Light conversion technology innovation, accelerate the rise of intelligent lighting

LEDs are ubiquitous in our daily lives, finding their way into everything from high-definition TVs and automotive lighting to street lamps and home decor. Over the last few years, the cost of LEDs has steadily dropped, fueling the global LED lighting market's rapid expansion. However, we're now entering a new phase in the LED lighting industry, driven by next-generation optical technologies that offer enhanced comfort, safety, superior quality, and networked functionality at more affordable prices. Light Polymers, a San Francisco-based startup specializing in chemical materials, is reshaping the LED lighting sector with its innovative, patented water-based liquid crystal materials. Based in San Francisco, Light Polymers focuses on synthesizing aqueous liquid crystal materials for various applications. Currently, the company is leveraging these unique materials to develop new Crystallin products, which include architectural recessed lights, beauty lamps, LED lamps for red light therapy, plant growth lights, fish and animal growth lights, professional photography lights, and advanced personal lighting solutions. Notably, the recessed light products hit the Asian market via sales partners and online channels in August and made their debut in the U.S. in November. ![Light Conversion Technology Innovation](http://i.bosscdn.com/blog/22/25/46/10H-0.png) ▲ Crystallin Gold recessed lights installed in the office. "Light Polymers' advanced polymer technology stands apart from traditional fixed-color LED packaging methods," remarked Marc McConnaughey, CEO of Light Polymers, during an exclusive interview with LEDinside. "While light conversion technology isn't entirely new to the LED industry, its widespread adoption has been hindered by implementation challenges and cost concerns." In the past, high color rendering (CRI) lighting was primarily used in spaces requiring exceptional performance, such as museums. Light Polymers' water-based liquid crystal material technology enables lamps to produce comfortable and uniform light with a full color gamut (high CRI), minimal glare, and no UV leakage. Furthermore, because Light Polymers' materials reduce manufacturing expenses, these premium lighting products can compete in the market at a more accessible price point. ![Light Conversion Technology Innovation](http://i.bosscdn.com/blog/22/25/46/4437-1.png) ![Light Conversion Technology Innovation](http://i.bosscdn.com/blog/22/25/46/1145-2.png) "As our technology involves water-based liquid crystal materials with special properties that tightly encapsulate phosphors to maximize blue light conversion, we can utilize a range of low- and medium-power blue LEDs," explained Dr. Huang Zhihao of Light Polymers. "This eliminates costly binning or sorting processes and removes the need for expensive large heat sinks for high-brightness LEDs, significantly cutting costs. Lighting products developed with this technology experience fewer color shifts and brightness degradation, offering improved power efficiency compared to those using traditional packaging techniques." ### Mastering the Market Niche: Reasonable Prices for High-CRI LED Downlights Light Polymers' Crystallin downlights carve out a distinct niche within the fiercely competitive LED downlight market. These are the thinnest recessed lights available and deliver museum-grade lighting for both residential and commercial settings at an approachable price point. "We can design any spectrum within a few days," noted Zhang Jiarong, VP of Light Polymers. "We plan to introduce a custom service that provides tailored spectral phosphor films based on client requirements. The recessed light market is highly cost-sensitive, yet we believe there’s a demand for high-CRI recessed lights at reasonable prices." The 6-inch Crystallin Gold downlight boasts a high color rendering index (CRI > 98), with color temperatures of 3000K and 5000K, priced at an MSRP of $14.99. Other 6-inch products include Crystallin Red (designed to avoid sleep disruption), Crystallin Orange (ideal for light-sensitive environments like semiconductor factories), Crystallin Salon (customized for nail salons), and Crystallin Grow (a houseplant growth lamp). Light Polymers also offers Crystallin Custom services for personalized spectrum options. Additionally, the company has invested in