wires
 (Min.)
Diameter
 of i
conductor
mm
(Approx.)
35 6 6.88 0.3 3.175 3.175 21.0 0.868 2580 94 5591 150 381  
50 6 7.92 0.3 3.175 3.175 22.0 0.641 2380 128 7313 181 438  
70 12 9.55 0.3 3.175 3.175 23.5 0.443 2126 185 10420 225 527  
95 15 11.27 0.3 3.175 3.175 25.5 0.320 1913 256 14098 275 636  
120 15 12.68 0.3 3.175 3.175 27.0 0.253 1759 324 18518 319 734  
150 15 14.05 0.3 3.175 3.175 28.0 0.206 1648 398 22457 362 838  
185 30 15.75 0.3 3.175 3.175 30.0 0.164 1521 500 58974 418 970  
240 30 18.23 0.3 3.175 3.175 32.5 0.125 1367 655 37506 497

12kv-35kv Aluminum Conductor XLPE / HDPE Single Core Sac Cable12kv-35kv Aluminum Conductor XLPE / HDPE Single Core Sac Cable12kv-35kv Aluminum Conductor XLPE / HDPE Single Core Sac Cable12kv-35kv Aluminum Conductor XLPE / HDPE Single Core Sac Cable12kv-35kv Aluminum Conductor XLPE / HDPE Single Core Sac Cable12kv-35kv Aluminum Conductor XLPE / HDPE Single Core Sac Cable

Single Burner

Gas Stove,Gas Burner,Gas Cooker

Stainless Steel Gas Hob,Tempered Glass Gas Hob Co., Ltd. , http://www.nsgasstove.com

Posted on