8AWG Copper Conductor PVC Insulation Nylon Sheath Thhn

Model NO.: 8AWG THHN
Material Shape: Round Wire
Range of Application: Household
Certification: UL
Brand: Rneda
Standard: UL 83 Standard
Insulation: PVC
Sheath: Nylon
Core Number: Single Core
Price: Factory Price
Temperature: 90c Dry Only
Cross Section: 14AWG-1000kcmil
Transport Package: Soft Package
Specification: 18AWG -1000kcmil
Origin: China
Model NO.: 8AWG THHN
Material Shape: Round Wire
Range of Application: Household
Certification: UL
Brand: Rneda
Standard: UL 83 Standard
Insulation: PVC
Sheath: Nylon
Core Number: Single Core
Price: Factory Price
Temperature: 90c Dry Only
Cross Section: 14AWG-1000kcmil
Transport Package: Soft Package
Specification: 18AWG -1000kcmil
Origin: China
Professional OEM manufacturer
Top ten cable manufactuer in China
Leading ESP cable manufacture , largest Rubber cable manufacturer in China.
With UL,TUV,KEMA,CE,BV,PSB,SABA certifications
With TUV TYPE TESTING REPORT
With ISO9001,ISO18001,OHSAS18001 syetem certifications


 
8AWG copper conductor PVC insulation nylon sheath  THHN 
  • Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electric Code
  • When used as a type THHN conductor it is suitable for use in dry locations that are not to exceed temperatures of 90ºC
  • THHN copper conductors are annealed (soft) copper
  • Heat-, moisture-, gasoline- and oil-resistant

General purpose building wire for services, feeders and branch circuits.

 Temperature rating not to exceed:

 THHN/THWN: 90°C dry and dump, 600V

 THHN/THWN: 75 °C wet or in oil, 600V

 THWN-2: 90°C Dry, wet or in oil,600V   

 

2. Construction:

Conductor: Annealed Copper, solid or stranded sizes 14AWG up to 1000MCM

Insulation: Premium Grade Flame Retardant Polyvinyl Chloride( PVC)

Jacket: Tough Polyamide (Nylon)

 

 3. Standard&Test Specification:

 THHN/THWN-2 Conforms to following standards:

UL83 for Thermoplastic Insulated Wire and Cables(THHN/THWN-2)

UL758 for Appliance Wiring Materials(AWM)

UL1063 for Machine Tool Wire(MTW)(Stranded Conductor Only).

4.  Insulation

 

 Each conductor shall be insulated with PVC and sheathed with nylon complying with requirements of UL Standard 83 for Types THHN or THWN , UL Standard 1063 for Type MTW and CSA C22 .2 No. 75 for T90 Nylon . In addition, Types THWN or THHN shall comply with the optional Gasoline and Oil Resistant II rating of UL Standard 83. The insulation on stranded sizes shall also comply with UL requ irements for 105°C Appliance Wiring Material.

 

 The average thickness of PVC insulation, for a given conductor size , shall be as specified in UL Standard 83 for Types THWN or THHN. The minimum thickness at any point, of the PVC insulation, shall be not less than 90% of the specified average thickness. The minimum thickness at any point of the nylon sheath, shall be as specified in UL Standard 83 for Types THWN or THHN . The PVC insulation shall be appl ied tightly to the conductor and shall be free-stripping .

TDS about THHN

Size Section Cu Cond. PVC Thick  Nylon Thick OD
AWG mm2  Wire No. mm mm mm
14 2.08 7 0.38 0.1 2.8
12 3.31 7 0.38 0.1 3.3
10 5.26 7 0.51 0.1 4.2
8 8.37 7 0.76 0.13 5.5
6 13.3 7 0.76 0.13 6.5
4 21.2 7 1.02 0.15 8.2
3 26.7 7 1.02 0.15 8.9
2 33.6 7 1.02 0.15 9.8
1 42.4 7 1.27 0.18 11.3

Company information:
Established in 1993, Hebei Huatong Wires and Cables Group Co., Ltd covers an area more than 220,000 square meters, owning more than 420 sets manufacturing equipment and more than 250 sets of testing equipment or apparatus. Our annual production capacity is 3 billion Chinese Yuan. Now there are more than 800 employers in our company, among which more than 150 are technicians. Our products are widely used in the field of electric power, coal, metallurgy, petrochemical industry, railway, national defense, construction, aviation and other national key projects.

Products: XLPE insulating power cables with voltage up to 35kV, PVC insulated power cables, mining cable, general rubber sheathed flexible cable, Submersible oil pump cable,locomotivevehicle cables, elevator cable,shipboard cable, nuclear station cables, prefabricated branch cables, ABC cables, control cables, special cables, the motor winding connecting conductors, aluminum stranded conductor (AAC) and aluminum stranded steel-core reinforced conductor (ACSR) so on.

