Africa Solar Energy Saving Solar Powered Street Lamps

Model NO.: BR-H15 solar powered street lamps
Input Voltage: 12V/24V
With Light Source: With Light Source
LED Chips Brand: Bridgelux
LED Lamp: 9W to 120W
Solar Street Light Pole: 3m-12m Hot Galvanized Pole
Solar Battery: 100ah-250ah Gel Battery
Solar Controller: 15A/20A 12V/24V PWM
Battery Place: Hang on The Pole
Warranty: 3 Years,5 Years
Average Life: >8000h,8000h
OEM ODM: Yes
IP Level: IP67
Pole Height: 3m to 12m Street Light Pole
Trademark: Bright, BR Solar, AS Solar
Transport Package: Carton & Pallet
Specification: 9W to 120W solar powered street lamps
Origin: China
HS Code: 85414020
Model NO.: BR-H15 solar powered street lamps
Input Voltage: 12V/24V
With Light Source: With Light Source
LED Chips Brand: Bridgelux
LED Lamp: 9W to 120W
Solar Street Light Pole: 3m-12m Hot Galvanized Pole
Solar Battery: 100ah-250ah Gel Battery
Solar Controller: 15A/20A 12V/24V PWM
Battery Place: Hang on The Pole
Warranty: 3 Years,5 Years
Average Life: >8000h,8000h
OEM ODM: Yes
IP Level: IP67
Pole Height: 3m to 12m Street Light Pole
Trademark: Bright, BR Solar, AS Solar
Transport Package: Carton & Pallet
Specification: 9W to 120W solar powered street lamps
Origin: China
HS Code: 85414020
Africa solar energy saving solar powered street lampsAfrica Solar Energy Saving Solar Powered Street Lamps
Product Specification
4.0KWH Design, Lighting Time: 11-12 Hours/Nights*3-5 Overcast Weather
Pole height 6M 6M 8M 8M
LED Lamps 20W 30W 45W 60W
Solar Panel 110W*1PC 80W*2PC 120W*2PC 150W*2PC
Solar Battery 100Ah/12V*1PC 150Ah/12V*1PC 120Ah/12V*2PC 150Ah/12V*2PC
Battery Box(Optional) Engineering Steel Engineering Steel Engineering Steel Engineering Steel
Battery Box(Optional) Engineering Plastic Engineering Plastic Engineering Plastic Engineering Plastic
Solar Controller 10A/12V 15A/12V 10A/24V 15A/24V
Packing:40'HQ 150 Units 130 Units 100 Units 90 Units
 
5.0KWH Design, Lighting Time: 11-12 Hours/Nights*3-5 Overcast Weather
Pole height 6M 6M 8M 8M
LED Lamps 20W 30W 45W 60W
Solar Panel 90W*1PC 65W*2PC 90W*2PC 120W*2PC
Solar Battery 100Ah/12V*1PC 150Ah/12V*1PC 120Ah/12V*2PC 150Ah/12V*2PC
Battery Box(Optional) Engineering Steel Engineering Steel Engineering Steel Engineering Steel
Battery Box(Optional) Engineering Plastic Engineering Plastic Engineering Plastic Engineering Plastic
Solar Controller 10A/12V 15A/12V 10A/24V 10A/24V
Packing:40'HQ 150 Units 130 Units 100 Units 90 Units

