18/30 Kv Rhz1-Ol Low Fire Hazard Cables for Power Distribution

Model NO.: Low Fire Hazard Cables
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, SGS
Model: Rhz1-Ol
Brand: Hongda
Conductor: Class 2 Stranded Aluminium Conductor
Inner Semi-Conductive Layer: Semi-Conductive Material
Insulation: XLPE (Cross-Linked Polyethylene)
Outer Semi-Conductive Layer: Semi-Conductive Material
Screen: Copper Wires
Sheath: PVC (Polyvinyl Chloride)
Trademark: Hongda Cable
Transport Package: Steel & Wooden Drum
Specification: 16mm2 to 400mm2
Origin: Made in China
HS Code: 8544601200
Model NO.: Low Fire Hazard Cables
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, SGS
Model: Rhz1-Ol
Brand: Hongda
Conductor: Class 2 Stranded Aluminium Conductor
Inner Semi-Conductive Layer: Semi-Conductive Material
Insulation: XLPE (Cross-Linked Polyethylene)
Outer Semi-Conductive Layer: Semi-Conductive Material
Screen: Copper Wires
Sheath: PVC (Polyvinyl Chloride)
Trademark: Hongda Cable
Transport Package: Steel & Wooden Drum
Specification: 16mm2 to 400mm2
Origin: Made in China
HS Code: 8544601200
18/30 kV RHZ1-OL Low Fire Hazard Cables for Power Distribution

EXCELLENT RHZ1-OL (AS) Al / Cu

CONSTRUCTION
 
18/30 Kv Rhz1-Ol Low Fire Hazard Cables for Power Distribution
CONDUCTOR Aluminium / Copper, semi-rigid class 2
INSULATION Cross-linked polyethylene (XLPE)
SCREEN Copper wire helicoidal layer
SHEATH LSOH compound
VOLTAGE 18/30 kV
STANDARDS HD 620-10E - Design and testing standard
IEC 60332-1-2 - Flame retardant (single wire)
IEC 60332-3-23 - Fire retardant (bunched wires) cat. B
IEC 60754 - Halogen free. Low acidity and corrosivity of evolved gases
IEC 61034 - Low opacity of evolved fumes

APPLICATIONS AND MAIN CHARACTERISTICS
Cables for power distribution for high voltage installed in air.

Abrasion and tear-resistant jacket. Easier slide. Shielding with lengthways shutter against water penetration.
Low fire hazard cable: flame and fire retardant, halogen-free, low acidity and corrosiveness of gases and low opacity of smoke emitted during combustion.

Electrical Characteristics
Dimensions
No. of Cores Nominal Cross Sectional Area Nominal Weight
mm² (Cu) kg/km (AL) kg/km
1 150 3450 2570
1 185 3875 2755
1 240 4545 3080
1 300 5240 3360
1 400 6175 3785
1 500 7290 4195
1 630 8860 4875

Why Choose Us ?
1. We have a large production base, and advanced production equipment 
2. Have an competitive price and high quality
3. Excellent after-sale service
4. Free issue:packaging list,invoice
5. Powerful technology team
6. Strict quality assurance system and perfect testing means
7. Advanced process equipment
8. Delivery on time
9. Our cable sales to Middle East,Africa,Russia,Southeast Asia, etc.
10.We have a good reputation in the overseas
0.6/ 1kv Cu XLPE Swa PVC Armoured Power Cable

FAQ
Q: Are you trading company or manufacturer ?
A: We are factory.

Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock,
it is according to quantity.

Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.

