T1.58 pursues the ultimate visual experience, easy to achieve 4k, 8k

In high-density (small pitch) applications, high-density LED display cabinets are getting lighter and lighter, thinner and thinner, and the density of lamps is getting higher and higher. The design pursues simplicity and fashion, supports pre-maintenance, and the visual experience is even more With continuous upgrades and so on, users' expectations for high-density LED display cabinets are getting higher and higher. Powerful giant color T1.58 cabinet is light to thin, high-end atmosphere, practical and convenient, the pursuit of the ultimate visual experience, easy to achieve 4k, 8k, to meet your illusions about high-density LED display box.

1.jpg

T1.58 products adopt die-cast aluminum box, direct 16:9 size design (505.6*284.4mm), golden ratio field of view display, easy to achieve 2K, 4K, 8k playback.

2.jpg

As the mainstream trend in the current market, T1.58 is of course at the forefront of technology. It adopts magnetic design, and the unit board is directly attached to the die-casting box. The bottom case is lighter and thinner, the flatness is better, and the front maintenance is more convenient.

3.jpg

Appearance, we pursue the ultimate simplicity, fashion atmosphere, all devices, interfaces, scientific layout, practical and aesthetics perfect integration.

4.jpg

On the weight, T1.58 single box weighs only 4.15kg, the thickness is only 26.5mm, light and portable; the buckle back cover structure design can be quickly removed and easy to maintain;

5.jpg

In order to realize the optical seamless splicing of the screen body, T1.58 adopts die-cast aluminum design and CNC machining, which has good display effect, physical heat dissipation, low temperature operation and no fan zero noise.

7.jpg

At the same time, it also adopts dual signal port design to protect the normal display of the screen;

8.jpg

In order to ensure the best display effect, T1.58 is equipped with high-definition high-order PWM driver IC, refresh rate ≥3840Hz, no water ripple, no flashing, no wording; can effectively eliminate ghosts, the first line is dark, open cross, etc. 14-16bit grayscale processing, the picture color scale is smoother, and the display effect is realistic and delicate. Not only that, its viewing angle can reach more than 160°, and the multi-directional viewing shows high quality and clear effect.

9.jpg

The T1.58 is a high-density product that combines light, thin, 16:9 size design, magnetic design, front-maintenance, dual-signal design, and high-definition high-end PWM driver ICs. Experience the gold display field, feel the ultra-clear, delicate and extreme visual feast, all in one, powerful giant color T1.58 high-density box, buy small-pitch LED large screen, find powerful giant color. For more product information, please consult the powerful giant office, provincial brand operator, and thousand store service provider.


Surge Protection Device SPD

Product Description


SPD Surge Protective Device,Lightning Surge Protector
Surge Protection Device (SPD)


It is a device used to limiting instant surge voltage and discharge surge current, it at least including a non-linear component.

Surge protective Device Model Selection

With the impact of international information flow, the rapid development of microelectronic science and technology, communication, computer and automatic control technology, make the building start to go for high quality, high functional area, formed a new building style-intelligent building. As inside the intelligent building there are lot of information system, <<Building lightning protection design norm>> GB50057-94(2002 vision)(hereafter brief as <<lightning protection norm>>) put forward the relative requirement to install the surge protective device, to ensure the information system safely and stable running.
SPD essentially is a equipotential connection material, its model selection is according to the different lightning protection area, different lightning electromagnetic pulse critical and different equipotential connection position, decide which kind of SPD used in the area, to achieve the equipotential connection with the common earth electrode. Our statement will based on SPD's maximum discharge current Imax, continuous operating voltage Uc, protection voltage Up, alarm mode etc.
As per << Lightning Protection Norm>> item 6.4.4 stipulation "SPD must can withstand the expected lightning current flow and should confirm to the additional two requirements: the maximum clamp voltage during surge across, capable to extinguish the power frequency follow-on current after lightning current across." That is the value of SPD's max. clamp voltage add its induction voltage of two ends should be same with the system's basic insulation level and the equipment allowed max. surge voltage.

