SURFACE STRESS METER

**Surface Stress Meter for Tempered Glass (Ref. ASM-100-3)** The Surface Stress Meter is specifically designed to measure the compressive stress on tempered glass surfaces. It uses a light beam that spreads across the surface of the glass, and through the photoelastic principle, it calculates both the surface stress value and the depth of the stress layer. A computer is integrated into the system to minimize measurement errors and support data management. This device can be operated manually or automatically, offering flexibility depending on the condition of the sample. Optional accessories such as an automatic titrator and thickness gauge are available to enhance efficiency and accuracy. **FEATURES** 1. Unique Measurement Principle: Photoelastic Analysis Refractometer 2. Automated Testing to Reduce Human Error 3. Computer System for Data Storage and Quality Control 4. Manual Mode Available for Samples with Poor Tempering Conditions 5. LED Light Source with 10,000-Hour Lifespan 6. Masterpiece for System Self-Calibration 7. Automatic Judgment of Pass/Fail Based on Operator Settings During Continuous Testing 8. Real-Time Display of Test Results and Number of Tests During Continuous Operation 9. Option for Single and Manual Measurement 10. Automated Immersion Drop Function Controlled by Special Software to Minimize Immersion Liquid Usage **SPECIFICATIONS** - **Stress Measurement range (MPa):** 1–1000 - **Stress measurement accuracy (MPa):** ±20 - **Depth measurement range (µm):** 0–200 - **Depth measurement accuracy (µm):** ±5 µm - **Measurement object:** Chemically and physically tempered glass - **Measurement area (mm):** ≥12 × 7 - **Measurement principle:** Photoelastic Analysis via Refractometer - **Light source:** Special LED (wavelength: 590 nm ± 10) - **Refractive index of prism:** 1.72 - **Computer:** Dedicated OS and software (pre-installed) - **Software:** Specialized ASM-100-3 software - **Power supply:** AC 220V, 3A - **Air source (MPa):** 1 (clean air) - **Weight (measuring head):** Approximately 14 kg **INCLUDED ITEMS** 1. Measuring Head: 1 set (ASM-100-3) 2. Prism (12 × 7 mm): 1 set (installed on measuring head) 3. Computer (Dell): 1 set 4. Dongle: 1 set (inserted into computer) 5. ASM Measurement Software: 1 set (pre-installed on computer) 6. Immersion Liquid: 20 ml 7. Masterpiece: 1 set 8. XP Operating System 9. User Manual: 1 set (in Chinese version) 10. Liquid Titrator: 1 set This instrument is ideal for quality control in industries that rely heavily on tempered glass, such as automotive, architectural, and electronics manufacturing. Its combination of precision, automation, and user-friendly design ensures reliable results while reducing operational costs and improving workflow efficiency.

Aluminum Frame LV 3PH Asynchronous Motor

Aluminum Frame Lv 3Ph Asynchronous Motor,Three-Phase Asynchronous Motor,3 Phase Asynchronous Induction Motor,Aluminum Frame Three Induction Motor

Yizheng Beide Material Co., Ltd. , https://www.beidevendor.com

Posted on