Main Components Of Solar Powered Street Lamps
Africa Solar Energy Saving Solar Powered Street Lamps LED Street Lamp Producing Power 9W-250W
High Lumen:150-150LM/W;Lifespan:50000-100000Hrs
* Technical Descriptions
* Lamp Body: High-Pressure Die-Casting Aluminum. Corrosion Resistant,IP65 or IP68
* Application with Polyester Substance in its Surface.
* Reflector: High Purity Aluminum or Stainless Steel SS304,Mirror Polish.
* LED Cooler: Aluminum Material, Producing By Module
* Cover Glass: High Strength and High Transparent Toughened Glass
* Fastener Bolt and Screws: Stainless Steel, Anti-theft screw.
* Ambient Temp:-40~+50°C;Humidity:10%~95%
* Arm Diameter: 48 or 60mm
Solar Panel 18V/36V--Poly &Mono Silicon 5W-310W
* Before Production
-Control Of  Raw Material Before Use
-Data Recording Of  Raw Material---Products Tracebility
* During production
-Control At Each Step Of  Production
-Validation Of Each Step By Quality Controllers
* After production
-Systematic Flash Test On Each PV Modules
-Quality Control With IEC Compliance
-Tests In Our Facility Testing
-Optional: Third Party Inspection Before Shipment If Needing.
* Limited Warranty
-Workmanship for 5 years,90% of minimum power output over 12 years,80% over 20 years.
-The Solar Panels Are Manufactured In According To The IEC61215 Standards.Lifespan:20-25 Years
Solar Battery 24AH~250AH/12V
* Gelled battery, Sealed Type. Deep Cycle. Maintenance Free.
* Real Green Power
* Low Internal Resistance
* Low Self-discharging Rate
* Long-life Design
* Wider Temperature Range
* Extremely good discharge recovery ability
 Solar Charge Controller,IP68 Rating
* Intellectual Control Technology Based On MCU And Special Software.
* Adopt Tandem PWM Charge Control Method, So That The Voltage Loss Of Electrical Circuit Is Only The Half Of  Diode Charge, Charge Efficiency To Improve By 3% - 6%.
* The Over Discharging Recovery Control And Automatically Floating Charge Control Can Prolong The Battery Service Life.
* Battery Reverse Connection Protection, Over-voltage Protection And Under-voltage Protection.
* Solar Module Reverse Connection Protection.
* Automatically Recovery Output, Output Over Current Protection And Out Short Circuit Protection
* Intelligent Time Control System, It Can Set Up 1-15 Hours Timing Or Delay Time ( Set Period To Resume Current Output, Two Period Can Be Set.)
* Light Control, Time Control, Temperature Control
* High-precision Voltage Control For The Battery Safety Work.
* Waterproof Design.
Steel Pole From 3M-12M For Street Lighting. 15M-50M For High Mast Pole
* Material
-
Q345B/A572,Minimum Yield Strength>=345n/mm2
-Q235B/A36,Minimum Yield Strength>=235n/mm2
* Shape
-Round, Multi-pyramidal, Column form, Polygonal Or Conical
* Production Process
Raw Material Test→Cutting→Molding Or Bending →Welding (Longitudinal ) →Dimension Verify→Flange Welding→Hole Drilling →Calibration →Debur →Galvanization Or Powder Coating, Painting→Recalibration→Thread→Packaging
 
Advantage Of Solar Street Lighting Syatem
* Green Energy,Low Power Consumptiom,Save 60%~80% Than Others.
* Higher Power,Higher Brightness Intensity,Good Color Rendition.
* Save Electricity Cost,Save Electric Transformer And Cable Cost,Free Maintanenance.
* Environmental Impact---Eliminate Hazardous Disposal,Low Light Pollution,No Radiation.
* Longer Lifetime: Between 80000-100000 Hrs,If Lighting 12Hrs/Night Could Use At Least 12-22 Years.
* Less Heat Generated Compared To Other Sourses.
* Downward Orientation Of Light Could Adjust Lighting Angles And Lighting Range And Shape On The Ground To      Meet The Road-rectangular,Other Lighting Source Just Could Give Common Round Shape And Small Lighting        Range.


Different Solar Street Light Battery Box Design For ChoosingAfrica Solar Energy Saving Solar Powered Street Lamps
Africa Solar Energy Saving Solar Powered Street Lamps



 

 
Africa solar energy saving solar powered street lampsAfrica Solar Energy Saving Solar Powered Street Lamps
Product Specification
4.0KWH Design, Lighting Time: 11-12 Hours/Nights*3-5 Overcast Weather
Pole height 6M 6M 8M 8M
LED Lamps 20W 30W 45W 60W
Solar Panel 110W*1PC 80W*2PC 120W*2PC 150W*2PC
Solar Battery 100Ah/12V*1PC 150Ah/12V*1PC 120Ah/12V*2PC 150Ah/12V*2PC
Battery Box(Optional) Engineering Steel Engineering Steel Engineering Steel Engineering Steel
Battery Box(Optional) Engineering Plastic Engineering Plastic Engineering Plastic Engineering Plastic
Solar Controller 10A/12V 15A/12V 10A/24V 15A/24V
Packing:40'HQ 150 Units 130 Units 100 Units 90 Units
 
5.0KWH Design, Lighting Time: 11-12 Hours/Nights*3-5 Overcast Weather
Pole height 6M 6M 8M 8M
LED Lamps 20W 30W 45W 60W
Solar Panel 90W*1PC 65W*2PC 90W*2PC 120W*2PC
Solar Battery 100Ah/12V*1PC 150Ah/12V*1PC 120Ah/12V*2PC 150Ah/12V*2PC
Battery Box(Optional) Engineering Steel Engineering Steel Engineering Steel Engineering Steel
Battery Box(Optional) Engineering Plastic Engineering Plastic Engineering Plastic Engineering Plastic
Solar Controller 10A/12V 15A/12V 10A/24V 10A/24V
Packing:40'HQ 150 Units 130 Units 100 Units 90 Units