SPD for Power Supply System Series Selection Guide

The installation of SPD at each lightning protection zone, according to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category, its insulation withstand impulse voltage level can determine the selection of SPD. According to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category as signal level, loading level, distribution and control level, power supply level. Its insulation withstand impulse voltage level are:1500V,2500V,4000V,6000V. As per to the protected equipment installation position different and the different lightning current of different lightning protection zone, to determine the installation position of SPD for power supply and the break-over capacity.
The installation distance between each level SPD should not more than 10m, the distance between SPD and protected equipment should as short as possible, not more than 10m. If due to limitation of installation position, can't guarantee the installation distance, then need to install decoupling component between each level SPD, make the after class SPD can be protected by the prior class SPD. In the low voltage power supply system, connecting an inductor can achieve the decoupling purpose.
SPD for power supply system specification selection principle
Max. continuous operating voltage: bigger than protected equipment, the system's max. continuous operating voltage.
TT System: Uc≥1.55Uo (Uo is low voltage system to null line voltage)
TN System: Uc≥1.15Uo
IT System: Uc≥1.15Uo(Uo is low voltage system to line voltage)
Voltage Protection Level: less than the insulation withstand impulse voltage of protected equipment
Rated discharge current: determined as per to the lightning situation of the position installed and lightning protection zone.
SP1 Series

Normal Working Conditions
-Altitude not exceed 2000m
-Ambient air temperature:
Normal range: -5ºC~+40ºC
Extend range: -40ºC~+80ºC
-Relative Humidity: 30% - 90% under indoor temperature condition
- At the place without obviously shaking and shock vibration
- Non-explosion danger medium, non-corrosion gas and dust ( including conductive dust)

Classification

-As per Nominal Discharge Current:
5,10,20,30,40,60KA(8/20µs)
- As per Maximum continuous operating voltage:
275V,320V,385V,420V,440V,460V
- As per to poles
1P,1P+N,2P,3P,3P+N,4P
- As per auxiliary functions:
a. With remote signal output ( remote alarm function)
b. Without remote signal output

Selection Principle

- The continuous applied voltage on the two terminals of SPD should not more than the maximum continuous operating voltage Uc value;
- The voltage protection level Up of SPD should less than the maximum impulse withstand voltage of the protected equipment;
- As per to the different earthing system and protection mode to select the specification accordingly;

Product Features

1, built-in over-current overheating, temperature control circuit technology.

2, the module design, easy installation, online replacement.

3, low leakage current, fast response time, low residual voltage.

4, alarm indication device, green (normal) v red (fault).

Model/Technical Parameters WR-B60 WR-B80 WR-B100 WR-B120 WR-B150
Rated Operating Voltage Un (V ~) 220V 380V 220V 380V 220V 380V 220V 380V 220V 380V
Maximum Continuous Operating Voltage Uc (V ~) kV 385V 420V 385V 420V 385V 420V 385V 420V 385V 420V
Voltage Protection Level Up (V ~) kV ≤1.8≤2.2 ≤2.4≤2.5 ≤2.5≤3.2 ≤3.4≤3.7 ≤4.0≤4.5

Maximum Discharge

Current Imax(8/μ20μs)kA

60 80 100 120 150

Nominal Discharge

Current In(8/μ20μs)kA

30 40 60 80 100
Response Time <25 <100
L/N(mm²)The Cross Section Of L/N Line 16,25 16,25 16,25 16,25 25,35
PE (mm²)The Cross Section Of PE Line 16,25 25,35 25,35 25,35 35
Fuse or Switch (A) 63A 63A 63A,100A 63A,100A 63A,125A
The Line Section of Communication and Alarm (mm²) ≥ 1.5

Operating

Environment-C

(-40ºC~-+85ºC)
Relative humidity 25 ºC ≤95%
installation Standard Rail35mm
Material of Outer Covering Fiber Glass Reinforced Plastic

Surge Protector SPD,Surge Protection Device SPD,SPD

Wenzhou Korlen Electric Appliances Co., Ltd. , https://www.korlenelectric.com

Posted on