Asphalt levitation tester use - Huaqiang Electronic Network

MOS power IC full range
Test - lowercase jpg
Kaixin micro test
Brand AVX TPSE226M035R0125 Low impedance tantalum capacitor AVX 22
Electronic scale crystal oscillator 3.2*2.5mm 3225 16M (16.000MHZ) 12PF 10PPM 20PPM 30PPM

Asphalt Levitation Tester

SYD-0631

Asphalt Levitation Tester

Standards and Applications:

The instrument is designed and manufactured in accordance with national industry standards, including JTJ052 "Testing Procedures for Asphalt and Asphalt Mixtures for Highway Engineering" and T0631 "Asphalt Floatation Test". It is used to measure the floatation of residues such as residue and coal tar after distillation of slow-setting liquid petroleum pitch.

The floatation degree of asphalt refers to the time it takes for a sample to soften and be washed away by water in a specified floater from sinking at a certain temperature. Unless otherwise stated, the test temperature for the residue after distillation of liquid petroleum pitch is 50°C, while for coal tar pitch it is either 32°C or 50°C.

The instrument can also function as a constant temperature water bath when not used for asphalt floatation testing.

SYD-0631

Asphalt Levitation Tester

Technical Specifications:

1. Working Power: AC 220V (-5% ~ +10%), 50Hz.

2. Water Bath Capacity: 370×300×300 mm (L×W×H).

3. Applicable Water Volume: 28L.

4. Heating Equipment: Electric heater, 1300W.

5. Cooling Equipment: New refrigeration compressor.

6. Temperature Control Range: 5°C ~ 80°C.

7. Temperature Control Accuracy: ±0.1°C.

8. Floating Disk: Wall thickness 1.4mm ± 0.1mm, weight 37.9g ± 0.2g.

9. Copper Tube: Wall thickness 1.4mm ± 0.1mm, weight 9.8g ± 0.2g.

10. Ambient Temperature: ≤30°C.

11. Relative Humidity: ≤85%.

12. Power Consumption: No more than 2000W.

13. Dimensions: 750×540×580 mm (L×W×H).

14. Net Weight: 30kg.

Custom Piezo Solutions

Yuhai company offer custom services including piezo ceramic elements and piezo transducers, Yuhai people work closely with individual customers to provide solutions. We offer engineering support services including material selection, component design assistance, device and system modeling and failure analysis.


We hope to be your best supplier with the elements of superior performance and reliability, lowest prices, most rapid delivery times and the best customer service.


IMG_0787

Ultrasonic Transducer,Piezo Transducer,Ultrasonic Distance Sensor,Piezoelectric Transducer

Zibo Yuhai Electronic Ceramic Co., Ltd. , https://www.yhpiezo.com

Posted on