Main Components Of Solar Powered Street Lamps
Africa Solar Energy Saving Solar Powered Street Lamps LED Street Lamp Producing Power 9W-250W
High Lumen:150-150LM/W;Lifespan:50000-100000Hrs
* Technical Descriptions
* Lamp Body: High-Pressure Die-Casting Aluminum. Corrosion Resistant,IP65 or IP68
* Application with Polyester Substance in its Surface.
* Reflector: High Purity Aluminum or Stainless Steel SS304,Mirror Polish.
* LED Cooler: Aluminum Material, Producing By Module
* Cover Glass: High Strength and High Transparent Toughened Glass
* Fastener Bolt and Screws: Stainless Steel, Anti-theft screw.
* Ambient Temp:-40~+50°C;Humidity:10%~95%
* Arm Diameter: 48 or 60mm
Solar Panel 18V/36V--Poly &Mono Silicon 5W-310W
* Before Production
-Control Of  Raw Material Before Use
-Data Recording Of  Raw Material---Products Tracebility
* During production
-Control At Each Step Of  Production
-Validation Of Each Step By Quality Controllers
* After production
-Systematic Flash Test On Each PV Modules
-Quality Control With IEC Compliance
-Tests In Our Facility Testing
-Optional: Third Party Inspection Before Shipment If Needing.
* Limited Warranty
-Workmanship for 5 years,90% of minimum power output over 12 years,80% over 20 years.
-The Solar Panels Are Manufactured In According To The IEC61215 Standards.Lifespan:20-25 Years
Solar Battery 24AH~250AH/12V
* Gelled battery, Sealed Type. Deep Cycle. Maintenance Free.
* Real Green Power
* Low Internal Resistance
* Low Self-discharging Rate
* Long-life Design
* Wider Temperature Range
* Extremely good discharge recovery ability
 Solar Charge Controller,IP68 Rating
* Intellectual Control Technology Based On MCU And Special Software.
* Adopt Tandem PWM Charge Control Method, So That The Voltage Loss Of Electrical Circuit Is Only The Half Of  Diode Charge, Charge Efficiency To Improve By 3% - 6%.
* The Over Discharging Recovery Control And Automatically Floating Charge Control Can Prolong The Battery Service Life.
* Battery Reverse Connection Protection, Over-voltage Protection And Under-voltage Protection.
* Solar Module Reverse Connection Protection.
* Automatically Recovery Output, Output Over Current Protection And Out Short Circuit Protection
* Intelligent Time Control System, It Can Set Up 1-15 Hours Timing Or Delay Time ( Set Period To Resume Current Output, Two Period Can Be Set.)
* Light Control, Time Control, Temperature Control
* High-precision Voltage Control For The Battery Safety Work.
* Waterproof Design.
Steel Pole From 3M-12M For Street Lighting. 15M-50M For High Mast Pole
* Material
-
Q345B/A572,Minimum Yield Strength>=345n/mm2
-Q235B/A36,Minimum Yield Strength>=235n/mm2
* Shape
-Round, Multi-pyramidal, Column form, Polygonal Or Conical
* Production Process
Raw Material Test→Cutting→Molding Or Bending →Welding (Longitudinal ) →Dimension Verify→Flange Welding→Hole Drilling →Calibration →Debur →Galvanization Or Powder Coating, Painting→Recalibration→Thread→Packaging
 
Advantage Of Solar Street Lighting Syatem
* Green Energy,Low Power Consumptiom,Save 60%~80% Than Others.
* Higher Power,Higher Brightness Intensity,Good Color Rendition.
* Save Electricity Cost,Save Electric Transformer And Cable Cost,Free Maintanenance.
* Environmental Impact---Eliminate Hazardous Disposal,Low Light Pollution,No Radiation.
* Longer Lifetime: Between 80000-100000 Hrs,If Lighting 12Hrs/Night Could Use At Least 12-22 Years.
* Less Heat Generated Compared To Other Sourses.
* Downward Orientation Of Light Could Adjust Lighting Angles And Lighting Range And Shape On The Ground To      Meet The Road-rectangular,Other Lighting Source Just Could Give Common Round Shape And Small Lighting        Range.


Different Solar Street Light Battery Box Design For ChoosingAfrica Solar Energy Saving Solar Powered Street Lamps
Africa Solar Energy Saving Solar Powered Street Lamps



 

 

DG200 Double Roller Granulator

DG200 Double Roller Granulator,Fertilizer Granulator Machine,Fertilizer Making Machine

Dry Roll Press Granulator Co., Ltd. , http://www.nspelletmill.com

Posted on