Q: What is your terms of payment ?
A: 30% T/T in advance,70% T/T balance before shipment


4. PACKAGE:
18/30 Kv Rhz1-Ol Low Fire Hazard Cables for Power Distribution

5. Related Products:
NA2XS(FL)2Y Aluminium Conductor XLPE PE- 18/30 (36)kV Cable
NA2XS(FL)2Y Aluminium Conductor XLPE PE-12/20 (24)kV Cable
NA2XS(FL)2Y Aluminium conductor XLPE PE-6/10 (12)kV Cable
NA2XS(F)2Y Aluminium Conductor XLPE PE - 18/30k (36)kV Cable
NA2XS(F)2Y Aluminium Conductor XLPE PE - 12/20 (24)kV Cable
NA2XS(F)2Y Aluminium Conductor XLPE PE - 6/10 (12)kV Cable
NA2XS2Y Aluminium Conductor XLPE PE - 18/30k (36)kV Cable
NA2XS2Y Aluminium Conductor XLPE PE - 12/20 (24)kV Cable
NA2XS2Y Aluminium Conductor XLPE PE - 6/10 (12)kV Cable
N2XS(FL)2Y - 12/20 (24)kV Cable
N2XS(FL)2Y - 6/10 (12)kV Cable
N2XS(F)2Y - 18/30 (36)kV Cable
N2XS(F)2Y XLPE PE - 12/20 (24)kV Cable
N2XS(F)2Y XLPE PE - 6/10 (12)kV Cable
N2XS2Y XLPE PE - 18/30 (36)kV Cable
N2XS2Y XLPE PE - 12/20 (24)kV Cable
N2XS2Y XLPE PE - 6/10 (12)kV Cable
NA2XSY Aluminium Conductor XLPE PVC - 18/30 (36)kV Cable
NA2XSY Aluminium Conductor XLPE PVC - 12/20 (24)kV Cable
NA2XSY Aluminium Conductor XLPE PVC - 6/10 (12)kV Cable
N2XSEY XLPE PVC - 6/10 (12)kV Cable
N2XSY XLPE PVC - 18/30 (36)kV Cable
N2XSY XLPE PVC - 12/20 (24)kV Cable
N2XSY XLPE PVC - 6/10 (12)kV Cable
BS 6622 XLPE MDPE 6.35/11 (12)kV Cable
BS 6622 XLPE PVC 6.35/11 (12)kV Cable
BS 7835 XLPE LSZH 6.35/11 (12)kV
BS 7835 XLPE LSZH 19/33 (36)kV
BS 6622 XLPE PVC 19/33 (36)kV

For more information, don't hesitate to call us on +86-15838290725 or get in touch via WhatsApp or Wechat with this phone number.
18/30 Kv Rhz1-Ol Low Fire Hazard Cables for Power Distribution
18/30 Kv Rhz1-Ol Low Fire Hazard Cables for Power Distribution 18/30 kV RHZ1-OL Low Fire Hazard Cables for Power Distribution

EXCELLENT RHZ1-OL (AS) Al / Cu

CONSTRUCTION
 
18/30 Kv Rhz1-Ol Low Fire Hazard Cables for Power Distribution
CONDUCTOR Aluminium / Copper, semi-rigid class 2
INSULATION Cross-linked polyethylene (XLPE)
SCREEN Copper wire helicoidal layer
SHEATH LSOH compound
VOLTAGE 18/30 kV
STANDARDS HD 620-10E - Design and testing standard
IEC 60332-1-2 - Flame retardant (single wire)
IEC 60332-3-23 - Fire retardant (bunched wires) cat. B
IEC 60754 - Halogen free. Low acidity and corrosivity of evolved gases
IEC 61034 - Low opacity of evolved fumes

APPLICATIONS AND MAIN CHARACTERISTICS
Cables for power distribution for high voltage installed in air.

Abrasion and tear-resistant jacket. Easier slide. Shielding with lengthways shutter against water penetration.
Low fire hazard cable: flame and fire retardant, halogen-free, low acidity and corrosiveness of gases and low opacity of smoke emitted during combustion.