 We are JV with Furukawa(Japanese company) for rubber serial cable (minding cables, welding cables.submersible oil pump cables, .)and also JV with Riken(Japanese company) for elevator cables. Our products have extensive influence and good reputation in both domestic and worldwide market, such as the United States, Holland, Italy, Russia, Britain, Australia, New Zealand, Ethiopia, Ghana, Algeria, South Africa,Congo, Middle East and Southeast Asia countries and so on. 

8AWG Copper Conductor PVC Insulation Nylon Sheath Thhn
8AWG Copper Conductor PVC Insulation Nylon Sheath Thhn
8AWG Copper Conductor PVC Insulation Nylon Sheath Thhn
8AWG Copper Conductor PVC Insulation Nylon Sheath Thhn

Certification:

8AWG Copper Conductor PVC Insulation Nylon Sheath Thhn

FAQ:

(1)When can I get the price?

We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, pleasecall us or tell us in your e-mail so that we will regard your inquiry priority.

(2).How can I get a sample to check your quality?

After price confirmation, you can require for samples to check our quality. Sample is free, but the freightcharge should be paid.

(3).How long can I expect to get the sample?

After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express account or prepay us if you do not have an account.

(4).What about the lead time for mass production?

Honestly, it depends on the order quantity and the season you place the order.The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.

(5)What  cables does Hua Tong manufature?XLPE insulating power cables with voltage up to 35kV, PVC insulated power cables, mining cable, general rubber sheathed flexible cable, Submersible oil pump cable, locomotive vehicle cables, elevator cable,shipboard cable, nuclear station cables, prefabricated branch cables, ABC cables, control cables, special cables, the motor winding connecting conductors, aluminum stranded conductor (AAC) and aluminum stranded steel-core reinforced conductor (ACSR) so on.

 (6). Which payment terms do you accept?

 

A: The payment term varies with different price level and total value of every contract.

 

The following are most common terms:

 

a.100% TT advance for small amount orders.

 

b.30% T/T down payment, balance payment negotiable accordingly.

Professional OEM manufacturer
Top ten cable manufactuer in China
Leading ESP cable manufacture , largest Rubber cable manufacturer in China.
With UL,TUV,KEMA,CE,BV,PSB,SABA certifications
With TUV TYPE TESTING REPORT
With ISO9001,ISO18001,OHSAS18001 syetem certifications


 
8AWG copper conductor PVC insulation nylon sheath  THHN 
  • Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electric Code
  • When used as a type THHN conductor it is suitable for use in dry locations that are not to exceed temperatures of 90ºC
  • THHN copper conductors are annealed (soft) copper
  • Heat-, moisture-, gasoline- and oil-resistant

General purpose building wire for services, feeders and branch circuits.

 Temperature rating not to exceed:

 THHN/THWN: 90°C dry and dump, 600V

 THHN/THWN: 75 °C wet or in oil, 600V

 THWN-2: 90°C Dry, wet or in oil,600V   

 

2. Construction:

Conductor: Annealed Copper, solid or stranded sizes 14AWG up to 1000MCM

Insulation: Premium Grade Flame Retardant Polyvinyl Chloride( PVC)

Jacket: Tough Polyamide (Nylon)

 

 3. Standard&Test Specification:

 THHN/THWN-2 Conforms to following standards:

UL83 for Thermoplastic Insulated Wire and Cables(THHN/THWN-2)

UL758 for Appliance Wiring Materials(AWM)

UL1063 for Machine Tool Wire(MTW)(Stranded Conductor Only).

4.  Insulation

 

 Each conductor shall be insulated with PVC and sheathed with nylon complying with requirements of UL Standard 83 for Types THHN or THWN , UL Standard 1063 for Type MTW and CSA C22 .2 No. 75 for T90 Nylon . In addition, Types THWN or THHN shall comply with the optional Gasoline and Oil Resistant II rating of UL Standard 83. The insulation on stranded sizes shall also comply with UL requ irements for 105°C Appliance Wiring Material.

 

 The average thickness of PVC insulation, for a given conductor size , shall be as specified in UL Standard 83 for Types THWN or THHN. The minimum thickness at any point, of the PVC insulation, shall be not less than 90% of the specified average thickness. The minimum thickness at any point of the nylon sheath, shall be as specified in UL Standard 83 for Types THWN or THHN . The PVC insulation shall be appl ied tightly to the conductor and shall be free-stripping .

