80W High Power Integrated Solar Garden Outdoor LED Street Light

Model NO.: LED Solar Street Light Hxxy-Issl-80
Input Voltage: 12v
With Light Source: With Light Source
LED Chips Brand: Bridgelux
Product Name: LED Solar Street Light Hxxy-Issl-80
Solar Panel Max Power: 18V110W (Mono-Crystalline Silicon)
Solar Panel Life Time: 25 Years
Battery Type: Lithium Battery 12.8V/56ah
Battery Life Time: 5 Years
Charge Time: 10 Hours(in Strong Enough Sunshine)
Colour Temperature: 6000K-6500K
Mounting Height: 9-10m
Space Between Light: 40-50m
Warranty: 2 Years
Trademark: HXXY
Transport Package: Neutral Carton Box
Specification: 1260*425*160mm
Origin: Shenzhen, China
HS Code: 9405409000
Model NO.: LED Solar Street Light Hxxy-Issl-80
Input Voltage: 12v
With Light Source: With Light Source
LED Chips Brand: Bridgelux
Product Name: LED Solar Street Light Hxxy-Issl-80
Solar Panel Max Power: 18V110W (Mono-Crystalline Silicon)
Solar Panel Life Time: 25 Years
Battery Type: Lithium Battery 12.8V/56ah
Battery Life Time: 5 Years
Charge Time: 10 Hours(in Strong Enough Sunshine)
Colour Temperature: 6000K-6500K
Mounting Height: 9-10m
Space Between Light: 40-50m
Warranty: 2 Years
Trademark: HXXY
Transport Package: Neutral Carton Box
Specification: 1260*425*160mm
Origin: Shenzhen, China
HS Code: 9405409000
80W High Power Integrated Solar Garden Outdoor Led Street Light 


80W High Power Integrated Solar Garden Outdoor LED Street Light

 
Solar Street Light Specification:
 
Integrated Solar Street light (80W) Model:  HXXY-ISSL-80
Solar Panel Max Power 18V110W (mono-crystalline silicon)
Life Time 25 Years
Battery Type Lithium Battery 12.8V/56AH
Life Time 5 Years
LED Lamp
(with PIR sensor)     
Max Power 12V 80W
LED Chip Brand Bridgelux from USA with high brightness
Lumen (LM) 8000-8800lm
Life Time 50000hours
Viewing Angle 120°
Charge Time by sun 10 hours(in strong enough sunshine)
Discharge Time Saving power mode > 24 hours, 3 rainy days backup
Working Temperature Range( ºC ) -20ºC~+70ºC
Colour Temperature Range(k)     6000K-6500K        
Mounting Height Range (m) 9-10m
Space Between Light Range (m) 40-50m
Lamps Material Aluminium Alloy
Certificate CE / ROHS / IP65
Warranty 2 years


Solar Street Light Main Features:

1. New all-in-on design                                 
2. High efficiency monocrystalline solar panel
3. High brightness LED made in USA                    
4. PIR intelligent sensor
5. Humanized timing function                             
6. Multi-function high-tech controller
7. High quality Lithium Battery                            
8. From 6w-80w for choice
9. Security installation design                            
10. Special heat dissipation case
11. Professional waterproof design                       
12. With CE,RoHS,IP68 Certificate
13. 3 years long warranty

 
80W High Power Integrated Solar Garden Outdoor LED Street Light
 

Solar Street Light Application:

1. Courtyard / Garden/Park / Street / Roadway

2. Pathway / Parking Lot / Private Road / Sidewalk / Public Square

3. Plaza / Campus / Airfield / Farm & Ranch / Perimeter Security , Front yard , Back yard
 
4. Wildlife Area / Remote Area / Camping ,and much more

80W High Power Integrated Solar Garden Outdoor LED Street Light
 
About The Solar Street Light:

1. Integrated solar street light  our patent products which are popular using in the wide open area,street,garden,farm,seaside ,desert and so on places which with rich sunlight and  lack of electricity power areas..

2. It including the led lamp,solar panel,PIR remotion sensor,lithium battery into to one single product, and there is no any lines,it's very practical and convenient.

3. Inside the light,there is a controller,it will control the solar panel to charge the battery in the daytime,also it will control the led lamp to light up in the night.Also it have a PIR sensor,because of the sensor the led will light up as 30% brightness in the whole night,only when people close to the light,it will light up as 100%,after people left it will keep light as 30%,as it work as this way can save the power.

4. And this light we have from 8w to 60w different models with different solar panel and battery,the charge time is around 6-8hours,it means it need about 6-8 hours for the solar panel to make the battery full charged.After full charged it will support the LED lamp to work around 36 hours considering 3-5 rainy days. 

