Detailed introduction of the use of intelligent water dispenser

Introduction to intelligent water dispenser

The intelligent water dispenser is an environmentally friendly product. It is a high-tech energy-saving product specially designed for public places with a large number of drinking water, especially schools, factories and hospitals. The atmospheric pressure type intelligent water dispenser effectively solves the problem of high drinking water cost. Health, long water waiting time. The atmospheric pressure type intelligent water dispenser is equipped with advanced filtering device, which can effectively filter out residual chlorine, bacteria, sediment, rust, heavy metals, colloids and other impurities in the water to ensure the drinking water is hygienic, and then heat the water to boil, to achieve the standard of direct drinking. In line with the requirements of Chinese drinking water.

Intelligent water dispensers are characterized by health, power saving, safety, environmental protection and light weight. Today, drinking water safety is becoming more and more important. Atmospheric pressure intelligent water dispensers have been accepted and respected by people, becoming a new generation of healthy and environmentally friendly products. .

Detailed introduction of the use of intelligent water dispenser

Intelligent water dispenser features

â– Special high-efficiency heat exchanger, saving 80%;

â– With intelligent water control system, if the water does not open, it will flow out without water, avoid drinking raw water;

â– All stainless steel manufacturing, sink molding, ergonomic design;

â–  boiling water, warm water through multi-stage (PP + KDF + double efficient activated carbon + RO, etc.) commercial straight and high temperature sterilization treatment;

â– The atmospheric pressure patented technology design is safer.

Note: Applicable water pressure 0.05-0.6MPa, suitable for water source, urban tap water.

1. The filter medium filter has CCC (3C) certification, CQC certification, energy conservation and environmental protection invention patent certificates, national wading health and safety approval approval documents, ISO certification certificates, product certification inspection reports, etc., as well as obtaining various honors;

2. Independent research and development of heat exchange patents, energy saving of about 80% compared with ordinary water heaters; environmental protection and energy saving, all of the body are made of 304 food grade stainless steel (including shell, water bladder, faucet, bellows, etc.), atmospheric pressure heating water bladder, standard With three-stage ultrafiltration (also available for large drinking water equipment), it can be boiled, warm water (water temperature adjustable), direct drinking water, faucet 2-6 faucets (can be freely selected, can be equipped with lock control, can be equipped with IC card System), the water bladder can be selected 15L-60L (can choose a few liters freely), can also accept custom!

3, filter medium filter intelligent operation, digital meter display temperature, time switch function, high and low voltage protection function and over temperature protection function. The circuit board box has a high waterproof function; safety five anti-shock and anti-steam, anti-electric shock, anti-dry, anti-opening, fire retardant, automatic fault alarm. Let users use peace of mind;

4, filter in the filter drinking water sanitation, large amount of water, with the use of continuous, continuous supply, 24 hours continuous continuous water supply; no yin and yang water, no thousands of boiling water; no scaling, beautiful shape, long service life;

As a kind of electrical appliance, the safety of smart water dispenser is very important. Since the average consumer does not have the knowledge of electricity consumption, do not install it after purchasing the product. It is best to install it by the professional staff of the production company. Before using the product, consumers should carefully read the product instruction manual and follow the instructions.

Detailed introduction of the use of intelligent water dispenser

How to use the smart water dispenser : Plug in the power supply

Plug in the power supply in order to heat the bottled water, in order to allow the water to be disinfected again, if you want to drink cold water, you can not plug in the power, but the average family will use hot water.

Detailed introduction of the use of intelligent water dispenser

Step 2: Use the indicator light

The indicator light indicates whether the water in the water dispenser is hot or cool. When there is hot water in the water dispenser, the indicator light of the bottled water is yellow. If there is no hot water, the indicator light will become Red.

Detailed introduction of the use of intelligent water dispenser

Step three: hot water switch

The hot water switch is also very simple to use. Just bend the handle down to pour out the hot water, but the hot water will be hot, so be careful.

Detailed introduction of the use of intelligent water dispenser

Step 4: Cool water switch

The switch of cool water is controlled by the blue color of cool color. The blue head is used in the same way as above. If you like to drink cold water, you can press down the switch.

Detailed introduction of the use of intelligent water dispenser

Step 5: Switch of the water dispenser

Many people will ignore this switch button. In fact, if you want to save electricity, you have to turn off the red button when you don't need the water dispenser, so the water will not heat up all the time, and it will not consume electricity.

Detailed introduction of the use of intelligent water dispenser

Step 6: Use of bottled water

The choice of bottled water can also be more flexible, but to choose a good quality bottled water, you can look at the composition of the bottled water to choose, which is good for health.

Detailed introduction of the use of intelligent water dispenser

Precautions for using a smart water dispenser

Generally, the intelligent water dispenser should be placed on a firm platform, and there should be drainage floor drains nearby, which is convenient for the desktop drinking water platform to clean the sewage and overflow under fault conditions. Before the external power supply is connected to the water heater, a separate power switch and leakage protection device should be installed. The metal casing of the drinking platform should be reliably grounded. Consumers should pay attention to the following six aspects in their use:

1. Do not install the drinking platform in a damp environment, such as a bathroom. Because the air in the bathroom is humid, after the water vapor enters the electrical box, it is easy to condense on the surface of the insulating medium, reducing its insulation performance and causing leakage accidents.

2. When using the drinking water platform, you should first fill the water and then turn on the power. Do not adjust the temperature controller by yourself to prevent the temperature controller from being adjusted above the boiling temperature.

3. Do not easily remove the grounding conductor of the drinking platform during use, as grounding is the last protection against electric shock.

4. Always check the water source of the straight drink machine to prevent blockage at the water inlet and avoid the dry burning of the electric heating tube.

5. Regular descaling. If the local water quality is inferior, a water purifier can be installed at the water inlet of the drinking water platform to improve the working efficiency of the drinking water platform, prolong the service life and ensure the cleanliness of the drinking water.

6. The water source and power supply of the drinking platform must be cut off before servicing the drinking water platform. When cleaning the outer casing of the drinking water platform, wipe it with a clean rag. It is strictly forbidden to flush the outer casing and the electrical box with the jet of water.

Somke Machine

Fog Smoke Machine

Feature:
* DURABLE MATERIAL: It is made of top grade aluminum alloy, built-in fan for heat dissipation, stable and lightweight. Look upscale and durable for long time.
* BEAUTIFUL COLOR SHOW: It can choose single colors or color combinations. It will be great enjoyment to see the colorful light projected to the ceiling, wall and floor,etc.
* SUIT FOR VARIOUS OCCASION: Suit for various parties, birthday, dance, holiday, celebrations, Karaoke, family or friend home celebration. The laser light can be used in home, disco, living room, bar, club, or anywhere needed.
* EASY OPERATION: The light will enter sound activated mode, which makes the lights blink according to the beat of the music or sound. Adjustable motion speed.
* CREAT ATMOSPHERE EVERYWHERE: This laser light is mini size with tripod, portable and convenient for carry. You can place it everywhere.


Our company have 13 years experience of LED Display and Stage Lights , our company mainly produce Indoor Rental LED Display, Outdoor Rental LED Display, Transparent LED Display,Indoor Fixed Indoor LED Display, Outdoor Fixed LED Display, Poster LED Display , Dance LED Display ... In additional, we also produce stage lights, such as beam lights Series, moving head lights Series, LED Par Light Series and son on..

Somke Machine Series,Smoke Machine,Wedding Smoke Machine,Smoke Machine Party

Guangzhou Chengwen Photoelectric Technology co.,ltd , https://www.cwledpanel.com

Posted on