Electrical Characteristics
Dimensions
No. of Cores Nominal Cross Sectional Area Nominal Weight
mm² (Cu) kg/km (AL) kg/km
1 150 3450 2570
1 185 3875 2755
1 240 4545 3080
1 300 5240 3360
1 400 6175 3785
1 500 7290 4195
1 630 8860 4875

Why Choose Us ?
1. We have a large production base, and advanced production equipment 
2. Have an competitive price and high quality
3. Excellent after-sale service
4. Free issue:packaging list,invoice
5. Powerful technology team
6. Strict quality assurance system and perfect testing means
7. Advanced process equipment
8. Delivery on time
9. Our cable sales to Middle East,Africa,Russia,Southeast Asia, etc.
10.We have a good reputation in the overseas
0.6/ 1kv Cu XLPE Swa PVC Armoured Power Cable

FAQ
Q: Are you trading company or manufacturer ?
A: We are factory.

Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock,
it is according to quantity.

Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.

Q: What is your terms of payment ?
A: 30% T/T in advance,70% T/T balance before shipment


4. PACKAGE:
18/30 Kv Rhz1-Ol Low Fire Hazard Cables for Power Distribution

5. Related Products:
NA2XS(FL)2Y Aluminium Conductor XLPE PE- 18/30 (36)kV Cable
NA2XS(FL)2Y Aluminium Conductor XLPE PE-12/20 (24)kV Cable
NA2XS(FL)2Y Aluminium conductor XLPE PE-6/10 (12)kV Cable
NA2XS(F)2Y Aluminium Conductor XLPE PE - 18/30k (36)kV Cable
NA2XS(F)2Y Aluminium Conductor XLPE PE - 12/20 (24)kV Cable
NA2XS(F)2Y Aluminium Conductor XLPE PE - 6/10 (12)kV Cable
NA2XS2Y Aluminium Conductor XLPE PE - 18/30k (36)kV Cable
NA2XS2Y Aluminium Conductor XLPE PE - 12/20 (24)kV Cable
NA2XS2Y Aluminium Conductor XLPE PE - 6/10 (12)kV Cable
N2XS(FL)2Y - 12/20 (24)kV Cable
N2XS(FL)2Y - 6/10 (12)kV Cable
N2XS(F)2Y - 18/30 (36)kV Cable
N2XS(F)2Y XLPE PE - 12/20 (24)kV Cable
N2XS(F)2Y XLPE PE - 6/10 (12)kV Cable
N2XS2Y XLPE PE - 18/30 (36)kV Cable
N2XS2Y XLPE PE - 12/20 (24)kV Cable
N2XS2Y XLPE PE - 6/10 (12)kV Cable
NA2XSY Aluminium Conductor XLPE PVC - 18/30 (36)kV Cable
NA2XSY Aluminium Conductor XLPE PVC - 12/20 (24)kV Cable
NA2XSY Aluminium Conductor XLPE PVC - 6/10 (12)kV Cable
N2XSEY XLPE PVC - 6/10 (12)kV Cable
N2XSY XLPE PVC - 18/30 (36)kV Cable
N2XSY XLPE PVC - 12/20 (24)kV Cable
N2XSY XLPE PVC - 6/10 (12)kV Cable
BS 6622 XLPE MDPE 6.35/11 (12)kV Cable
BS 6622 XLPE PVC 6.35/11 (12)kV Cable
BS 7835 XLPE LSZH 6.35/11 (12)kV
BS 7835 XLPE LSZH 19/33 (36)kV
BS 6622 XLPE PVC 19/33 (36)kV

For more information, don't hesitate to call us on +86-15838290725 or get in touch via WhatsApp or Wechat with this phone number.
18/30 Kv Rhz1-Ol Low Fire Hazard Cables for Power Distribution
18/30 Kv Rhz1-Ol Low Fire Hazard Cables for Power Distribution

USB Cables

USB Cables,Printer Cable,Data Cables

Electronic Wire Harness Co., Ltd. , http://www.nsusbcables.com

Posted on