80W High Power Integrated Solar Garden Outdoor LED Street Light
 
Solar Street Light Motion sensor:

The Solar Street light with motion sensor is an intelligent outdoor lighting system that provides powerful lighting into an all-in-one compact package and is easy to install. During the day the highly efficient solar panel collects energy from the sun and stores that power in the advanced lithium battery. At night the powerful LED's automatically turn on providing ambient light for all to enjoy. When motion is detected the super bright LED's increase in brightness to provide an abundance of extra lighting for anyone in the area.After 45 seconds or when motion is no longer detected, the light drops down in brightness to conserve power.This intelligent feature allows The Solar Powered Streetlight to save power when no one is in range or utilizing the light, meaning a much longer run time than you would expect from a similar size solar lighting. The motion sensor is the practical way to enjoy brighter than normal light when extra lighting is needed.

Our Company:

Shenzhen hxxy tech. co. Ltd was founded in 2009. Belonging to hxxy tech. (Hong Kong) Co. Ltd, is a professional research and development, production, sales as one integrated enterprise.

Main products: solar street lights, solar module and small expert power generation system, solar garden light, solar lamp, solar lantern lamp. Solar application products; LED series products: LED fluorescent lamp, LED landscape lighting lamp and so on.

Especially the integrated solar street / garden light, it designed with solar panel, battery, controller lamp and other accessories are all integrated in one box. It' S easy to carry, simple to installed, convenient to use, saving energy, durable and long life span. With all this advantages, Its the best seller all over the world. Besides ours have more competitive price and Production capacity. 

Our goal is to make the solar light more simplification, rural industrialization, urbanization and international. 

We are sincerely looking forward to establishing long-term and friendly business relationship with you.

 
80W High Power Integrated Solar Garden Outdoor LED Street Light
Solar Street Light Packing:

Product size: 1260*425*160mm    
Product weight: 25kg    
Packing box: Neutral Carton Box    
Carton size: 1350*500*220mm    
Q'ty/ctn: 1pcs/ctn    
GW.for carton: 28kg 
   
Packs Containers: 20GP, 180pcs     40GP, 380pcs 
 

Our Services:

1) Send your inquiry, and we will reply you within 24 hours.
2) Well-trained and experienced staffs to answer all your inquires in fluent English or Spanish.
3) OEM and ODM can accept, and any of your customized lightings we can do it for you to sucess finished the the new design put into production.
4) As our new customers, We will offer you the unique design and some our current models to support.
5) We will do our best to protection of your sales area, and ideas of the design and all your private information, we will give you our best support, any interested, welcome to contact with us any time if you need any help.

80W High Power Integrated Solar Garden Outdoor LED Street Light
 
FAQ:

Q:Can I have a sample order?
A:Yes, we welcome sample order to test and check quality.Mixed samples are acceptable with many peices in stock.

Q:What is the lead time?
A:Samples need 3-5 working days, mass products need 7-10 days.

Q:How do you ship the goods and how long does it take arrive?
A:Express(DHL,UPS,Fedex or TNT.), Air or Sea shipment is available depends on your need.It usually takes 3-5 days to arrive except Sea transportation.

Q:How to precede the order if I have logo to print?
A:Firstly, we will prepare artwork for visual confirmation, and next we will produce a real sample for your second confirmation.If mockup is ok, finally we  will go to mass production.

Q:How to deal with the faulty?
A:Firstly, our defective rate is less than 0.2%, so there is no big problem to the lights.Secondly, we usually offer 2 years warranty for our lights.Thirdly.During the guarantee period, we will resend new lights with the new order for small quantity.If there are many lights don't work, we can repair them, then resend them to you.
80W High Power Integrated Solar Garden Outdoor Led Street Light 


80W High Power Integrated Solar Garden Outdoor LED Street Light

 
Solar Street Light Specification:
 
Integrated Solar Street light (80W) Model:  HXXY-ISSL-80
Solar Panel Max Power 18V110W (mono-crystalline silicon)
Life Time 25 Years
Battery Type Lithium Battery 12.8V/56AH
Life Time 5 Years
LED Lamp
(with PIR sensor)     
Max Power 12V 80W
LED Chip Brand Bridgelux from USA with high brightness
Lumen (LM) 8000-8800lm
Life Time 50000hours
Viewing Angle 120°
Charge Time by sun 10 hours(in strong enough sunshine)
Discharge Time Saving power mode > 24 hours, 3 rainy days backup
Working Temperature Range( ºC ) -20ºC~+70ºC
Colour Temperature Range(k)     6000K-6500K        
Mounting Height Range (m) 9-10m
Space Between Light Range (m) 40-50m
Lamps Material Aluminium Alloy
Certificate CE / ROHS / IP65
Warranty 2 years


Solar Street Light Main Features:

1. New all-in-on design                                 
2. High efficiency monocrystalline solar panel
3. High brightness LED made in USA                    
4. PIR intelligent sensor
5. Humanized timing function                             
6. Multi-function high-tech controller
7. High quality Lithium Battery                            
8. From 6w-80w for choice
9. Security installation design                            
10. Special heat dissipation case
11. Professional waterproof design                       
12. With CE,RoHS,IP68 Certificate
13. 3 years long warranty

 
80W High Power Integrated Solar Garden Outdoor LED Street Light
 

Solar Street Light Application:

1. Courtyard / Garden/Park / Street / Roadway

2. Pathway / Parking Lot / Private Road / Sidewalk / Public Square

3. Plaza / Campus / Airfield / Farm & Ranch / Perimeter Security , Front yard , Back yard
 
4. Wildlife Area / Remote Area / Camping ,and much more

80W High Power Integrated Solar Garden Outdoor LED Street Light
 
About The Solar Street Light:

1. Integrated solar street light  our patent products which are popular using in the wide open area,street,garden,farm,seaside ,desert and so on places which with rich sunlight and  lack of electricity power areas..

