Chen Yansheng, chairman of the China Lighting Association, said that if China uses all such LED lights, it is equivalent to a reduction of 311 billion tons of CO 2 per year, and the electricity saved is equivalent to the total power generation of 3.1 Three Gorges Dams a year.
Upstream and downstream to replace halogen lamps
Recently, Sharp announced that it has taken LED brightness, color quality and consistency to a new level, and took another step towards the goal of completely replacing high-energy halogen light sources. It can achieve the same brightness as halogen bulbs, with a color rendering index of 95 or higher. The new chip has higher brightness, unparalleled light color quality and proven lighting level reliability. Jin Luming is the first in the series and has achieved excellent results. Lighting effect.
Zhu Dongliang, Chairman of Jinluoming Co., Ltd. said: "The first-class color-quality chip is a necessary condition for ensuring high-performance lighting solutions for Jin Luming's LED lamps. Jin Luming and halogen lamps are exactly the same color and brightness, combined with the efficiency of LEDs. The energy-saving advantage will definitely lead to fundamental changes in the market."
Jin Luming's LED lamp adopts CAMETA TM patented lens, which has the outstanding features of “light source anti-glare, soft light, natural light colorâ€, which achieves almost the same brightness and natural light distribution of halogen lamp, anti-glare performance. Especially outstanding.
The most obvious alternative to halogen lamps is the economic benefits. Compared with halogen lamps, Jin Luming's LED lamps developed on the basis of Sharp chips are more than 90% energy-efficient compared to halogen lamps.
70W halogen lamp and LED lamp are actually measured during the use of the parameters for comparison.
Parameter type | Actual power W | Luminous flux LM | Light effect LM/W | life H |
Halogen lamp 70W | 70 | 980 | 14LM/W | 2000 |
Loading luminaire | 630 | 9LM/W | ||
LED energy saving lamp 9W | 10W | 1000 | 100LM/W | 40000 |
Compared with the light effect, the LED energy-saving lamp is 6 times that of the halogen lamp . However, after the lamp is installed, most of the light of the halogen lamp needs to be reflected by the lamp, and a part of the light is lost when reflected, and the LED light source directly passes through the optical stage PMMA . The light material can be determined according to the range / distance of the illumination , and there is no problem of additional light loss. Therefore, the LED energy-saving lamp is 8.5 times that of the halogen light , that is, under the same power, the LED energy-saving lighting effect is 8.5 of the brightness of the halogen lamp. Times.
Fuse refers to an electric appliance that, when the current exceeds the specified value, melts the fuse and disconnects the circuit with the heat generated by itself.When the current exceeds the specified value for a period of time, the fuse melts and disconnects the circuit with the heat generated by the fuse itself.A current protector made from this principle.The fuse is widely used in high and low voltage power distribution system and control system as well as power equipment.
Ferrite is a metal oxide with ferrous magnetism.As far as electrical properties are concerned, the resistivity of ferrite is much larger than that of single metal or alloy magnetic materials, and it has higher dielectric properties.Ferrite magnetic energy also shows high permeability at high frequencies.As a result, ferrite has become a non-metallic magnetic material widely used in the field of high frequency and weak current.Due to the low ferrite magnetic energy stored in the unit volume, saturated magnetic induction strength (Bs) and low (usually only pure iron 1/3 ~ 1/5), and thus limits its higher requirements in the low-frequency magnetic energy density in the field of high voltage and high power applications.
Semiconductor Fuse and Ferrite
Semiconductor Fuse, Fuse Cutout, Protection Fuse, Square Fuse, Fuse Link, Ceramic Fuse, Fuse Box, Fuse Resistors
YANGZHOU POSITIONING TECH CO., LTD , https://www.yzpstcc.com