Guide: LED Bold Light is a substitute for traditional halogen bristles and gold halide bristles. The times are developing, the products are always updated, and the updates are fast. The LED brilliance lamp replaces the traditional halogen bristles and the metal halide bristles, indicating that it has more advantages. So what is the LED stern lamp? What are the advantages of the LED blast lamp product, what are the precautions? Follow the Xiaobian to find out.
What is the LED Bold Light:
The LED stern lamp adopts a universal telescopic structure, including a lamp cap and a lamp holder body. The LED stern lamp lamp head is connected to the lamp holder body through a lamp holder, and the lamp holder is a "door" type, which is composed of a truss and two side edges; the truss is provided with a through hole, and is suspended by the lamp holder bolt The seat can be rotated 360 degrees around the bolt axial direction; the rails of the LED bristles are provided with guide rail slots, and each of the guide rail slots is provided with a corresponding telescopic foot movable along the left and right sides of the slot; the lamp cap is mounted on the two telescopic legs through the cap bolts At the end, the lamp cap can be rotated 360 degrees axially around the cap bolt. This series of LED bristles is based on the principle of telescopic universal direction, so that the luminaire can achieve double-sided steering or even 360-degree and up-and-down steering, and the shape made with a specific mold makes the steering pull smoother and safer. It also reduces material costs and makes operation more convenient.
What are the advantages of LED blazer products:
1. More power saving: LED bulb light is equivalent to 1/8~1/10 of the traditional gallbladder lamp (the electro-optic conversion rate of LED is more than 80%, halogen lamp and metal halide lamp are variants of incandescent lamp, The electro-optical conversion rate is about 20%, and the rest is consumed in fever.)
2. Longer service life: LED bristles have a service life of 30,000 to 50,000 hours under normal store lighting temperature. Halogen lamps are extremely heat-generating, have a short life span, and are extremely easy to burn. The replacement and maintenance costs of store lamps can be Straight down 5 to 10 times.
In particular, the use of the halogen lamp cup of the bladder lamp, low light efficiency, large light decay, short life, has become an outdated product, slowly withdraw from the market.
3.LED blast light cold light source, no radiation: LED is a cold light source, no heat radiation and ultraviolet radiation, will not cause damage to the display products. Halogen lamps and metal halide lamps emit heat radiation, which contains a large amount of ultraviolet radiation. It is easy to cause discoloration and discoloration of textiles, jewels and jade on long-term exposure.
Precautions:
1. LED bulb light rated voltage is AC100V-277V 50-60Hz. Long-term use of LED bristles in conditions where the voltage is too high or too low will affect the function and life of normal use;
2. LED bulbs should not be installed in flammable objects. Under no circumstances should the lamps be covered by insulating pads or similar materials;
3. When the LED bulb is installed and replaced, the power must be cut off to ensure personal safety;
4. When the LED stern lamp is abnormally working (self-extinguishing, flashing), please check the contact performance between the lamp holder and the lamp head and whether the power supply voltage is normal. If the normal fault is still not eliminated, replace the new lamp;
5. LED blazing lights are forbidden to be used outdoors and where the rain falls.
REMOTE CONTROL SOCKET
Important Safeguards
When using any electrical appliance, in order to reduce the risk of fire, electric shock and/or injury to persons, basic safety precautions should always be follow8d. including:
• The appliance is for household and indoor use only.
• Before plugging in. check that the voitage on the rating label is the same as the mains supply.
• To protect against electric shock, do not immerse any part of the product in water or other liquid.
• This socket is intended for use by competent adults only and children should be supervised at all times.
• Do not use the socket for other than its intended use.
• This socket can be used by children aged from 8 years arxl above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not p<ay with the appliance Cleaning and user maintenance shall M be made by children without supervision.
• Children of less than 3 years should be kept away unless continuously supervised.
Children from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in. regulate and clean the appliance or perform user maintenance.
• Don't use this socket in the immediate surroundings of a bath, a shower or a swimming pool.
• In case of malfunction, do not try to repair the socket yourself, it may result in a fire hazard or electric shock
Do Not Exceed Maximum a680W
Place the LR44 batteries provided into the compartment in the back of the Remote Control, please insert as sho*/m in the back of the compartment to ensure the polarity is correct.
Programming Instructions
• Plug the Remoce Socket$($)lnto the wall socket(s) and switch on the mams supply, the red LED will flash every second.
• If the LED is not flashing press & hold the manual ON/OFF button for 5 seconds until it Hashes
•Press any ON switch on the Remote Control for approximately 2 seconds and the Remote Socket(s) learn the code. The LED will stop flashing top confirm the codehas been accepted.
• Any number of Remote Sockets can be programmed to one Remote Control ON button to create multiple switching.
• To programme o<her Remote Sockets on different Remote Control ON buttons repeat the prevous steps
• If the mains supply is turned off the Remote Sockets v/ill lose their code and it wil be necessary to re-pcogramme.
Operation:
• Plug your appliance(s) into the Remote Socket(s)
• Press the programmed ON or OFF button on the Remote Control to control the Remote Socket.
♦ The Remote Sockets can also be operated manually using its ON/OFF Button Trouble shooting
If a Remote Socket does not react to the Remote Control please check the followng:
♦ Low battery in tbo Remote Control
• Distance too large between the remote control and the recerver (ensure the range distance is no more than 20 clear Metres) and free from obstacle that may reduce the distance.
• If programming has not been successful, tum the power off and back on then follow the programming steps above.
How to decode
• Press the manual ONX)FF button for 5 seconds until the red LED flashes once per
second to confirm de-coding is successful
♦ Press the ALL OFF switch on the Remote Control for more than 3 seconds, the LED
flashes once per second to confirm (decoding successful.
Voltage: 240V-/50HZ
Max power rating: 3680W max.
Remote frequency:
Remote range:
Battery Type:
433.92MHz
230 Metres
Button Cell 2x1.5V LR44 =
Please check with your local waste management service authority regarding regulations for the safe disposal of the batteries. The batteries should never be placed G municipal waste.
Use a battery d^posal facility if available
M
For eioctncal products sold within the European Community. At the end of the electrical products useful life, it should not be disposed of wth household waste. Please recycle faaMies exist. Check with your Local Authonty or retailer for recycling advice.
C€
remote socket,remote power socket,remote control plugs,remote plug socket
NINGBO COWELL ELECTRONICS & TECHNOLOGY CO., LTD , https://www.cowellsocket.com