multi-layer film development, boosting luminous efficiency by over 30% compared to conventional lamps. "At present, LED design efficiency has plateaued. To further enhance overall efficiency, the focus must shift toward developing more efficient optical components," stated McConnaughey. ![Crystallin Gold Downlight](http://i.bosscdn.com/blog/22/25/4A/1Z-3.png) ▲ Crystallin Gold downlight ### Thriving in the LED Plant Lighting Sector For LED lighting manufacturers, plant lighting represents a lucrative market segment. LEDinside predicts that the global LED plant lighting market will grow from $576 million in 2016 to $1.42 billion by 2020. "Light Polymers' chemical innovations facilitate the development of low-cost LED light conversion technology and offer novel approaches for creating plant lights," said Marc McConnaughey. "Existing LED processes struggle to tailor spectra to customer specifications efficiently, with lengthy production cycles. Our plant growth lamps are optimized for vertical farms, maximizing luminous efficacy and photon flux density (PPFD) while minimizing energy consumption. Using light conversion technology and inexpensive blue LEDs, we can deliver precise growth spectra as per customer needs." In the near future, Light Polymers will introduce GrowBlade light-conversion flat-panel lamps, available in 300x300mm, 300x600mm, 300x1200mm, and 300x1500mm sizes. Designed for indoor farms requiring a fixed spectrum while balancing low capital and operational costs, GrowBlades feature a uniform-glowing Crystallin film with a 3cm ultra-thin design, providing additional planting space and boosting productivity in vertical farms. Through extensive area illumination and specialized Crystallin Grow film spectrums, GrowBlades not only improve light quality but also increase crop yields. Field tests indicate that a single GrowBlade can replace two to three tubes of multi-color packaged LEDs. ![GrowBlade vs Multi-Colored LED Tubes](http://i.bosscdn.com/blog/22/25/4B/193-4.png) ▲ Light Polymers compares GrowBlade plant lights (above) with tubes using multiple single-frequency LED sources. As medical and recreational cannabis legalization spreads globally, it is expected to drive further demand for LED plant lighting. Light Polymers aims to capitalize on this niche market by helping plants achieve optimal growth through innovative plant lights and unique top-and-side lighting designs. ![GrowBlade on Vertical Farms](http://i.bosscdn.com/blog/22/25/4C/215-5.png) ▲ GrowBlade lamps equipped with Crystallin Grow film for use on vertical farms. ### Beauty Red LED Phototherapy Beyond LED downlights and plant lighting, Light Polymers plans to release beauty-focused red light therapy products this autumn. The company's advanced light conversion films employ low-cost blue LEDs to deliver red light for phototherapy at a fraction of the cost of earlier generations. Recently, Light Polymers demonstrated a 660nm phototherapy red light film. "Aqueous liquid crystal materials enable numerous high-performance professional applications at reasonable prices," said Ye Meijun, Asia Business Development Manager at Light Polymers. "High-end hotels are already reaching out to us, seeking installations to provide red light treatments for their guests." Red light therapy has received FDA approval for use in the U.S. Research by NASA shows that red light can alleviate muscle tension, promote gum regeneration, reduce wrinkles, and repair sun-damaged skin. Light Polymers' red light products come in 300x600mm and 300x1200mm sizes and are crafted with a modern consumer electronics aesthetic in mind. With these advancements, Light Polymers is paving the way for smarter, more efficient, and accessible lighting solutions across multiple industries.

Stylus Pen For IPad

Product catagories of Stylus Pen for ipad, which is just for iPad Versions 2018 & 2019 and above.

It can work on following:

iPad 6th 2018: A1893/A1954
iPad 7th 2019: A2197/A2198/A2200
iPad 8th 2020: A2270/A2428/A2429/A2430
iPad air 3rd: A2152/A2153/A2154/A2123
iPad Air 4th: A2072/A2316/A2324/2325
iPad mini 5th: A2124/A2125/A2126/A2133
iPad Pro 1st/2nd 11: A1980/A2013/A1934/A1979/A2228/A2068/A2230/A2231
iPad Pro 3rd/4th 12.9: A2069/A2229/A2233/A2232/A1876/A2014/A1895/A1983



Stylus Pencil For iPad,Stylus Pen,Stylus Pen For Drawing,Touch Pencil

Shenzhen Ruidian Technology CO., Ltd , https://www.wisonen.com

Posted on