Specification: 0.5-630 mm2
Origin: Guangdong, China
HS Code: 8544492100
Model NO.: YJV YJY YJV22 etc.
Wire Core Material: Copper/Aluminum Cable
Certification: ISO, CCC, CE
Model: Yjv Yjlv Yjy Yjly etc. Cable
Brand: Gdyg
Supply Record: America, Australia, African Countries, Arabian Co
Sepcial Applicaton: Low Smoke Power Cable
Key Word 1: PVC Power Cable
Fire Resistant: Yes
Aroumoured Type: Steel Wire, Aluminum Wire
Business Type: Manufacturer
Key Words: Armoured Cable
Key Word: Copper/Aluminum Cable
Standard: ISO, 3c, IEC,60502, IEC60227, an/Nz etc
Characters: Swa, Sta, Insulated Cable
Trademark: GDYG
Transport Package: Wooden Reel, Steel Reel etc.
Specification: 0.5-630 mm2
Origin: Guangdong, China
HS Code: 8544492100
Steel Wire Armoured Power Cable for Underground

Constrution Sketch
Steel Wire Armoured Power Cable for Underground


Characteristics & Applications
 
XLPE insulated power cable has the advantages of not only high mechanical strength, good ambient stress resistance, good electrical properties and anti-chemical corrosion, but also simple construction, light weight and convenient to use. It applies to electrical power trensmission and distribution lines with A.C. rated voltage U0/U up to and including 0.6/1kV.
The main feature of the flame retardant XLPE power cable is hard to get fire or that the continous burning of cables is vert limited when it is on fire. It applies to the places with many cable is laid tightly together such as power-generated station, subway, tunnel, hight-storey building, large-sized factory and mines, oil field and coal mine.


 
Standards
The products can be produced in accordance with GB, IEC, BS, and other standards.

 
Basic Information
Model No: YJV YJLV VV VLV VY VLY VV22 VV23 VV33 etc.            
Material Shape: Round Wire
Range of Application: Power Grid and All Industry  
Certificate: ISO9001,ISO14001, CCC, CE
Brand Name: GDYG 
Specification: 0.5mm2 - 630mm2          
Supply Record: America, Australia, African countries, Arabian countries, Asian countries etc.
Origin: Guangdong, China
Application: Power Grid, Transmission Line, Construction, Railway Transportation, Chemical Plant, Telecom , Oil Industry, Equipment Manufacture, Instrument Industry etc..
Voltage: 35KV, 10KV, 0.6/1KV, 450/750V, 300/500V
Current: AC & DC
Insulation Material: XLPE, PVC etc.
Sheath Material: XLPE, PVC etc.
Material Shape: Round wire


Application
1. the rated voltage U0/U is from 0.6/1kV to 26/35kV.
2. Maximum conductor temperature under normal operation is 90ºC.
3. Maximum conductor temperature under short circuit (Max duration is not more than 5s) is not more than 250ºC.
4. Minimum installation ambient temperature is not less than 0ºC.
   Installation bending radius are not less than the following specified values:
   Single core non-armored cable: 20D
   Single core armored cable: 15D
   3 cores non-armored cable: 15D
   3 cores armored cable: 12D
   (Note: D-outer diameter of cable)


Technical Parameters

Voltagela class    26/35kV
Type: YJV YJLV ZC-YJV ZC-YJLV
nominal cross-section
mm
insulation 
thickness mm
O.D.
mm
capacitance
μF/km
approx. 
ampacity (air)
 A
approx. 
ampacity buried 
A
reference weight 
of finished cable 
kg/km
Cu Al Cu Al Cu Al
50 10.5 38.8 0.12 245 190 225 175 1745 1435
70 10.5 40.7 0.13 305 235 275 215 2025 1591
95 10.5 42.3 0.15 370 285 330 255 2330 1742
120 10.5 43.9 0.16 425 330 375 290 2647 1903
150 10.5 45.5 0.17 485 375 420 325 2998 2068
185 10.5 47.3 0.18 555 430 475 370 3414 2218
240 10.5 49.7 0.19 650 505 555 430 4044 2556
300 10.5 51.9 0.21 745 580 630 490 4696 2836
400 10.5 55.3 0.23 870 680 720 565 5801 3320
500 10.5 60.3 0.25 1000 790 825 645 7132 4032
630 10.5 64.5 0.28 1160 920 940 740 8515 4609

Voltagela class    12/20kV
Type: YJV22 YJLV22 ZC-YJV22 ZC-YJLV22
nominal cross-section
mm
insulation 
thickness mm
O.D.
mm
capacitance
μF/km
approx. 
ampacity (air)
 A
approx. 
ampacity buried 
A
reference weight of finished cable 
kg/km
Cu Al Cu Al Cu Al
3X25 5.5 55.5 0.22  129 100 155 120 3833 3476
3X25 5.5 57.9 0.25  156 120 185 144 4313 3702
3X50 5.5 61.1 0.26  184 143 218 169 5281 4311
3X70 5.5 64.9 0.28  229 177 267 207 5878 4399
3X95 5.5 68.8 0.30  275 213 319 247 6867 4770
3X120 5.5 72.2 0.32  316 246 363 282 7906 5192
3X150 5.5 75.8 0.33  363 281 412 319 9045 5554
3X185 5.5 79.9 0.35  408 317 460 357 10435 6070
3X240 5.5 86.4 0.38  178 372

PS Frame

PS Frame,Mirror Frame,Picture Frame

Household Items,Primed Moulding,Ps Cornice Co., Ltd. , http://www.nshouseholditems.com

Posted on