TDS about THHN

Size Section Cu Cond. PVC Thick  Nylon Thick OD
AWG mm2  Wire No. mm mm mm
14 2.08 7 0.38 0.1 2.8
12 3.31 7 0.38 0.1 3.3
10 5.26 7 0.51 0.1 4.2
8 8.37 7 0.76 0.13 5.5
6 13.3 7 0.76 0.13 6.5
4 21.2 7 1.02 0.15 8.2
3 26.7 7 1.02 0.15 8.9
2 33.6 7 1.02 0.15 9.8
1 42.4 7 1.27 0.18 11.3

Company information:
Established in 1993, Hebei Huatong Wires and Cables Group Co., Ltd covers an area more than 220,000 square meters, owning more than 420 sets manufacturing equipment and more than 250 sets of testing equipment or apparatus. Our annual production capacity is 3 billion Chinese Yuan. Now there are more than 800 employers in our company, among which more than 150 are technicians. Our products are widely used in the field of electric power, coal, metallurgy, petrochemical industry, railway, national defense, construction, aviation and other national key projects.

Products: XLPE insulating power cables with voltage up to 35kV, PVC insulated power cables, mining cable, general rubber sheathed flexible cable, Submersible oil pump cable,locomotivevehicle cables, elevator cable,shipboard cable, nuclear station cables, prefabricated branch cables, ABC cables, control cables, special cables, the motor winding connecting conductors, aluminum stranded conductor (AAC) and aluminum stranded steel-core reinforced conductor (ACSR) so on.

 We are JV with Furukawa(Japanese company) for rubber serial cable (minding cables, welding cables.submersible oil pump cables, .)and also JV with Riken(Japanese company) for elevator cables. Our products have extensive influence and good reputation in both domestic and worldwide market, such as the United States, Holland, Italy, Russia, Britain, Australia, New Zealand, Ethiopia, Ghana, Algeria, South Africa,Congo, Middle East and Southeast Asia countries and so on. 

8AWG Copper Conductor PVC Insulation Nylon Sheath Thhn
8AWG Copper Conductor PVC Insulation Nylon Sheath Thhn
8AWG Copper Conductor PVC Insulation Nylon Sheath Thhn
8AWG Copper Conductor PVC Insulation Nylon Sheath Thhn

Certification:

8AWG Copper Conductor PVC Insulation Nylon Sheath Thhn

FAQ:

(1)When can I get the price?

We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, pleasecall us or tell us in your e-mail so that we will regard your inquiry priority.

(2).How can I get a sample to check your quality?

After price confirmation, you can require for samples to check our quality. Sample is free, but the freightcharge should be paid.

(3).How long can I expect to get the sample?

After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express account or prepay us if you do not have an account.

(4).What about the lead time for mass production?

Honestly, it depends on the order quantity and the season you place the order.The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.

(5)What  cables does Hua Tong manufature?XLPE insulating power cables with voltage up to 35kV, PVC insulated power cables, mining cable, general rubber sheathed flexible cable, Submersible oil pump cable, locomotive vehicle cables, elevator cable,shipboard cable, nuclear station cables, prefabricated branch cables, ABC cables, control cables, special cables, the motor winding connecting conductors, aluminum stranded conductor (AAC) and aluminum stranded steel-core reinforced conductor (ACSR) so on.

 (6). Which payment terms do you accept?

 

A: The payment term varies with different price level and total value of every contract.

 

The following are most common terms:

 

a.100% TT advance for small amount orders.

 

b.30% T/T down payment, balance payment negotiable accordingly.

  • UNIQUE AND COMPACT DESIGN. This Aroma Diffuser is coated with wood grain, which makes it look very natural and primitive. With compact and portable design, the cap of the aroma diffuser is easy to take off, you won`t bother to unscrew the cap with great force when your hands is wet. Just gently take off the cap, add water and essential oil, enjoy high-quality life.
  • LARGE CAPACITY AND GREAT MIST OUTPUT. This aroma diffuser can hold up to 300ml of water and produce up to 30ml of moisture per hour. It can run up to 10 hours of continuous output. Automatic power off when water used up, which ensures safety.
  • SUPER QUIET. Adopted ultrasonic technology, this diffuser is extremely quiet when working. It gives out ultra fine and smooth mist which can soften and moisten dry and chapped skin in winter. It also helps you breathe better when your are sleeping with air conditioner on.
  • ADJUSTABLE LED LIGHT. You can choose among 7 colors between two mode: steady on/changing color. Each color is adjustable between bright and dim.The soft light creates romantic atmosphere which helps you escape the hustle and bustle of modern life.
  • TIME SETTING. 4 time setting modes:1 hour/3 hours/6 hours/steady on. Note: this is an Essential Oil Diffuser, but you also can use it as a Humidifier if you like.

Aroma Diffuser

Aroma Diffuser,Electric Oil Diffuser,Mini Aroma Diffuser

Shenzhen Hygea Technology Co.,Ltd , http://www.hygeaaromadiffuser.com

Posted on