Programmable high-definition (HD) video and imaging platform CEVA-MM3000 (CEVA)
CEVA released the fully programmable high-definition (HD) video and imaging platform CEVA-MM3000, which is designed for the next generation of connected portable multimedia and home entertainment devices. CEVA will showcase the CEVA-MM3000 platform at a media conference in Beijing.
The low-power platform is based on a heterogeneous (heterogeneous), scalable multi-core architecture, capable of decoding and encoding full HD 1080p video at a frame rate of up to 60fps (frames per second), supporting H.264, VC1, Real Video, Advanced video standards such as AVS and VP6 / 7/8, as well as future standards such as Scalable Video Codec (SVC) and Multi-window Video Codec (MulTI-view Video Codec, MVC) for 3D video . In addition to augmented reality, gesture recognition, and face detection, a variety of unique add-on applications (proprietary add-on applicaTIons), CEVA-MM3000 also supports video and image pre / post-processing algorithms, such as scaling, anti-processing Shaking and noise reduction. Crucially, these additional algorithms and unique applications implemented by CEVA-MM3000 allow designers to reach new levels in multimedia innovation and performance, while reducing or even eliminating those commonly used in multimedia SoCs to handle these Complicated engine.
Multi-core architecture designed for low power consumption and easy programming
As a unified and coherent structure, CEVA-MM3000 uses a multi-core heterogeneous method to meet the extreme and variable processing requirements in video and image signal processing. The core of the platform contains two dedicated processors, a Stream Processor and a Vector Processor, all of which constitute a complete multi-core system, including local and shared memory, peripherals, DMA and Standard bridge to external bus. This complete (comprehensive, integrated) multi-core platform is designed to meet the low power requirements of mobile devices. For example, H.264 HP decoding at 1080p 30fps requires power consumption as low as 150mW when using 40nm process devices.
The stream processor is responsible for code stream encoding, code stream operation, and control code execution, while the vector processor performs filtering and vector operations for pixel processing. Both the stream processor and the vector processor are designed for easy programming and are supported by an optimized C compiler and an application profiler (applicaTIon profiler). CEVA can provide authorized manufacturers with a set of pre-optimized video cores for the above two processors to achieve the flexibility of combining efficient low-level code with rapid C-level development.
Linby Group analyst Joseph Byrne, author of "CPU Core and Processor IP Guide" said: "Consumer demand for higher video quality and richer functionality seems to be endless. CEVA-MM3000 is a flexible, scalable, The robust software-based platform can meet the requirements of consumer electronics products. In the past, the realization of 1080p video engines required hardware design and implementation. CEVA-MM3000 subverted that traditional way with a unique concept. The programmable feature of this architecture, Not only can it efficiently support the video standard, but it can also implement the next-generation features such as customer-specific post-processing algorithms and object recognition (object recogniTIon). "
Gideon Wertheizer, CEO of CEVA, said: "The arrival of 4G wireless networks and the rise of connected homes will completely change the way people access and watch multimedia content. 1080p HD is gradually becoming the de facto standard for various multimedia devices. Support for increasing number of video codecs is required. The high-performance, multi-core, scalable structure of CEVA-MM3000 is a software-only, low-power, and cost-effective platform that provides performance and flexibility that meets these needs, and is applicable For any networked multimedia device. In addition, the unique video and image pre / post-processing algorithm support allows authorized vendors to achieve unique differentiation of their video processor designs with unique features and functions. "
Scalability and programmability enable a large number of optimized applications
In order to efficiently meet the precise requirements of a wide range of portable multimedia and home entertainment applications, CEVA-MM3000 uses a scalable heterogeneous (heterogeneous) architecture. The type and capacity of the memory, as well as the number of stream processors and vector processors, are configurable to meet the requirements of each specific application case. This scalability allows the CEVA-MM3000 to provide the best balance of power consumption and performance to meet smartphones, PMPs, tablets and other mobile devices, as well as Blu-ray DVD players, HDTVs, game consoles and Full HD performance requirements for multi-stream devices.