2. It including the led lamp,solar panel,PIR remotion sensor,lithium battery into to one single product, and there is no any lines,it's very practical and convenient.

3. Inside the light,there is a controller,it will control the solar panel to charge the battery in the daytime,also it will control the led lamp to light up in the night.Also it have a PIR sensor,because of the sensor the led will light up as 30% brightness in the whole night,only when people close to the light,it will light up as 100%,after people left it will keep light as 30%,as it work as this way can save the power.

4. And this light we have from 8w to 60w different models with different solar panel and battery,the charge time is around 6-8hours,it means it need about 6-8 hours for the solar panel to make the battery full charged.After full charged it will support the LED lamp to work around 36 hours considering 3-5 rainy days. 

80W High Power Integrated Solar Garden Outdoor LED Street Light
 
Solar Street Light Motion sensor:

The Solar Street light with motion sensor is an intelligent outdoor lighting system that provides powerful lighting into an all-in-one compact package and is easy to install. During the day the highly efficient solar panel collects energy from the sun and stores that power in the advanced lithium battery. At night the powerful LED's automatically turn on providing ambient light for all to enjoy. When motion is detected the super bright LED's increase in brightness to provide an abundance of extra lighting for anyone in the area.After 45 seconds or when motion is no longer detected, the light drops down in brightness to conserve power.This intelligent feature allows The Solar Powered Streetlight to save power when no one is in range or utilizing the light, meaning a much longer run time than you would expect from a similar size solar lighting. The motion sensor is the practical way to enjoy brighter than normal light when extra lighting is needed.

Our Company:

Shenzhen hxxy tech. co. Ltd was founded in 2009. Belonging to hxxy tech. (Hong Kong) Co. Ltd, is a professional research and development, production, sales as one integrated enterprise.

Main products: solar street lights, solar module and small expert power generation system, solar garden light, solar lamp, solar lantern lamp. Solar application products; LED series products: LED fluorescent lamp, LED landscape lighting lamp and so on.

Especially the integrated solar street / garden light, it designed with solar panel, battery, controller lamp and other accessories are all integrated in one box. It' S easy to carry, simple to installed, convenient to use, saving energy, durable and long life span. With all this advantages, Its the best seller all over the world. Besides ours have more competitive price and Production capacity. 

Our goal is to make the solar light more simplification, rural industrialization, urbanization and international. 

We are sincerely looking forward to establishing long-term and friendly business relationship with you.

 
80W High Power Integrated Solar Garden Outdoor LED Street Light
Solar Street Light Packing:

Product size: 1260*425*160mm    
Product weight: 25kg    
Packing box: Neutral Carton Box    
Carton size: 1350*500*220mm    
Q'ty/ctn: 1pcs/ctn    
GW.for carton: 28kg 
   
Packs Containers: 20GP, 180pcs     40GP, 380pcs 
 

Our Services:

1) Send your inquiry, and we will reply you within 24 hours.
2) Well-trained and experienced staffs to answer all your inquires in fluent English or Spanish.
3) OEM and ODM can accept, and any of your customized lightings we can do it for you to sucess finished the the new design put into production.
4) As our new customers, We will offer you the unique design and some our current models to support.
5) We will do our best to protection of your sales area, and ideas of the design and all your private information, we will give you our best support, any interested, welcome to contact with us any time if you need any help.

80W High Power Integrated Solar Garden Outdoor LED Street Light
 
FAQ:

Q:Can I have a sample order?
A:Yes, we welcome sample order to test and check quality.Mixed samples are acceptable with many peices in stock.

Q:What is the lead time?
A:Samples need 3-5 working days, mass products need 7-10 days.

Q:How do you ship the goods and how long does it take arrive?
A:Express(DHL,UPS,Fedex or TNT.), Air or Sea shipment is available depends on your need.It usually takes 3-5 days to arrive except Sea transportation.

Q:How to precede the order if I have logo to print?
A:Firstly, we will prepare artwork for visual confirmation, and next we will produce a real sample for your second confirmation.If mockup is ok, finally we  will go to mass production.

Q:How to deal with the faulty?
A:Firstly, our defective rate is less than 0.2%, so there is no big problem to the lights.Secondly, we usually offer 2 years warranty for our lights.Thirdly.During the guarantee period, we will resend new lights with the new order for small quantity.If there are many lights don't work, we can repair them, then resend them to you.

Apple Iphone Soft Silicone Case

Anti-Gravity iPhone Case.Anti-Gravity iPhone Cover,Anti-Gravityiphone Bag

Electric Battery, Rechargeable Mosquito Swatter, Mosquito Repellent Bands Co., Ltd. , http://www.nsmosquitorepellent.com

Posted on