In several second-hand household appliance trading markets, operators have not agreed on warranty periods and warranty obligations when selling second-hand TVs, washing machines, and refrigerators, and some second-hand computers have only one month warranty. "After the implementation of the "Measures," the past buying, pricing, and transaction methods will change and form a new transaction model." Mr. Wang, who has been engaged in the recycling business of old appliances for many years in the foreign goods market, told reporters.
Many second-hand home appliances have been labeled with “salesâ€. A 29-inch old TV was sold for 300 yuan last month and is now sold for 240 yuan. Another 70 litre freezer is not only cheaper for 50 yuan, but also a 15-litre small refrigerator. One operator stated that many second-hand household electrical appliances in stock were “three nothing†goods. They did not request the original purchase vouchers, did not register product information, and did not create file information. If they were not dealt with as soon as possible, the new regulations may be imposed after implementation. 2,000 yuan up to 10,000 yuan fine. In addition, some household appliances that are too old may not have sold as much money. If they provide free warranty service for no less than three months, they will have to outweigh the gains. Therefore, before the implementation of the new regulations, they will quickly cut prices and sell them.
At the same time, as the price cuts for second-hand household appliance price cuts and housing leasing markets usher in the peak season, the number of people who come to the second-hand home appliance market to “wash†the goods has gradually increased, and sales of old home appliances have increased significantly. A second-hand appliance company told reporters that it is now possible to sell several pieces of old appliances every day, and the transaction volume has nearly doubled from the original.
In response, Bai Yuhua, vice president of the Tianjin Electronic and Electrical Product Maintenance Industry Association, reminds consumers not to blindly buy “three-nothing†used home appliances because they are difficult to guarantee because of the hidden dangers of security.
Aerial Insulated Cables Within Rated Voltage Up To Including 0.6/1KV
1. Product standard
The product is manufactured according to the standards of GB12527-90 [Aerial insulated cables of rated voltages up to and including 1KV" and IEC60502 [Extruded solid dielectric power cables for rated voltage from 1KV to 30KV" .
2. Operating characteristics
a. Rated voltage U0/U: 0.6/1kV
b. Max.permissible continuous temperature:
PVC.PE insulated aerial cables:70℃
XLPE insulated aerial cables:90℃
c. Max. short-circuit temperature of the conductor shall not exceed:
PVC insulated aerial cables:160℃;
PE insulated aerial cables:130℃;
XLPE insulated aerial cables:250℃.
d. The installation ambient temperature should not below -20℃.
The bending radiuses of cables are recommended as follows:
When the diameter of cables less than 25mm: not less than 4 times the diameter of cables;
When the diameter of cables not less than 25mm: not less than 6 times the diameter of cables.
e. When the cables use in alternating current system, rated voltage of cables should be at least equal the rated voltage of the system; When the cables use in direct current system, rated voltage should be not greater than 1.5 times of the rated voltage of the cables.
3. Type of cables and main usage
Type of cable:
JKV: Copper conductor PVC insulated aerial cables
JKLV: Aluminum conductor PVC insulated aerial cables
JKY: Copper conductor PE insulated aerial cables
JKLY: Aluminum conductor PE insulated aerial cables
JKYJ: Copper conductor XLPE insulated aerial cables
JKLGV: ACSR conductor PVC insulated aerial cables
JKLGY: ACSR conductor PE insulated aerial cables
JKLGYJ: ACSR conductor XLPE insulated aerial cables
Main usage:
The cables fit for overhead fixed-installation, service line and so on.
4. Construction of cable
1) Conductor
2) Steel core
3) Insulation
4) Conducor screen
Steel ACSR Power Cable,Hot Dip Galvanized Power Cable,Conductor Power Cable,Overhead Power Cable
Huayuan Gaoke Cable Co.,Ltd. , https://www.bjhygkcable.com