The following provides a reference design for automotive LED systems. Use the MAX15005 to boost an 8V to 16V automotive battery to 21V to drive a string of 6 to 8 LEDs.
The key parameters of the reference design are listed below, and the required detailed circuit schematic (Figure 1) and bill of materials (Table 1) are given.
Specifications VIN: 8V to 16V (continuous), 40V (transient) VLED + supply voltage: 21V ± 5% at 80mA (maximum) VLED + load range: 10V to 20V at 70mA ILED: 70mA ± 5% brightness adjustment input: 400Hz, 50Ω , Open collector brightness adjustment resolution: 3µs Switching frequency: 385kHz Operating temperature: -40 ° C to + 125 ° C
Detailed drawing (PDF, 92kB)
Figure 1. MAX15005 reference design
Table 1. List of materials
Designator | Value | DescripTIon | Part | Footprint | Manufacturer | QuanTIty |
C1, C5, C6, C8, C10 | 1µF / 50V | Capacitors | GCM31MR71H105KA55L | 1206 | Murata | 5 |
C2 | 200pF / 100V | Capacitor | GRM2165C2A201JA01D | 0805 | Murata | 1 |
C3, C13, C14 | 100nF / 100V | Capacitors | GCM21BR72A104KA37L | 0805 | Murata | 3 |
C4, C7, C9 | 100pF / 50V | Capacitors | GRM2165C1H101JA01D | 0805 | Murata | 3 |
C11 | 10nF / 50V | Capacitor | GRM216R71H103KA01D | 0805 | Murata | 1 |
C12 | 10µF / 50V | Capacitor | UUD1H100MCL1GS | SMD | Nichicon | 1 |
D1 | 1A / 400V | Diode | S1G | SMA | Fairchild | 1 |
D2 | 200mA / 100V | Schottky diode | BAT41ZFILM | SOD123 | STM | 1 |
D3 | 200mA / 30V | Schottky diode | STM | SOT23 | STM | 1 |
L1 | 470µF / 0.86A | Inductor | MSD1260-474 | SMD | Coilcraft | 1 |
Q1 | 1A / 100V | n-FET | ZXMN10A07Z | SOT89 | Zetex | 1 |
Q2 | 2A / 55V | n-FET | IRLL014NTRPBF | SOT223 | InternaTIonal RecTIfier | 1 |
Q3 | 220mA / 50V | n-FET | BSS138 | SOT23 | Fairchild | 1 |
R1 | 22.1kΩ | Resistor | SMD, 1%, 0.125W | 0805 | Vishay | 1 |
R2, R4, R6 | 100kΩ | Resistors | SMD, 1%, 0.125W | 0805 | Vishay | 3 |
R3 | 26.7kΩ | Resistor | SMD, 1%, 0.125W | 0805 | Vishay | 1 |
R5 | 6.19kΩ | Resistor | SMD, 1%, 0.125W | 0805 | Vishay | 1 |
R7 | 3.65kΩ | Resistor | SMD, 1%, 0.125W | 0805 | Vishay | 1 |
R8 | 210kΩ | Resistor | SMD, 1%, 0.125W | 0805 | Vishay | 1 |
R9, R16 | 2kΩ | Resistors | SMD, 1%, 0.125W | 0805 | Vishay | 2 |
R10 | 10Ω | Resistor | SMD, 1%, 0.125W | 0805 | Vishay | 1 |
R11 | 100Ω | Resistor | SMD, 1%, 0.125W | 0805 | Vishay | 1 |
R12 | 8.66kΩ | Resistor | SMD, 1%, 0.125W | 0805 | Vishay | 1 |
R13 | 0.51Ω | Resistor | Sense resistor | SL1 | Vishay | 1 |
R14 | 1.4kΩ | Resistor | SMD, 1%, 0.125W | 0805 | Vishay | 1 |
R15 | 100Ω | Resistor | SMD, 1%, 0.125W | 0805 | Vishay | 1 |
R17 | 10Ω | Resistor | SMD, 1%, 0.205W | 1206 | Vishay | 1 |
IC1 | MAX15005A | Boost controller | MAX15005AAUE + | 16-TSSOP-EP | Maxim | 1 |
IC2 | MAX4400 | Single op-amp | MAX4400AXK + | 5-SC70 | Maxim | 1 |
The oscilloscope screenshots in Figures 2, 3, and 4 show the switching waveforms at three different dimming inputs.
Figure 2. ILED waveform measurement with VIN = 14V and 50.0% dimming ratio
Figure 3. ILED waveform measurement with VIN = 14V and 0.1% dimming ratio
Figure 4. ILED waveform measurement with VIN = 14V and 99.9% dimming ratio
PCB Assembly = Printed Circuit Board Assembly, which means to assemble the electronic components on blank printed circuit boards. After assembly done, the components would be connected together through the copper circuits on PCB .
Depends on the components assembly types, it have THT PCB assembly, SMT PCB Assembly , one sided SMT and THT PCB assembly, two sided SMT and THT PCB assembly.
Depends on the PCB type, it have Rigid PCB Assembly, Flex PCB Assembly and Flex-Rigid PCB Assembly.
Also we would call some PCB assembly types as Prototype PCB Assembly, Mass PCB Assembly , Turnkey PCB Assembly, LED PCB Assembly and BGA PCB Assembly , etc.
With our 15years professional experience, we are available for all types of PCB assembly service from prototype to mass production, available for 01005, 0201, 0.3mm BGA, 0.3mm QFP.
PCB Assembly Capabilities
Quantity |
1 pcs - 1,000,000 pcs |
Assembly type |
SMT, THT or Hybrid |
Parts procurement |
Full turnkey (ZhongFeng provide all components) |
Partial turnkey ( Customer provide the main components and ZhongFeng provide the rest) |
|
Kitted (Customer provide all components) |
|
Component types |
SMT 01005, 0201, BGA 0.3mm pitch, QFP 0.3mm pitch, etc. |
Test |
Visual Inspection, AOI, Custom testing, ICT, FCT, Test jig |
PCB Assembly Products Show
PCB SMT Assembly Factory Show
PCB Assembly
PCB Assembly,PCB Assembly Services,Electronic PCB Assembly,PCB SMT Assembly
ZhongFeng Electronic Technology Co., Limited , https://www.dopcba.com