Upstream chip technology has always been the bottleneck of domestic LEDs . Most of the core technologies are in foreign countries. The following describes the process of chip manufacturing:
LED chip inspection
Microscopic examination: whether there is mechanical damage on the surface of the material and whether the size and electrode size of the lockhill chip and the electrode size meet the process requirements.
2.LED expansion
Since the LED chip is still arranged with a small close spacing (about 0.1 mm) after dicing, it is not conducive to the operation of the post process. The film of the bonded chip is expanded by a spreader to stretch the pitch of the LED chip to about 0.6 mm. It can also be manually expanded, but it is easy to cause problems such as chip falling waste.
3.LED dispensing
Place silver glue or insulating glue on the corresponding position of the LED bracket. For GaAs, SiC conductive substrates, red, yellow, and yellow-green chips with back electrodes are made of silver paste. For blue and green LED chips of sapphire insulated substrates, insulating glue is used to fix the chips.
The difficulty of the process lies in the control of the amount of glue, and there are detailed technical requirements in the height of the glue and the position of the glue. Since silver glue and insulating glue have strict requirements in storage and use, the wake-up, stirring and use time of silver glue are all matters that must be paid attention to in the process.
4.LED preparation glue
In contrast to dispensing, the glue is applied to the back electrode of the LED with a glue machine, and then the LED with silver glue on the back is mounted on the LED holder. The efficiency of the preparation glue is much higher than that of the dispensing, but not all products are suitable for the preparation process.
5.LED hand-piercing
The expanded LED chip (with or without glue) is placed on the jig of the lancet table, and the LED holder is placed under the clamp, and the LED chips are punctured one by one under the microscope with a needle. Hand-made thorns have an advantage over automatic loading, making it easy to replace different chips at any time, for products that require multiple chips.
6.LED automatic mounting
The automatic loading is actually a combination of two steps of glue (dispensing) and mounting the chip. First, put silver glue (insulating glue) on the LED bracket, then use the vacuum nozzle to suck the LED chip to the moving position, and then place it in the The corresponding bracket position. In the process of automatic loading, the equipment should be familiar with the operation and programming of the equipment, and at the same time adjust the glue and installation accuracy of the equipment. In the selection of the nozzle, the bakelite nozzle should be used as much as possible to prevent damage to the surface of the LED chip. In particular, the blue and green chips must be made of bakelite. Because the steel nozzle will scratch the current diffusion layer on the surface of the chip.
7.LED sintering
The purpose of sintering is to cure the silver paste, and the sintering requires monitoring of the temperature to prevent batch defects. The temperature at which the silver paste is sintered is generally controlled at 150 ° C and the sintering time is 2 hours. According to the actual situation, it can be adjusted to 170 ° C for 1 hour. The insulating glue is generally 150 ° C for 1 hour.
The silver-glued sintering oven must be opened and replaced with a sintered product within 2 hours (or 1 hour) according to the process requirements, and should not be opened at will. Sintering ovens must not be used for other purposes to prevent contamination.
iPhone 4S Battery 3.7V Li-ion with 500 cycle life time which is make from brandnew cell and high quality protection board and FPC,all the raw materials is customerized. 0 cycle and iPhone 4S Battery life more than 500 times, rejection rate under 3‰. We are professional manufacturer on iPhone battery.
Nominal voltage: 3.7V
Limited charge voltage: 4.2V
Capacity:1430mAh (5.3whr)
Cell size: 42x32x82mm
iPhone 4S Battery
iPhone 4S Battery,iPhone battery,iPhone 4S Battery life,iPhone 4S Battery Pack
Shenzhen Aokal Technology Co., Ltd. , https://www.aokal.com