As a fully programmable engine, CEVA-MM3000 can easily support any codec or other video processing software. This programmability enables SoC designers to quickly adopt new video standards through software upgrades without changing the hardware design, and can easily develop unique video and imaging applications, including pre / post-processing and video analysis. This flexibility can extend the product life cycle, achieve design reuse, and allow customers to use non-standard imaging or unique algorithms to achieve product differentiation.
Main features of CEVA-MM3000
· The industry's highest performance HD video and image processing platform for networked devices
· Supports the most advanced video codecs and profiles, including H.264, VC1, Real Video, AVS, VP6 / 7/8, up to 1080p 60fps.
· The architecture supports future standards such as MVC (3D), SVC and H.265
· Use the same platform for 1080p H.264 HP encoding
· Heterogeneous, multi-core architecture optimized for video and image signal processing
· Stream processor – responsible for code stream encoding, code stream operation and control code execution
· Vector processor – deep SIMD processor for parallel filtering and pixel processing
· Scalability and configurability
· The same architecture can be expanded from 720p to 1080p 60fps, from 6Mbps to 50Mbps
· The number and type of vector processors and stream processors are scalable
· Configure memory capacity based on required performance
· Support multi-stream decoding, transcoding and video conference
· Multi-purpose platform to meet different video / image processing needs
Support pre- / post-processing algorithms such as scaling, mirroring, white balance, noise cancellation and DRC
Support intelligent video processing such as augmented reality, gesture recognition, face and target recognition
· Integrated software development tools
· Compiler, multi-core debugger, emulator, etc. for each core and the entire system
· Rich pre-optimized video kernel and filter library
· Easy to upgrade to support any codec / standard software developed by CEVA, third parties and customers
Development tools and support
Like all DSP core and platform solutions of CEVA, CEVA-MM3000 is supported by a powerful software development tool suite, including optimized C compiler, IDE (integrated development environment), debugger, emulator and profiler. It comes with a user-friendly integrated development environment (IDE) to help developers execute, debug, optimize, and run code on the CEVAMM3000. To assist with vector processor optimization, the IDE provides a view of all core and memory resources. The IDE also includes a multi-core debugger GUI (graphical user interface) for visualizing stream processors and vector processors. In addition to helping to find software vulnerabilities, this debugger can also assist performance analysis and optimization. CEVA also provides optimized video core libraries, enabling authorized manufacturers to develop applications quickly and easily.
Supply
Currently, CEVA-MM3000 is only authorized for use by leading customers. For more information, please send an email to.
To learn more about CEVA-MM3000, please visit: HD.
About CEVA
CEVA is headquartered in San Jose, California, USA, and is a professional leading licensee that provides silicon intellectual property (SIP) DSP cores and platform solutions to mobile phones, portable devices, and consumer electronics markets. CEVA's IP series includes cellular baseband (2G / 3G / 4G), multimedia, high-definition (HD) audio, voice over packet (VoP), Bluetooth (Bluetooth), Serial Attached SCSI (SAS) and Serial ATA (SATA) and other comprehensive and comprehensive technologies. In 2009, more than 330 million products using CEVA's IP technology were shipped, including mobile phones produced by the top five OEMs (Nokia, Samsung, LG, Motorola, and Sony Ericsson). Today, more than one in four mobile phones shipped worldwide uses CEVA DSP cores.
Being a quality-focused organization, we are engaged in manufacturing and supplying Polycrystalline Solar Panels that are in conformation with the industry standards. We make use of polycrystalline silicon, which is a brilliant semiconductor. Moreover; Polycrystalline Solar Panels have an average life of fifty years. We offer Polycrystalline Solar Panels that are available at market leading prices.Solar panels are consist of arrays formed by small sized solar cells, they come in different sizes and shapes. This versatility in sizes makes it possible to installed them wherever it can receive direct and maximum sunlight for optimum performance, i.e. land or roof. Solar cells can also be installed skylights or vertical walls
Poly 200W Solar Panel,200W Solar Panel,200 Watt Solar Panel
Yangzhou Bright Solar Solutions Co., Ltd. , https://www.solarlights.pl